X10CONFIG(5)		      File Formats Manual		  X10CONFIG(5)

NAME
       x10config  -  Configuration  file format	for HEYU, an X-10 CM11A	serial
       interface control program

DESCRIPTION
       Heyu is a program for controlling an X-10 "CM11A" home control  device.
       See  the	heyu(1)	man page for usage information.

       The  configuration file contains	several	critical pieces	of information
       that the	heyu program needs in order to function, plus a	number of user
       options.	 These are all specified by keywords known as directives which
       are explained below.  In	general, directives may	appear in any order in
       the  configuration  file,  however see the exception to this rule under
       the heading for the ALIAS directive.

       The configuration file, named x10config,	 is  normally  stored  in  the
       (hidden)	  subdirectory	 .heyu	 under	 your  home  directory,	 i.e.,
       $HOME/.heyu/x10config

       For system-wide use, the	configuration file may alternatively be	stored
       as file x10.conf	in the directory /etc/heyu (or as otherwise defined in
       Configure for your operating system).

       The configuration file may be located  in  an  additional  subdirectory
       level  under either of the directories above.  The additional subdirec-
       tory level can have a name of your choice,  for	example	 "mysub".   In
       this  case  you	must  specify  the  name  of the subdirectory with the
       HEYUSUB environment variable in order for Heyu to find it, for  example
       HEYUSUB=mysub.  Somewhat	 more convenient however is to locate the con-
       figuration file	in  a  subdirectory  named  simply  /0	...  /9,  e.g.
       $HOME/.heyu/3/x10config,	in which case Heyu can be instucted to use the
       appropriate directory with the command line option '-0' ... '-9'.

       Finally,	the configuration file may be stored in	any arbitrary location
       on  your	 hard drive with any arbitrary filename, but the full pathname
       will have to be specified either	with the '-c' Heyu command line	option
       or with the X10CONFIG environment variable.

       If the HEYUSUB environment variable is NOT set or the '-0' ... '-9' not
       specified, then the search will start  with  $HOME/.heyu/x10config  and
       continue	with /etc/heyu/x10.conf, stopping with the first one it	finds.
       If not found, Heyu will exit with an error message.

       If the HEYUSUB environment variable IS set or  the  '-0'	 ...  '-9'  is
       specified,  the	search	for  the  configuration	 file  will start with
       $HOME/.heyu/<subdirectory>/x10config, then, if not found, will continue
       looking for /etc/heyu/<subdirectory>/x10.conf. Examples:
	  $HOME/.heyu/mysub/x10config
	  /etc/heyu/mysub/x10.conf
	  /etc/heyu/4/x10.conf

       If not found under either of these places, Heyu will exit with an error
       message.

       (The main reason	for implementing the subdirectory feature is to	enable
       Heyu  to	 be used for more than one CM11A interface, with separate con-
       figuration and other files for each.  If	you have only one CM11A	inter-
       face, you probably won't	find a need to bother with it.)

       The  directory  in  which  the  configuration  file  is located MUST be
       writable	by Heyu.

       Case sensistivity:
       The following entities ARE case-sensitive: Filenames; Pathspecs;	Serial
       ports (and the keyword "dummy" used when	there is no CM11A connected);
	Heyu  and  shell commands; Alias, Scene, Usersyn, Script, and Launcher
       labels.

       The following entities are NOT case sensitive:  Names of	directives and
       values of directives other than those listed above; Housecode letters.

TTY directive
       The  TTY	 directive  is	the most important.  Syntax is simply the word
       TTY, a space and	then the full path name	for the	serial port  to	 which
       the CM11A is attached.  /dev/ttyS0 would	be the first serial port (cor-
       responding to COM1 under	MS-DOS).  /dev/cua0 will also work.
       Examples:

	  TTY /dev/ttyS0
	  TTY /dev/cua2
	  TTY /dev/usb/ttyUSB0	(implies a USB-Serial adapter)

       To configure Heyu for a CM10A interface (instead	of a CM11A  or	CM12),
       append the keyword "CM10A", e.g.:

	  TTY /dev/ttyS0  CM10A

       Note: If	you've started Heyu before configuring for the CM10A, you must
       stop and	start it up again.  I.e., 'heyu	stop', then 'heyu start'.

TTY dummy directive
       Setting the directive
	  TTY dummy
       tells Heyu there	is no CM11 powerline interface connected and Heyu com-
       mands  which attempt to communicate with	the interface will result in a
       quick error message.  However commands which involve only the  heyu_en-
       gine  and heyu_aux daemons will continue	to function, e.g., setting and
       reading flags or	countdown timers, and executing	scripts	launched by RF
       signals	forwarded  from	heyu_aux. (Like	the name of the	serial port it
       replaces, the word "dummy" is case sensitive.)

HOUSECODE directive
       The housecode directive indicates the housecode for which the CM11A  is
       to  store in its	internal registers the on/off/dim status of individual
       units when signals are sent or received over the	AC  power  line.   The
       'heyu  reset'  command (with no housecode parameter supplied) will pro-
       gram the	CM11A to use the housecode provided by	this  directive.   (It
       will not	do this	automatically.)

       Example:
	  HOUSECODE   D

       The default for this directive is housecode A.

ALIAS directive
       An  alias  associates a label (front_porch) with	an X10 device (A10) so
       that we don't have to remember that the front porch light is house code
       A, device 10.  In other words, we can use a mnemonic to represent a de-
       vice.

       There are a few other directives	in which the user may choose to	refer-
       ence an alias label in place of a housecode|unitcode address.  In these
       cases the alias directive must appear before the	other directive	in the
       configuration file in order to be resolved.  Therefore it's a good idea
       to group	all the	alias directives at or near the	beginning of the file.

       Alias labels can	refer to one or	more X10 devices with the same housec-
       ode,  however  Heyu's  monitor will display the alias label only	if the
       alias references	a single device	address.

       The format for an alias is:
	  ALIAS	 Label	Housecode|Devices  [Module_type	[Module	option]]
       where the Housecode letter and Device string are	concatenated.

       Label can be any	contiguous string (maximum length  32  characters)  of
       alphanumeric  characters	 or period '.',	hyphen '-', or underscore '_',
       except that the the hyphen and underscore may not be the	first  charac-
       ter in the string.  The label may not be	the word 'macro'.

       Alias labels are	case sensitive,	so that	'kitchen' and 'Kitchen'	repre-
       sent two	distinct aliases.
       Housecode is a case-insensitive letter A-P (or a-p).
       Devices can be 4	things:

	      1. A single number (example 1)
	      2. A group of numbers separated by commas	(example 1,2,14,15)
	      3. A range separated by a	dash (example 1-8)
	      4. A combination of 2 and	3 (example 1-8,14,15)

       Module_type is optional and defines for Heyu the	attributes of the par-
       ticular kind of module assigned to the Housecode|Unit.
       Heyu uses this information to determine what state the module should be
       in when the module receives any particular command. E.g., it will  know
       that an appliance module	will never be in a dimmed state	even though it
       may be sent a dim command.

       Unlike many popular software programs which attempt to do your thinking
       for  you,  Heyu	does  not decide what X10 command to send based	on the
       Module_type defined for the specific housecode|unit address  or	alias.
       It  does	 only  what you	tell it	to do, and defining a Module_type does
       not restrict Heyu from sending a	command	which the module may not  sup-
       port.   E.g.,  if  you  tell Heyu to send a dim command to an appliance
       module, it will do so without question.	But the	physical  module  will
       not respond and the Heyu	state will reflect that	fact.

       The  following  generic	module types and/or specific model numbers are
       currently recognized.  The names	are not	case-sensitive:

		 *** WARNING - WARNING - WARNING ***

       The X-10	LM465 Lamp Module and WS467 Wall Switch	Module were redesigned
       in  2007	 but the model numbers,	appearance, and	packaging remained un-
       changed.	The new	designs, designated here as module types  LM465-1  and
       WS467-1,	 have  quite  different	 features and characteristics from the
       original	designs. Among other differences, they support a subset	of Ex-
       tended Code commands.  They can be distinguished	by executing 'heyu xon
       Hu' and 'heyu xoff Hu' at the command prompt.  The  redesigned  modules
       will  respond  and  turn	 respectively On and Off; the original modules
       won't respond.

       Among the potential problems, there's an	apparent design	error  in  the
       redesigned  WS467 Wall Switch firmware making it	not backwards compati-
       ble with	the original design.  A	standard X10 bright  or	 dim  or  dimb
       signal  won't  turn  it	On from	the Off	state unless preceded by an on
       signal.

	  LM465-1 (LM-1) - Redesigned LM465 lamp module.
	  LM	(StdLM LM465 PLM01 PLM03) - Original standard X-10  lamp  mod-
       ule.
	  LM12	() - Marmitek standard X-10 lamp module.
	  LMS	(?) - X-10 2-way lamp module (responds status on/off).
	  AM	(StdAM AM486 AM466 PAM01 PAM02)	- Standard X-10	appliance mod-
       ule.
	  AM12	() - Marmitek standard X-10 appliance module.
	  SR227	(PA011)	- X-10 socket module.
	  AMS	(RR501 PAT01) -	X-10 2-way switch (responds status on/off).
	  Some 2-way modules can be configured to automatically	return a  Sta-
       tusOn/Off
	  whenever they	are turned On/Off.  For	these, the module type parame-
       ter
	  "DEFER" instructs Heyu not to	update the stored states of the	module
       with
	  the  On/Off  signal  but  let	the ensuing StatusOn/Off signal	do it.
       (Otherwise
	  the changed state following the StatusOn/Off	would  always  be  un-
       changed.)
	  RAIN8II () WGL model Rain8II 2-way irrigation	controller which
	  can  be configured to	automatically respond with a StatusOn/Off sig-
       nal
	  when turned On/Off.
	  WS467-1 (WS-1) - Redesigned WS467 wall switch	module.
	  WS	(StdWS WS467) -	Standard X-10 wall switch module.
	  LW10U	 () - Marmitek dimming wall switch module.
	  WS12A	 (XPD3)	- X-10 dimming wall switch module.
	  WS13A	 (XPS3)	- X-10 non-dimming wall	switch module.
	  LM15A	(PSM04)	- X-10 Socket Rocket screw-in non-dimming lamp module.
	  LM15	() - Marmitek screw-in non-dimming lamp	module.
	  AM14A	(AM15A PAM21 PAM22) - X-10 2-way  appliance  module  (Extended
       codes).
	  LM14A	(PLM21)	- X-10 2-way lamp module (Extended codes).
	  SL1AM	(?) - SwitchLinc 1-way switch (Preset codes).
	  SL2AM	(?) - SwitchLinc 2-way switch (Preset codes).
	  SL1LM	(?) - SwitchLinc 1-way dimmer (Preset codes).
	  SL2LM	(SL2380W) - SwitchLinc 2-way dimmer (Preset codes).
	  LL1LM	(?) - LampLinc 1-way dimmer (Preset codes)
	  LL2LM	(LL2000STW) - LampLinc 2-way dimmer (Preset codes)
	  RS114	() ACT user-programmable 2-way switch module.
	  With this module, support for	AllUnitsOff, AllLightsOn, and
	  AllLightsOff signals is user programmable.  Module type parameters
	  AUF,	ALO,  and  ALF match Heyu's support with the module's program-
       ming.
	  RF234	() ACT user-programmable 2-way switch module.  This 230V
	  module has similar to	but not	 identical  characteristics  with  the
       RS114.
	  Based	on data	from a single device, it appears the RS234 does	not
	  maintain its address after being turned On or	Off.
	  AMEXC16 (?) -	Module of the appliance	type with
	  exclusive addressing:	An on command turns On only the	last
	  unit addressed.  All other modules of	this type on the
	  same housecode turn themselves Off and become	unaddressed.
	  AMEXC8 (RAIN8) - Modules of the appliance type with
	  exclusive addressing within groups of	8 units, i.e., 1-8,
	  9-16.	Other modules on the same housecode and	within the same
	  group	of units turn themselves Off when the last addressed
	  unit in that group is	turned On.  A typical device of	this
	  type is the WGL Rain8	Irrigation Controller.
	  AMEXC4 (XM10A	XM13A) - Similar to AMEXC8 but with
	  exclusive addressing within groups of	4, i.e., 1-4,
	  5-8, 9-12, 13-16.  Typical modules of	this type are X-10's
	  XM10A	and XM13A camera power supplies.
	  PR511	() - X-10 PR511	2-way Motion Sensing floodlight
	  NONE	- No module; supports no X10 commands.
	  REMOTE2 - Not	actually a module, it can be used as
	  a 'target' for X10 commands sent by a	transmitter
	  with only On/Off codes (like a keychain remote
	  or motion sensor), when there	is no physical module
	  assigned to that Housecode|Unit.
	  REMOTE4 - Like the above, but	for a four function
	  transmitter like a PalmPad which can send Dim	and
	  Bright codes in addition to On and Off.
	  REMOTE6 - Like the above, but	for a six function
	  transmitter like the Mini- or	Maxi-Controller	which
	  can send On, Off, Dim, Bright, LightsOn, and AllOff
	  codes.

	  Note that the	above two REMOTEs function a little
	  differently than lamp	modules.  The state for	an On
	  (or a	LightsOn for REMOTE6) code will	always be
	  recorded as fully On regardless of prior state,
	  and the state	for Dim/Bright codes can range from
	  fully	Off through fully On and vice-versa.  This
	  allows their use in scripts for controlling things
	  other	than modules.

	  REMOTE3 - Similar to REMOTE4 except that the On
	  command is ignored by	the state engine except	for
	  addressing the particular unit in the	housecode -
	  it does not change the stored	brightness level.
	  The Off command does set the brightness level	to
	  zero and the Bright and Dim commands make incremental
	  changes in this level	within the range fully Off
	  to fully On.	(The Bright and	Dim signals sent by
	  RF remotes do	not include a unit code.  This module
	  type allows using the	On signal to address a
	  particular unit without changing the stored brightness
	  level	and then using the Dim and Bright commands for
	  some analog control purpose via a script.)

	  REMOTEP - Again not actually a module, but can be
	  used as a target for transmitters which send only
	  the Preset (1-32) codes.

	  SHUTTER (SW10) - Shutter and shade controller
	  which	support	Extended Code Type 0 commands. The
	  Marmitek SW10	Shutter	Motor Controller is the	only
	  module known to support these	commands and Marmitek
	  keeps	it a secret.  This Heyu	model supports Extended
	  Type 0 functions 0x01, 0x02, 0x03, 0x04, and 0x0B.
	  The Heyu model also supports the standard On and Off
	  commands, but	not Dim	or Bright, to which the	shutter
	  module is reported to	react in an unpredictable manner.

	  VDATA	- A virtual module which can store a data
	  byte as if it	were a (raw) brightness	level 0-255.
	  Data is written to this virtual module only with the
	   'heyu vdata HU <data>' command - it is unaffected
	  by any other X10 command.

       The  following security transmitter models are included for use with RF
       auxiliary input from a W800RF32A	or RFXCOM receiver.

	  DS10A	- (PDS01) X-10 DS10A Security Door/Window Sensor
	  DS90	- (DS18-1) X-10	DS90 Sec Door/Window Sensor (2 chan)
	  DS18-1  - () ElekHomica DS18 Sec Door/Window Sensor (2 chan)
	  DS18	 - () ElekHomica DS18 Sec Door/Window Sensor (1	chan)
	  MS10A	- (PMS01) X-10	MS10A  Security	 Motion	 Sensor	 (See  section
       "MS10A WARNING" in man page x10aux(5))
	  SH624	- (PSR01) X-10 Security	Remote
	  KR10A	- (PKR02, KR21)	X-10 Security Keyfob Remote.
	  KR18	- (KR18E) Marmitek Security Keyfob Remote.
	  SD10	- () Marmitek SD10 Smoke Detectors
	  SD90	- () Marmitek SD90 Smoke Detectors
	  BMB-SD18 - ()	BMB SD18 Smoke Detector
	  MS90	- (MS18E) Marmitek MS90	Security Motion	Sensor
	  EH-CWSD10 - () ElekHomica EH-CWSD10 Smoke Detector
	  EH-WD210 - ()	ElecHomica EH-WD210 Water Detector
	  GB10	- () Marmitek GB10 Glass Break Detector
	  SVDATA - () Generic X10 Security Remote (all 'vdata')

       Most (but not all) security sensors transmit a 16-bit security ID which
       is detectable with the RFXCOM RF	receiver operating in variable	length
       packet  mode  (the default).  For backward compatibility, the directive
       'SECURID_16  NO'	instructs Heyu to ignore the upper 8-bits.

       Some security sensors, notably the Aux channel of the DS90  Door/Window
       sensor,	have a firmware	bug whereby a parity bit used to check the up-
       per 8 bits of the 16-bit	security ID is incorrect  in  every  other  RF
       repetition,  which  means that half the signals are discarded as	noise.
       The configuration directive 'SECURID_PARITY  NO'	instructs Heyu to dis-
       regard  the parity bit.	It's use is less risky than throwing away half
       the signals, but	if none	of your	sensors	exhibit	this  bug  there's  no
       need to use it.	Configuration directive	'DISPLAY_RAW_RF	 NOISE'	can be
       used to determine whether the bug exists.

       Unlike the larger SH624 security	remote,	the smaller KR10A,  KR18,  and
       KR21  security  keyfob  remotes	have  no physical Away/Home or Max/Min
       switches, and by	default	transmit the swAway and	swMin flags  when  the
       Arm button is pressed.  Appending the parameters	SWHOME and/or SWMAX to
       the alias directive for these keyfob remotes results in the flags being
       decoded respectively as swHome and/or swMax.

       Alternatively, appending	the parameter DUMMY to the above security key-
       fob remote alias	directive results in the signals  transmitted  by  the
       Arm and Disarm button presses being decoded instead as Alert and	Clear,
       thus allowing the remote	to be used for a  user-defined	purpose	 unre-
       lated to	Arm and	Disarm.

       Module  type SEC_IGNORE can be used to ignore signals from X10 Security
       sensors which may not be	under  your  control,  e.g.,  signals  from  a
       nearby  neighbor's  sensor.   An	 unused	Housecode/Unit address must be
       sacrificed.  Specify the	Security IDs for one or	more sensors to	be ig-
       nored.
       Example:
	 ALIAS Neighbor_Sensors	 P6  SEC_IGNORE	 3C  4E	 2A

       The  following entertainment transmitter	model is included for use with
       RF Auxiliary input from a W800RF32A, RFXCOM, or MR26A receiver.

	  UR81A	- (UR61A) X-10 Entertainment Universal Remote.

       The following module types are used to override the settings defined by
       the  TRANSCEIVE	and  RFFORWARD directives for specific units and func-
       tions  within  a	 housecode.   Each  requires  one  of  the  parameters
       TRANSCEIVE,  RFFORWARD,	or  RFIGNORE be	specified following the	module
       name in the ALIAS directive.

	  PALMPAD - Controls RF	On, Off, Dim, Bright.
	  KEYCHAIN - Controls RF On and	Off
	  ONLYON  - Controls RF	On
	  ONLYOFF - Controls RF	Off
	  MS12,	MS13, MS14, MS16 - Controls RF On and Off

       (The MSxx module	types are similar to the KEYCHAIN module type but  are
       defined	as "sensors" and as such will be listed	in the table displayed
       by 'heyu	show sensors'.)

       Example:	If housecode C is set to be transceived, specifying:
	 ALIAS XMMS_Control C1-6  KEYCHAIN  RFFORWARD
       allows using the	On/Off buttons C1-6 on a RF remote to  launch  scripts
       controlling  the	XMMS audio player software on the PC without the delay
       of a powerline signal.  The other unit buttons continue	to  transceive
       powerline signals to lamps and appliances.

	  PLCSENSOR - A	target for a transmitter which sends
	  X10 On and Off signals over the power	line and which has
	  a "heartbeat", i.e., it periodically retransmits its current
	  state.  The Heyu config directives HIDE_UNCHANGED and
	  INACTIVE_TIMEOUT apply to this module	type as	they do	for
	  RF security sensors.

       The following module type decodes RF signals transmitted	from RFXSensor
       modules and received by a W800RF32A/AE or RFXCOM	RF receiver, and  maps
       them to a Housecode|Unit	address.

	  RFXSENSOR - A	decoder	for RFXSensor transmitters
	  and external sensors.	 Two parameters	are required, the
	  base_address of the sensor and a mnemonic for	the type
	  of sensor, e.g., Temperature/Humidity, Temp/Barometric
	  Pressure, etc. The mnemonic will be one of: TH, TB, TV,
	  TP, TT, or T.
       Example:
	  ALIAS	Basement L9 RFXSENSOR 0x20 TH
       The  RF	signals	 sent by the sensor with base_address 0x20 will	be de-
       coded as	RFX  Temperature  and  Relative	 Humidity  functions  received
       (RCVA) at Housecode|Unit	L9.
       See man page x10rfxsensors(5) for full details.

       The  following  module  types decode RF signals transmitted by RFXMeter
       sensors.	 Each requires as a parameter the ID address of	the sensor.
	  RFXPOWER - Electric Watt-Hour	meter.
	  RFXWATER - Water meter.
	  RFXGAS   - Gas meter.
	  RFXPULSE - Pulse meter.
	  RFXCOUNT - General counter.
       Example:
	  ALIAS	MyWaterMeter C9	RFXWATER  0x04

       Module type DIGIMAX decodes RF signals transmitted by the  DigiMax  210
       wireless	 thermostat  and  received by the 433.92 MHz RFXCOM X10	RF re-
       ceiver in variable length packet	mode. Its parameter is the  16-bit  ID
       of the thermostat.

       Module  types  ORE_xxx decode signals transmitted by various Oregon re-
       mote sensors and	received by the	433.92 MHz RFXCOM X10 RF  receiver  in
       variable	 length	 packet	 mode.	See man	page x10oregon(5) for full de-
       scriptions.

       Module type ELS_ELEC1 decodes signals transmitted  by  the  Electrisave
       CM113  Electricity Monitor sensor and received by the 433.92 MHz	RFXCOM
       X10 RF receiver in variable length packet mode. The optional  directive
       "ELS_VOLTAGE <voltage>" specifies a nominal AC voltage to be multiplied
       by the measured current to display an apparent power.  See page X10ore-
       gon(5) for more information.

       Module  type  OWL_ELEC2	decodes	 signals  transmitted by the OWL CM119
       Electricity Monitor sensor and received by the 433.92 MHz RFXCOM	X10 RF
       receiver	 in  variable  length  packet mode. The	directive "OWL_VOLTAGE
       <voltage>" specifies the	nominal	AC voltage to be used to  compute  the
       Power and Energy	values.	 See page X10oregon(5) for more	information.

       SwitchLinc  and	LampLinc  modules can be manually configured to	always
       turn on to some level less than the maximum (32), or always resume  the
       previous	setting.  If you've configured your modules in either of these
       ways, you must inform Heyu of the fact by adding	the module option 'ON-
       LEVEL nn' or 'ONLEVEL RESUME'.

       NOTE: In	order for the Heyu state engine	to properly track the state of
       modules with the	'resume' feature (LM14A	 and  SwitchLinc/LampLinc  op-
       tion),  its memory must be synchronized with the	module's memory.  This
       can be done by sending the module an X10	command	setting	it at a	 known
       level greater than the 'Off' level, or by having	it respond to a	status
       request with a preset/xstatus level greater than	the 'Off' level.

       Examples:
	  ALIAS	 hall_light  B7
	  ALIAS	 patio_lights  B2,4-6
	  ALIAS	 porch_light  D1  WS467
	  ALIAS	 livingroom_lamp H7 SL2LM  ONLEVEL 20

       It is advisable to define single-unit aliases for  all  housecode|units
       in  addition  to	 any multiple-unit aliases which may be	convenient for
       use in Scenes/Usersyns/Macros, and to define  a	Module_type  only  for
       single-unit aliases.
       (Once  a	Module_type is defined,	it applies to that same	housecode|unit
       however used, e.g., in the above	example	Heyu will understand  that  D1
       is  a WS467 dimmer when either 'heyu turn porch_light on' or 'heyu turn
       D1 on' is executed, or if D1 is also included in	a multiple-unit	 alias
       like D1,2-5,7)

       Modules	not defined for	a Housecode|unit in an ALIAS directive are as-
       signed to be the	default	module,	which is a standard X-10 lamp  module.
       This can	be changed with	the DEFAULT_MODULE directive.

       Note:  Versions of Heyu prior to	2 used a different format for aliases:
       No ALIAS	directive was used and the Housecode  letter  and  Units  were
       separated by whitespace,	e.g., simply 'hall_light  B  7'.  For compati-
       bility, Heyu version 2 will still accept	this format, however  its  use
       is  discouraged	and deprecated.	 (Module type cannot be	specified with
       this format.)

DEFAULT_MODULE directive
       Sets the	module attributes of all Housecode|Units which are not defined
       in  an  alias directive.	 If not	otherwise specified by this directive,
       the default module is the standard X-10 plug-in lamp module (StdLM).

START_ENGINE directive
       Many of Heyu's features require the Heyu	state engine  daemon  heyu_en-
       gine  to	 be running.  This directive instructs Heyu how	heyu_engine is
       to be started.  With the	default	value of MANUAL, the  engine  must  be
       started	by entering 'heyu engine' at the command line.	With the value
       AUTO, the engine	will be	started	automatically along with Heyu's	 other
       background processes when 'heyu start' is run.  Example:
	 START_ENGINE  AUTO

LOG_DIR	directive
       Use this	directive to specify the directory in which the	Heyu state en-
       gine daemon should write	its log	file  'heyu.log.<tty>'.	  The  keyword
       'NONE' (which is	the default) instructs Heyu to not write a log file.

       Example:
	  LOG_DIR  /var/log/heyu/

       The  log	file will contain entries like appear in the Heyu monitor, and
       in addition, an entry  whenever	a  script  (excluding  heyuhelper)  is
       launched.   It  will also collect the text output of a launched script,
       if that output isn't redirected to a different file.

       Two or more instances of	Heyu running on	the same computer can share  a
       common log file by appending the	keyword	"COMMON".  If each instance of
       Heyu is started with the	base subdirectory switch (-0 through -9), each
       entry  in  the log file 'heyu.log.common' will display the subdirectory
       number (0 through 9) from whence	the signal originated.

       Example:
	  LOG_DIR  /var/log/heyu  common

       Note that the log file will continue to grow.  Manually delete or  trim
       it  from	 time to time, or configure a Unix utility like	'logrotate' to
       manage it.

DATE_FORMAT directive
       Specifies how a numeric date is displayed.  The syntax for this	direc-
       tive is:
	 DATE_FORMAT  <order>  [<separator>]
       where <order> is
	 YMD  => Year/Month/Day	 (Default)
	 DMY  => Day/Month/Year
	 MDY  => Month/Day/Year
       and where the optional <separator> is '/' (Default), '-', or '.'

       Examples:
	 DATE_FORMAT  YMD  '/' => 2008/01/23  (Heyu default)
	 DATE_FORMAT  YMD  '-' => 2008-01-23  (ISO 8601	standard)
	 DATE_FORMAT  DMY  '-' => 23-01-2008  (many European countries)
	 DATE_FORMAT  DMY  '.' => 23.01.2008  (Germany traditional)
	 DATE_FORMAT  MDY  '/' => 01/23/2008  (USA traditional)

       The  specified  order  of Month and Day also applies to the date	ranges
       specified for Timers in schedule	files to be uploaded to	the CM11A EEP-
       ROM.   The  separator between month and day must	be '/',	'-' or '.' but
       does not	have to	be the same as that specified with  DATE_FORMAT.   The
       separator  between the begin and	end dates may optionally be either '-'
       or ':'.	(Use the latter	for clarity when the Month/Day separator is  a
       '-'.)
       Examples:
	 TIMER	smtwtfs	 01/23-12/31 ...  (with	DATE_FORMAT YMD	or MDY)
	 TIMER	smtwtfs	 23-01:31-12 ...  (with	DATE_FORMAT DMY)

       Dates  where the	month name is spelled out are not affected by this di-
       rective and usually appear like:
	 Wed 23	Jan 2008

LOGDATE_YEAR directive
       Instructs Heyu whether or not the dates reported	for entries in the Log
       file  and  Monitor should include the year.  The	choices	are YES	or NO,
       with the	default	being NO, to omit the year.

TAILPATH directive
       Use this	directive to specify the full pathname of  the	system	'tail'
       command	if  it's  not on the normal PATH accessable to Heyu.  The Heyu
       command 'logtail' will use this pathspec	to call	'tail'.

HEYU_UMASK directive
       Governs the permissions for files created by  Heyu.   The  default  for
       this  directive	is  0000  which	 results  in  files having permissions
       rw_rw_rw_.   The	 value	0002  results  in  files  having   permissions
       rw_rw_r__  ;  the  value	 0022  results	in  files  having  permissions
       rw_r__r__.
       Example:
	 HEYU_UMASK  0002

USERSYN	directive
SCENE directive
       These directives, new to	Heyu version 2,	specify	a  semicolon-separated
       list  of	Heyu commands.	These can then be executed sequentially	by is-
       suing only the usersyn or scene label as	a Heyu command.	 In  addition,
       the label can be	used in	a macro	as if it were a	command.

       In the current release, the ONLY	difference between a SCENE and USERSYN
       is whether they appear in the scene or usersyn list  displayed  by  the
       'heyu show' command.  What applies below	for a SCENE applies equally to
       a USERSYN.

       The format for either a scene or	usersyn	is similar:
	  SCENE	   Label  command1; command2; command3;	...
	  USERSYN  Label  command1; command2; command3;	...

       The commands in a scene can accept either actual	 device	 addresses  or
       aliases.	  (The	alias directive	must appear before any scene directive
       which references	it.)
       Examples:
	  SCENE	 dim_all  dim A1-3  8; dim B2  8; dim c7  8
	  SCENE	 night_lights  off porch_light;	on garage_light; dim hall 8

       Issuing the command 'heyu dim_all' would	result in each of the commands
       defined in that scene to	be executed in turn.

       Scenes  can  also  be  defined with positional parameters which are re-
       placed by actual	parameters when	they are executed.  The	positional pa-
       rameters	 are  designated by a '$' sign followed	by a number 1 to N op-
       tionally	enclosed in curly brackets, e.g., '$2',	 '${7}'.   The	number
       represents  the position	of the parameter in the	argument list supplied
       when the	scene is executed..  A positional parameter  can  be  used  as
       part  or	all of either a	device address or a dim	level, but not as part
       of a scene label	or a Heyu command

       Examples:
	  SCENE	 blinker  on $1; off $1; on $2;	off $2
	  SCENE	 Dim_all  dim A1-3  $1;	dim B2	$1; dim	c7  $1

       These could then	be executed by running:
	  heyu	blinker	 A3  B7
	  heyu	Dim_all	7

       Rules for scenes	(interpret "scene" as meaning either  scene  or	 user-
       syn):

       1.  A  scene label is a case-sensistive ASCII string (maximum length 32
       characters) not beginning with '-' or '_' and not containing blanks  or
       the '+' or '$' characters.

       2.  A  scene  label may not be the same as a Heyu command or any	of its
       synonyms.  A scene label	may not	duplicate a usersyn  label  and	 vice-
       versa.  As of the current implementation, a scene label MAY be the same
       as an alias label, and it MAY be	the same as a macro label,  but	 these
       feature may be restricted in future releases if too much	user confusion
       results.

       3. Only "direct"	and CM17A commands can be used in scenes  -  "adminis-
       trative"	 commands like 'help', 'info', etc., are invalid in scenes, as
       are commands identified as  "legacy"  commands  from  Heyu  version  1.
       (Running	'heyu help' will identify each of these	types of commands.)

       4. A command in a scene may not be another scene.

       5.  Commands  in	 scenes	 are checked for syntax	when the configuration
       file is read, but there is no checking of any  parameter	 containing  a
       positional  parameter until the scene is	actually executed or specified
       in a macro.  The	syntax checking	is performed as	if the scene is	to  be
       executed	at the command line, so	if a scene contains a command which is
       invalid for an uploaded macro, that error won't be  flagged  until  the
       'heyu upload [check]' command is	run.

       6.There	is no restriction on how a positional parameter	is used	within
       a parameter so long as the result is valid when the scene is  executed.
       Use  the	 optional  curly brackets if the result	could otherwise	be am-
       biguous.	 The positional	parameter is first replaced by the actual  pa-
       rameter,	then the result	is checked against the list of aliases.

       7.  The	number	of positional parameters supplied when a scene is exe-
       cuted must agree	exactly	with the number	specified in the scene defini-
       tion.  Thus if '$4' is the highest numbered positional parameter	speci-
       fied in a scene,	then 4 and only	4 parameters must be supplied when the
       scene is	executed.

       8.  If  more than one scene is used in a	macro, or if scenes are	inter-
       mixed with regular macro	commands, they	must  be  separated  by	 semi-
       colons.

       9. Memory for scenes is dynamically allocated so	there is no fixed size
       limit for scenes	intended for execution from the	command	line.  Bear in
       mind  however  the  limited  (1024 byte)	EEPROM space in	the CM11A when
       scenes are expanded in macros, although most common X10 commands	occupy
       only 3 or 4 bytes when converted	to binary.

       10.  The	highest	numbered positional parameter in a scene is by default
       limited to 8. (In most cases anything over that is more likely  an  er-
       ror.)   But  this  limit	 may  be  changed with configuration directive
       MAX_PPARMS.

MAX_PPARMS directive
       Specifies the highest numbered positional parameter allowed in a	scene.
       The number may have any value between 1 and 999.	 The default is	8.

STATUS_TIMEOUT directive
       Specifies  how  long  Heyu  will	wait for a module to reply to a	status
       command before timing out.  The default is 2  seconds.	Some  modules,
       SwitchLinc  dimmers  in	particular,  may require increasing this to 3.
       The allowed limits for this directive are 1-5 seconds.	(Don't	use  a
       value  any  higher  than	the minimum needed for satisfactory status re-
       porting.)  Example:
	   STATUS_TIMEOUT  2

SPF_TIMEOUT directive
       Specifies how long Heyu will wait for a module to reply to  a  "SPecial
       Function"  status command before	timing out.  The default is 3 seconds.
       To date,	there is only one special function in Heyu, the	display	of the
       temperature  as	encoded	 in  a	preset command returned	from a two-way
       thermostat or remote thermometer.  (See below.)

RCS_DECODE directive
RCS_TEMPERATURE	directive
       This is the same	directive - use	either but not	both.	The  name  has
       been  changed since Heyu	now supports decoding other RCS	status reports
       such as fan status on/off in addition to	temperature.
       This directive instructs	the Heyu monitor to  decode  and  display  the
       status  reports	encoded	in a Preset command transmitted	from a two-way
       thermostat or remote thermometer	employing the algorithm	 used  by  the
       RCS  TX15-B  and	 TXB16 thermostats (shown as a table in	the thermostat
       user's guide).
       The Smarthome TempLinc Model 1625 remote	thermometer uses the same  al-
       gorithm for the temperature report, which is:

	  temperature =	-60 + 32*(unit - 11) + (preset_level - 1)

       If  the Heyu State Engine is running, the decoded temperature is	stored
       at the (fictitious) unit	0 address H0, where 'H'	is  the	 housecode  of
       the  thermostat or thermometer.	It can be recovered with the 'heyu rc-
       stemp H'	command.  Provided a valid temperature has  been  stored,  any
       script launched by Heyu can recover the temperature as the value	of en-
       vironment variable X10_H0 or the	environment  variable  alias  for  H0.
       (Since  these  environment variables are	created	only if	valid data has
       been stored, a check for	their existance, e.g., [ "X10_H0" != ""	], may
       be required before using	them in	a script or shell command.)

		 *** WARNING - WARNING - WARNING ***
       The  use	of Heyu	or any other power-line	protocol software to control a
       heater lacking a	built-in failsafe mechanism is not only	unwise,	it  is
       hazardous to life and downright foolhardy.  DON'T DO IT!

       This  directive	may  have  the	values:	OFF for	no decoding; a list if
       housecodes enclosed in square []	brackets for which decoding is	to  be
       performed; or ALL to decode any housecode.  The default is OFF.
       Examples:
	  RCS_DECODE  OFF	 (no decoding)
	  RCS_DECODE  [CFH]	 (decode on housecodes C, F, and H)
	  RCS_DECODE  ALL	 (decode on any	housecode)

       Note:  This directive need not be used in order to query	the thermostat
       with the	'heyu rcs_req ...' or 'heyu temp_req ...' commands -  it  only
       enables the temperature or other	status to be displayed in Heyu's moni-
       tor, regardless of whether or not  the  thermostat's  transmission  was
       initiated by these commands.  (The TempLinc Model 1625 remote thermome-
       ter can be programmed to	transmit a temperature	report	any  time  the
       temperature changes.)

ACK_HAILS directive
       Setting	this directive to YES will instruct the	Heyu state engine dae-
       mon (if running)	to send	a hail_ack with	the default housecode whenever
       it receives a hail signal over the power	line.  The hail_ack is sent as
       if from a launched script.  The choices are YES or NO, with the default
       being NO.
       Example:
	  ACK_HAILS  NO

AUTOFETCH directive
       When  a	state command which returns the	addressed state	of a module is
       executed	at the command line, Heyu by default (AUTOFETCH	YES) instructs
       the  state engine to first update the state file, since Heyu only auto-
       matically updates this file following  an  X10  function.  Setting  the
       value of	the directive to NO disables this action for (only) those spe-
       cific state commands.  Most users will want to accept the default value
       of  YES.	  See  the description of the 'fetchstate' command in man page
       heyu(1) for a more detailed discussion of this issue.

TIMER_LOOPCOUNT	directive
       Specifies the base loopcount for	the fast timing	loops needed  by  some
       CM17A  and  experimental	commands.  To determine	the value for this di-
       rective,	run 'heyu utility calibrate'.

FORCE_ADDR directive
       Heyu doesn't normally send a separate Housecode|Unit address  byte  for
       commands	 like all_lights_on which don't	actually require the unit num-
       ber (the	housecode is included with the function), or for extended com-
       mands  which contain the	unit number within the function	code.  However
       X-10's ActiveHome software always sends this byte, generally using unit
       13.  This directives forces Heyu	to always send an address byte.
       If  always  sending  an address byte cures some problem you are having,
       choose YES. Otherwise take the default of NO.
       Example:
	  FORCE_ADDR  NO

SPOOLFILE_MAX directive
       This directive sets the limit on	the size of the	spoolfile beyond which
       the  Heyu relay daemon will rewind it once it detects a period of inac-
       tivity (currently 5 seconds).  The size set by this  directive  may  be
       between	20  and	 an absolute maximum 1048576 bytes (but	don't use this
       max value).  The	default	limit is 1000000 bytes.	 For changes  in  this
       directive  to  become  effective	 when Heyu is already running, use the
       'heyu restart' command.

       Note that re-synchronization with the Heyu state	engine daemon or moni-
       tor  takes  a couple of seconds,	during which time Heyu will ignore in-
       coming X10 signals or macro executions.	So don't set a low  limit  ex-
       cept for	testing	purposes.

SECTION	directive
       This directive and anything which follows it on the line	is treated the
       same as a comment and totally ignored by	Heyu.  It is provided  to  en-
       able  user-definable  breakpoints  for  use  by	an external program or
       script to reorganize the	Heyu configuration file.

CHECK_RI_LINE directive
       When the	CM11A receives an X10 signal over the power  line  it  asserts
       the  Ring  Indicator (RI) serial	line for a short time prior to sending
       the signal to the computer.  This directive tells Heyu whether  or  not
       to check	this serial line before	attempting to transmit a command so as
       to help avoid collisions	on the powerline.  The default is  YES.	  This
       check is	normally bypassed for serial port hardware which does not sup-
       port the	serial control lines, so setting this directive	to  NO	should
       only  be	required in exceptional	situations.  One such situation	occurs
       with USB-Serial adapters	using an older Prolific	chip under Linux,  re-
       sulting	in  the	message	"RI serial line	may be stuck" after a long de-
       lay.  Note that this check will be ineffective if the CM11A RI line  is
       disabled	by the following directive.

RING_CTRL directive
       Setting	the  value of this directive to	DISABLE	instructs Heyu to dis-
       able the	CM11A Ring Indicator (RI) line of the CM11A, which would  oth-
       erwise  be asserted each	time an	X10 signal is received over the	power-
       line.  In addition, Heyu	commands like  'heyu  ping'  and  'heyu	 wait'
       which normally employ the CM11A Ring_Enable command for their function-
       ality will substitute the CM11A Ring_Disable command.   This  directive
       is  not totally effective because the CM11A asserts the RI line when it
       is powered up, before Heyu has a	chance to disable  it,	e.g.,  in  the
       event of	a momentary interruption in AC power.

       The ONLY	reason for disabling the RI line is that some computers	have a
       "Start on Ring" feature and/or "Awake from Sleep	on Ring" feature which
       cannot  easily  be  disabled  in	 the computer's	BIOS and disabling the
       CM11A RI	line prevents undesired	startup	of  the	 computer.   Otherwise
       the default value of ENABLE for this directive should not be overridden
       since the function to check the RI line before sending  would  then  be
       ineffective.

       For  changes in this directive to become	effective when Heyu is already
       running,	use 'heyu restart' to incorporate the change in	the heyu_relay
       and heyu_aux daemons.

SEND_RETRIES directive
       Heyu  by	default	attempts to send an X10	address	or function command to
       the CM11A up to 3 times,	which is the default for this  directive.   If
       collisions or noise on the power	line result in _occasional_ "Unable to
       send ..." messages, use this directive to bump up the number a  little.
       Note:  This directive will not help if the failure to send a command is
       due to a	communication problem with the serial port.
       Example:
	  SEND_RETRIES 5

POWERFAIL_UPDATE directive
       When AC power resumes after an interruption, the	CM11A  will  poll  the
       computer	with a constant	stream of requests at one-second intervals for
       a time update and will accept no	other command  until  the  request  is
       satisfied.  The Heyu relay daemon by default automatically responds and
       updates the CM11A clock.	 The choices for this directive	are either YES
       or  NO, with the	default	being YES.  Choosing NO	for this directive in-
       structs heyu_relay to respond with a truncated update  which  satisfies
       the  CM11A  but	doesn't	 actually reset	the clock.  If Heyu is already
       running,	use 'heyu restart' for changes in this directive to become ef-
       fective in the heyu_relay daemon.

       This  directive	allows the user	to determine the accuracy of the CM11A
       clock when operating solely on battery power. E.g., run 'heyu setclock'
       to  set	the CM11A clock	to the system clock, unplug the	CM11A from the
       wall socket for several hours or	a day, plug it back in and  run	 'heyu
       readclock' to compare the CM11A and system clocks.

NEWFORMAT flag (obsolete)
       The  word  NEWFORMAT  formerly  caused the output displayed in the Heyu
       monitor to appear in a slightly different format.  In  Heyu  version  2
       the  monitor  output  is	 very  different  and the older	formats	are no
       longer supported.  This directive will be ignored if it appears in  the
       configuration file.

	      ===============================================
       The following Directives	are applicable when scripts are	to be executed
       by Heyu in response to an X10 signal.  (See 'man	x10scripts(2)' for de-
       tails.)
	      ===============================================

SCRIPT_MODE directive
       The options are HEYUHELPER or SCRIPTS, with the default being SCRIPTS.

       If  HEYUHELPER  is  chosen,  a  shell  script named 'heyuhelper'	on the
       user's path is executed every time an X10 function is received by  Heyu
       from the	interface.  The	argument supplied to the script	is of the form
       <housecode|last_unit|function>, where:
	  housecode is the lower case letter a-p associated with the function
	    which resulted in execution	of 'heyuhelper'
	  last_unit is the last	unit code received on that housecode.
	  function will	be one of the following:  On, Off, AllOn, AllOff,
	    Dim, Bright, LightsOn, LightsOff, Preset, Extended,	Hail, HailAck,
	    Status, StatusOn, StatusOff, DataXfer.

       Examples	of heyuhelper arguments:  a1On	b3Off c14Preset

       Note: The AllOn command in Heyu version 1.xx was	 interpreted  to  mean
       LightsOn	 (All  Lights On).  It is not a	native CM11A command.  In Heyu
       version 2, it instead indicates the simple 'On' function	 whenever  all
       units 1-16 are addressed.

       Another difference from Heyu version 1.35 is that the heyuhelper	script
       is not launched when an uploaded	macro is executed.

       The heyuhelper script is	only executed when X10 functions are  received
       from  the  interface - not when addresses or powerfail messages are re-
       ceived or when functions	are sent.

       All other script-oriented directives with the exception of SCRIPT_SHELL
       and  SCRIPT_CTRL	 are  ignored  with  the  HEYUHELPER option.  Choosing
       SCRIPTS allows one to use the full features of Heyu scripting  (includ-
       ing execution of	an existing 'heyuhelper' script).

SCRIPT_CTRL directive
       Globally	enables	or disables launching of scripts by Heyu.  The default
       value of	ENABLE permits scripts to be launched; the value  DISABLE  in-
       hibits  them  from  being launched.  This will hopefully	be useful when
       the configuration file contains many SCRIPT directives and  it  is  de-
       sired to	temporarily disable them without having	to delete them or com-
       ment them all out. All scripts are affected, including  heyuhelper  and
       powerfail or rfflood scripts.  (This directive may be overridden	at the
       command line by the 'heyu script_ctrl enable|disable' command.)

SCRIPT directive
       Specifies the Linux/Unix	command	to be launched and the conditions  un-
       der  which  it will be launched.	 The conditions	for launching the com-
       mand may	also (or additionally) be specified separately in  a  LAUNCHER
       directive.
       The format is as	follows:
	  SCRIPT  [-l  <label>]	<launch	conditions> :: [exec options] <command
       line>

       The script label	is optional as long as the all the  launch  conditions
       are  contained  within  the SCRIPT line.	 It can	be any arbitrary case-
       sensitive name up to 32 characters in length, not beginning with	a  '-'
       character.   If	no  label is specified,	Heyu will create one using the
       line number where it appears in the config  file	 to  make  it  unique,
       e.g., 'Script_21'.
       If  the	launch	conditions  are	 wholly	 or  in	 part specified	with a
       LAUNCHER	directive, a script label is mandatory,	so that	Heyu can match
       up the script with the assocated	launcher.

       Launch  conditions can be quite simple, like 'A1	on', or	quite complex.
       In addition, there are special launch condition for extraordinary situ-
       ations: -powerfail', '-rfflood',	'-timeout'.
       See x10scripts(5) for a full description	of launch conditions.

       Keep in mind that Heyu will normally launch a script only for the first
       set of launch conditions	which are satisfied, i.e., only	one script  is
       launched	per signal or special condition, although this restriction can
       be overridden.  Launch conditions are tested in the order  they	appear
       in the configuration file.

       The  symbol '::'	(two colons) is	always required	(so that Heyu can dis-
       tinguish	when the launch	conditions end and the command line starts).

       Exec options are	zero or	more of	the following:
	  -xtend (or simply -x)	 Create	an environment compatible  with	 Xtend
       scripts.
	     (No other options are compatible with -xtend.)

	  -rawlevel  (or  simply -r)  Use native raw dimlevels instead of per-
       centages
	     for state bitmaps in the Heyu environment.

	  -noenv (or simply -n)	Provide	no additional environment variables
	     beyond those already in the user's	environment.

       The <command line> can be any executable	binary,	shell script, or shell
       command.

       Examples:
	  SCRIPT  D1 on	::  doorbell_actions.sh
	  SCRIPT  -l wake_em_up	 C1 on :: play $HOME/music/reveille.wav
	  SCRIPT   -l PowerFail	-powerfail :: echo "There was a	power failure"
       | mail
	  SCRIPT  -l RF_Flood  -rfflood	:: heyu	on Siren
	  SCRIPT  -l Timeout -timeout timer2 ::	echo "Timeout on Timer	number
       2" | mail

       If a script directive references	an alias in place of a housecode|unit-
       code, the alias directive must have been	defined	earlier	in the config-
       uration file.

LAUNCHER directive
       This  optional directive	can wholly or in part specify the condition or
       conditions under	which the  associated  script  will  be	 executed  (or
       'launched').
       The format is:
	  LAUNCHER  <script  label>  <launch conditions>; <launch conditions>;
       ...
       where:
	  <script label> identifies the	associated script with the same	label.

       See x10scripts(5) for a full description	of what	can appear in  <launch
       conditions>.

       Multiple	 launchers  for	 the  same script may be continued on the same
       line following a	semicolon, or may be configured	as  separate  LAUNCHER
       lines.

       Example:
       If  no launch condition was specified in	the 'wake_em_up' script	above,
       it would	be specified in	a launcher like	this:
	  LAUNCHER  wake_em_up	C1  on

LAUNCHER_SCANMODE directive
       See section "SCAN MODE" in man page x10scripts(5) for details.

SCRIPT_SHELL directive
       Defines the shell used when a script is	executed.  (Provide  the  full
       pathname.)   The	default	is to use the shell defined by the SHELL vari-
       able in the user's environment, or /bin/sh if no	such variable exist.

LAUNCHPATH_PREFIX directive
LAUNCHPATH_APPEND directive
       Prefix and/or append an additional directory or directories to the  ex-
       isting $PATH in the environment provided	for Heyu scripts.  (This works
       only for	shells where the path separator	is a semicolon.)
       Example:
	  LAUNCHPATH_APPEND  /etc/heyu/scripts

LAUNCH_SOURCE directive
       Sets the	default	source or sources of the X10 signal allowed to	launch
       a  script  as part of the <launch conditions>.  One or more of the fol-
       lowing may be specified.	 The default is	RCVI.
       SNDC   Sent from	the Heyu command line.
       SNDM   Sent upon	execution of an	uploaded macro by a Timer.
       SNDT   Sent upon	execution of an	uploaded macro by a Trigger
       SNDP   Sent by Heyu from	a power-fail script.
       RCVI   Received over the	power line via the CM11A interface.
       RCVT   A	Trigger	which initiates	execution of an	uploaded macro.
       SNDA   Sent over	the power line by the heyu_aux daemon.
       RCVA   Virtual data received from the heyu_aux daemon.
       ANYSRC All of the above.
       NOSRC  None of the above	(sources must be specified in the <launch con-
       ditions>).

       Example:
	  LAUNCH_SOURCE	 rcvi  sndc

ISDARK_OFFSET directive
       Defines	the offset in minutes from Dusk	and Dawn to use	for the	script
       environment logical variable 'X10_isDarkTime'.  Its default value of 30
       minutes	means that 'X10_isDarkTime' will be TRUE from 30 minutes after
       Dusk until 30 minutes before Dawn.  This	directive also determines  the
       interval	during which the launch	condition flag 'dark' is TRUE.

ENV_ALIAS_PREFIX directive
       Determines whether the prefix of	ALIAS environmental variables provided
       for scripts is upper or	lower  case,  i.e.,  'X10_'  or	 'x10_'.   The
       choices are LC or UC, with the default being LC for lower case.

       This  directive	enables	compatibility with scripts written for earlier
       releases	of Heyu	(which used the	upper-case prefix), however its	use is
       discouraged - please modify your	scripts	to use the lower-case 'x10_'as
       soon as practicable.
       Note that this prefix applies _only_ to ALIAS environment  variables  -
       all  other  Heyu	environment variables use the upper-case prefix.  E.g,
       if the configuration file defines:
	 ALIAS	porch_light  A6
       then the	environment variables provided will be:
	 x10_porch_light=nnnn
	 X10_A6=nnnn

STATE_FORMAT directive
       If set to the value OLD,	the output of the  state  commands  'onstate',
       'dimstate', 'chgstate', and 'addrstate' revert to the former heyuhelper
       style, e.g., a2Dim.  Taking the default value NEW  displays  output  as
       either  1  (True)  or 0 (False) when a housecode|unit parameter is pro-
       vided, or a unit	bitmap of the state (bit 0 -> unit 1) as a decimal in-
       teger  when  the	 parameter is a	housecode only.	 This directive	is in-
       tended to provide compatibility with existing scripts.

STATE_CTRL directive
       With the	default	value of "SINGLE" for this directive,  the  output  of
       state  commands	'onstate',  'dimstate',	'chgstate', and	'addrstate' is
       boolian 0 or 1 when the address parameter includes the unit, or a  bit-
       map if the address parameter is only a housecode.  Specifying the value
       of this directive as "BITMAP" results in	the output being a bitmap  re-
       gardless	of whether or not the address include a	unit.

	      ===============================================
       The  following  Directives are applicable when a	schedule of Timers and
       Macros is to be uploaded	by Heyu	to the CM11A's EEPROM.
	      ===============================================

SCHEDULE_FILE directive
       Instructs Heyu to use the named file as the user's schedule file	(which
       must  be	in the same directory as the configuration file).  The default
       is x10.sched.
       Example:
	  SCHEDULE_FILE	 vacation.sched

MODE directive
       Heyu can	operate	in one of two modes insofar  as	 uploaded  timers  and
       macros are concerned.  But before getting into these, first a few words
       about the CM11A interface's internal clock:

       The CM11A clock has no notion of	actual dates,  but  is	merely	a  day
       counter	which  starts from 0 and increments daily until	it reaches 365
       (a total	of 366 days), after which it rolls over	to 0.  An  independant
       counter	keeps  track of	the weekday, starting at 0 (Sunday) and	incre-
       menting daily through 6 (Saturday) before rolling  over	to  0.	 Addi-
       tional  counters	 track	hours,	minutes,  and  seconds	with the usual
       rollovers. (The CM11A has no notion of Standard versus Daylight	Time.)
       The  day	 and  weekday  counters	 increment when	the time rolls over to
       0:00:00.

       In either mode, the CM11A clock is maintained by	Heyu on	Standard  Time
       thoughout  the  year.  Timers scheduled by the user in Civil (i.e. wall
       clock) time are automatically divided by	Heyu into separate timers  for
       periods of Standard and Daylight	Time during the	year.  Time management
       is intended to be handled by Heyu transparently to the user.

       In COMPATIBLE mode, the CM11A clock is configured such that Day 0  cor-
       responds	 to  Jan  1st in the current year and the uploaded schedule of
       timers and macros is prepared to	run for	366 days, i.e.,	through	either
       Dec  31st  or  the  following Jan 1st, depending	on whether the current
       year is a leap or common	year.  In order	to maintain the	proper	corre-
       spondence, the user's schedule must be re-uploaded on Jan 1st, at least
       in years	following common years.	(The CM11A will	otherwise  keep	 chug-
       ging away, but events fired off will be a day in	error.)

       In HEYU mode, the CM11A clock is	configured such	that Day 0 corresponds
       not to Jan 1st but to today's date.  The	uploaded schedule can be  con-
       figured	to  run	 for  any  period  between 1 and 366 days via the PRO-
       GRAM_DAYS directive.  (See the description of that directive  for  rea-
       sons  for wanting this.)	 The user's schedule can be re-uploaded	at any
       time prior to expiration	of the PROGRAM_DAYS period and	correspondance
       will  be	 maintained for	the next period	of PROGRAM_DAYS.  Note however
       that if this period is  allowed	to  expire  without  re-uploading  the
       schedule,  the  CM11A will cease	to fire	off any	programmed events (un-
       less of course the period is set	for 366	days).

       The schedule should be programmed for the entire	year regardless	of the
       MODE  or	 PROGRAM_DAYS directives.  Based on those directives, Heyu de-
       termines	what parts of it to use	and what parts	to  ignore.   In  HEYU
       mode, events scheduled for execution on dates earlier than today's date
       wrap around into	next year.
       Examples:

	  MODE	COMPATIBLE
	  MODE	HEYU

		 *** WARNING - WARNING - WARNING ***
       Users running PCs configured for	dual-boot between Linux	and MS-Windows
       should  NOT  operate  Heyu in HEYU mode if they expect to ever manually
       execute X-10's ActiveHome(TM) program  (or  allow  its  "Communications
       Bridge" driver to be launched at	boot time).  Here's why:

       If the CM11A detects that its AC	power has been interrupted, even for a
       very short time,	it will	continually issue commands back	to the PC  re-
       questing	 a  clock  update. ActiveHome and/or its Communications	Bridge
       will _silently_ comply with this	request	(as will  Heyu's  Relay),  but
       ActiveHome  will	 set the CM11A clock to	an incorrect date and time for
       HEYU mode.  (This is easily and automatically corrected by running  the
       'heyu  setclock'	 command,  but	the  PC	 has  to be rebooted back into
       Linux/Unix to do	it.)

PROGRAM_DAYS directive
       When operating Heyu to upload timers and	macros to the CM11A  interface
       in  HEYU	 mode,	this  directive	instructs Heyu to compile the uploaded
       schedule	to run for the number of days specified	(1-366), beginning to-
       day.   This  directive  is  ignored when	Heyu is	operated in COMPATIBLE
       mode.  The default value	is 366 days.  Example:

	  PROGRAM_DAYS	90

       The advantage to	running	for a shorter number of	days  becomes  evident
       when  timers  are programmed for	Dawn- or Dusk-relative times.  Because
       of the limited size (1024 bytes)	of the CM11A EEPROM memory, Heyu  uses
       a stair-step approximation to the daily times of	Dawn and Dusk over the
       PROGRAM_DAYS interval.  The unequal-length step	intervals  are	deter-
       mined  iteratively to minimize the error	while fitting in the available
       EEPROM memory space.

       As a result, even a single Dawn-	or Dusk-relative timer will  generally
       occupy  most  of	the EEPROM space.  However as more timers are added to
       the schedule, the stair-steps are recalculated so everything will  fit,
       although	at the expense of a larger error.

LATITUDE directive
LONGITUDE directive
       These are used to allow Heyu to compute the times of dawn and dusk over
       the year	for your particular location.  There are no defaults.

       The format of the directive line	is the word  LATITUDE  followed	 by  a
       space  and  then	 the  direction, degrees, a colon and the minutes. The
       LONGITUDE directive follows the same format.  Example:
	  LATITUDE    N37:41
	  LONGITUDE   W121:52

       Note: Versions of Heyu earlier than 2 did not use a direction (N/S/E/W)
       symbol  and  assumed the	convention that	positive Latitude is North and
       positive	Longitude is West.  For	compatibility,	Heyu  version  2  will
       make the	same assumptions if the	direction symbol is omitted.

COMBINE_EVENTS directive
       This  directive	instructs  Heyu	whether	or not to combine events which
       have the	same day-of-week code, date range, type	(i.e., Clock, Dawn, or
       Dusk  based), and time-of-day.  Heyu then needs to upload only a	single
       timer executing a concatenated macro, which saves  considerable	EEPROM
       space when Dawn/Dusk relative timers are	programmed.
       The choices are YES or NO, with the default being YES.
       The  downside  to  using	this feature is	that the Heyu-assigned name of
       the concatenated	macro will not be easily recognizable  when  displayed
       in Heyu's monitor.

COMPRESS_MACROS	directive
       This  directive	instructs  Heyu	to merge unit codes for	macro elements
       which have the same command, housecode, and "data"  (e.g.  dim  level),
       and also	eliminate duplicate elements.  It can save a few bytes of EEP-
       ROM space, when macros with similar elements are	concatenated.
       The choices are YES or NO, with the default being NO.

       Example:
	  macro	mac1 0	on A1; on B1; on A2; on	B3
       becomes:
	  macro	mac1 0	on A1,2; on B1,3

       Warning:	If you program a macro like:
	  macro	mac1 0	on A1; off A1; on A1; off A1; on A1; off A1; ...
       and expect to have a lamp on A1 repeatedly blinking on and off,	better
       set this	directive to NO, else the macro	will be	compressed to a	single
       on and off.  (Heyu maintains the	ordering in macros to the extent  pos-
       sible.)

DAWNDUSK_DEF directive
       By  default  Heyu defines Dawn and Dusk to be Sunrise and Sunset.  This
       directive allows	globally defining them	instead	 as  the  morning  and
       evening times of	several	standard twilights, or as times	calculated for
       a custom	position of the	Sun centre below the horizon, specified	in an-
       gle minutes, as follows:
       RISESET (or simply 'R') - Sunrise and Sunset (default)
       CIVIL (or simply	'C') - Civil Twilight
       NAUTICAL	(or simply 'N')	- Nautical Twilight
       ASTRONOMICAL (or	simply 'A') - Astronomical Twilight
       OFFSET  [-]NN (or simply	'O [-]NN') - Sun position in angle minutes be-
       low the horizon (actually above the horizon if -NN)

       Example:
	 DAWNDUSK_DEF  CIVIL
	 DAWNDUSK_DEF  N
	 DAWNDUSK_DEF  OFFSET 0

DAWN_OPTION directive
DUSK_OPTION directive
       These directives	instruct Heyu how to assign the	time for Dawn or  Dusk
       in each timer subinterval. The options for this directive are:
       FIRST	- Use the Dawn/Dusk time for the first day in the subinterval.
       EARLIEST	 -  Use	the earliest of	the times for any day in the subinter-
       val.
       LATEST	- Use the latest of the	times for any day in the subinterval.
       AVERAGE	- Use the arithmetic average of	the times in the subinterval.
       MEDIAN	- Use a	time halfway between the earliest and latest times.

       The default is FIRST, which is the most convenient for comparing	Heyu's
       computations  with Dawn/Dusk times published in newspapers or by	the US
       Naval Observatory.  (Remember that  Heyu's  times  are  Standard	 Time,
       while newspapers	generally publish Civil	[wall clock] times.)

MIN_DAWN directive
MAX_DAWN directive
MIN_DUSK directive
MAX_DUSK directive
       These  directives  allow	 bounds	 to be placed on the times of Dawn and
       Dusk computed by	Heyu. For example, setting the value for  MIN_DAWN  to
       06:30 will instruct Heyu	to execute a timed event scheduled for dawn at
       06:30 instead, whenever the computed time  for  dawn  is	 earlier  than
       06:30.	These directives may be	useful for users in extreme latitudes,
       when for	example	a lamp is scheduled to turn on at dusk and turn	off at
       9:30  PM.   But	if during the summer months dusk actually occurs after
       that hour, then the on/off cycle	of the	lamp  would  normally  be  re-
       versed, turning on at that late dusk and	remaining on until 9:30	PM the
       following day.

       The value for these directives are  specified  as  hh:mm	 Civil	(i.e.,
       wall-clock)  time.  The directives may be disabled with the word	OFF in
       place of	a time.	 The default is	OFF.

       Heyu version 2 now has timer options  for  conditional  compilation  of
       events  depending  on  the values of Dawn and Dusk, so these directives
       may no longer be	useful.

       (Note: Due to Heyu's optimizations, the order in	which events scheduled
       for  the	 same  time  are  actually executed is not necessarily that in
       which they appear in the	user's schedule	file.  Allow at	 least	a  one
       minute  time  difference	when order is important.  The actual order can
       be determined from the list of timers in	the OUTPUT TIMERS  section  of
       the  report.txt	file  written  when  a	schedule is uploaded or	upload
       checked.)

DAWN_SUBSTITUTE	directive
DUSK_SUBSTITUTE	directive
       These directives	are obsolete and will be ignored.

REPORT_PATH directive
       Reports 'report.txt' and/or 'cronreport.txt' created when  the  command
       'heyu  upload  [check|croncheck]'  is run are by	default	written	in the
       Heyu base directory, i.e., the directory	where the  configuration  file
       is  stored.   This  directive  instructs	Heyu where the user would like
       them written instead.  The full pathspec	is  required  (127  characters
       maximum).
       Example:
	  REPORT_PATH  ./

WRITE_CHECK_FILES directive
       When  a	schedule  is  actually	uploaded  to  the CM11A's EEPROM, Heyu
       records critical	information in the files 'x10record',  'x10macroxref',
       and  'x10image'.	  For debugging	or informational purposes, this	direc-
       tive instructs Heyu to write these files	with a .check  extension  when
       'heyu upload check' is run.

       In  addition,  this  directive  instructs  Heyu to write	'x10image.hex'
       which is	a human-readable hex dump of the EEPROM	memory image.

       The choices here	are YES	or NO.	The default is NO.

REPL_DELAYED_MACROS directive
       This directive instructs	Heyu to	replace	events having  delayed	macros
       with  new  events and new undelayed macros when possible.  (The purpose
       is to avoid pending delayed macros, which are purged when a new	sched-
       ule  is	uploaded.)   The choices are YES or NO,	with the default being
       YES.

ASIF_DATE directive
       Used for	test purposes, this directive instructs	Heyu to	substitute the
       argument	 date  for  today's  date  when	processing the user's schedule
       file.
       The date	format is yyyymmdd.
       Example:
	  ASIF_DATE  20020621

ASIF_TIME directive
       Used mainly for test purposes, this directive instructs Heyu to use the
       argument	 time  of  day	instead	of the system time when	processing the
       user's schedule file. Its format	is hh:mm (Civil	Time).	The default is
       to use the current system time.
       Example (simulates operation at Noon):
	  ASIF_TIME    12:00

FEB_KLUGE directive
       Heyu  ver  2  always  interprets	02/30 as the last day of February when
       used as a start or stop date.  This directive instructs	Heyu  to  also
       interpret  02/28	 and  02/29  as	the last day of	February.  The options
       here are	YES or NO, with	YES being the default.	 (If  you  choose  NO,
       programming  02/28 or 02/29 in the wrong	year could result in a skipped
       day, an event occurring twice, or possibly an error, depending on  cir-
       cumstances.)

RESOLVE_OVERLAP	directive
       When uploaded timers specify Dawn/Dusk periods with different begin and
       end points, Heyu	resolves the situation	such  that  the	 approximation
       time used for Dawn and/or Dusk is the same for every timer on any given
       day.  There are two methods for doing this and in most cases the	 newer
       method  appears to give better results in term of maximum error on Dawn
       or Dusk.	 This directive	allows returning to  the  previous  method  if
       more  satisfactory.   The choices here are OLD or NEW, with the default
       being NEW.
       If the timers in	your schedule involve only clock times	or  don't  in-
       volve  both  Dawn and Dusk-relative times, either choice	will yield the
       same result.
       (A future release of Heyu will make  this  determination	 automatically
       and obsolete this directive.)

FIX_STOPSTART_ERROR directive
       With  parameter	"YES"  is a work around	for the	CM11A EEPROM bug "Stop
       Time = Start Time" which	is  occasionally  encountered  when  uploading
       specific	schedules.  It should be used (generally as a "config" line in
       the schedule file) only when needed as it results in less efficient use
       of the EEPROM memory space.

	      ===============================================
       The following directives	are applicable to CM17A
	      ===============================================

RF_POST_DELAY directive
       This directive specifies	the delay in milliseconds following each stan-
       dard RF command to a CM17A "Firecracker"	to allow time for  the	trans-
       ceiver  to respond with its power line signal.  The default is 850 mil-
       liseconds.
       Example:

	 RF_POST_DELAY	850

RF_FARB_DELAY directive
RF_FARW_DELAY directive
       Specifies the delay in milliseconds following respectively a 'farb'  or
       'farw'  RF  command to a	CM17A.	The default is 850 milliseconds.  This
       delay is	specified separately from that for the standard	RF commands so
       that these commands can be used to control devices that don't involve a
       transceiver and power line signals.

RF_BURSTS directive
       Specifies how many RF bursts (1-5) are to be transmitted	with each  ac-
       tuation	of  the	 CM17A	commands  fon, foff, fdim, fbright, flightson,
       flightsoff, falloff, farb, and farw.   Some  transceivers  will	repeat
       some  power line	signals	more than once when they receive the default 5
       RF bursts.  This	is ordinarily not a problem except possibly  when  the
       particular power	line signal is used to launch a	script,	in which event
       this directive can be useful.

       This directive has the syntax:
       'RF_BURSTS <command> <bursts> [<command>	<bursts> [...]]	', e.g.,
	 RF_BURSTS falloff 3 flightson 3 fdim 4

       Note: Previous releases of Heyu required	that each command  be  entered
       on  a  separate	RF_BURSTS  line	and multiple RF_BURSTS directive lines
       were allowed.

       The default for all CM17A commands is 5	bursts.	  For  commands	 fdim,
       fbright,	 and farb where	the total number of bursts is specified	on the
       command line, the CM17A will be actuated	multiple times,	with the maxi-
       mum number of bursts each time specified	by this	directive.

       The RF_BURSTS directive is not used for the "fast" ffdim, ffbright, and
       ffarb commands.

TIMER_LOOPCOUNT	directive
       Specifies the base countdown for	fast timing loops.  These are  usually
       needed  to  actuate  the	 CM17A	for  the  "fast"  'ffdim', 'ffbright',
       'ffarb',	and 'ffarw' commands.  The value to use	for this directive  is
       obtained	by running 'heyu utility calibrate'.

       For  the	 CM17A fast commands, the default value	of zero	instructs Heyu
       to use a	kernel timer instead of	a timing loop, but the	resolution  of
       the  kernel  timers  for	most Unix/Linux	kernels	is not fine enough for
       this purpose.

CM17A_BIT_DELAY	directive
       Specifies the programmed	delay in _microseconds_	between	bits  sent  to
       the  CM17A  device.   X10's  RF protocol	specifies a minimum of 500 mi-
       croseconds and the default here is  500	microseconds.	For  Linux  at
       least the minimum resolution of the kernel timer	is usually much	longer
       than this, typically 10 milliseconds, so	changing  the  value  probably
       won't  accomplish  anything except for the "fast" CM17A commands	when a
       timing loop is used.

DISPLAY_RF_XMIT	directive
       Determines whether an entry will	appear in the  monitor	and  log  file
       when  a	CM17A  command is executed.  The choices are NO	or YES or VER-
       BOSE, with the default being YES.  Using	VERBOSE	is like	 YES  but  the
       triplet [XX YY B] is appended to	each displayed entry.  The XX, YY, and
       B are respectively the two hex bytes and	decimal	bursts which could  be
       sent with the equivalent	'farb XX YY B' command.

       One  quirk is that with multiple	CM17A commands the RF entries will not
       necessarily be properly interleaved with	the  entries  for  transceived
       power  line signals resulting from the RF command.  This	is because the
       CM11A doesn't instantly report reception	of the power  line  signals  -
       there  can  be  a delay of a second or more.  The only workaround is to
       increase	the RF_POST_DELAY to 2000 or 3000 milliseconds,	 which	really
       slows down the RF commands.

RF_NOSWITCH directive
       This  directive	determines whether actuation of	the built-in appliance
       module switch on	an X-10	TM751 or RR501 is to be	 suppressed  when  the
       transceiver  receives  the  fon,	foff, or falloff RF signal on the unit
       code for	the switch.  Setting the parameter of this  directive  to  YES
       will  suppress actuation	of the switch with its accompanying loud audi-
       ble click.  The default is NO.

	      ===============================================
       The following directives	provide	controls for RF	input to Heyu from the
       auxiliary  port	daemon	heyu_aux.  They're more	fully explained	in man
       page x10aux(5).

	      ===============================================

TTY_AUX	directive
       Specify the auxiliary serial port or network address  and  RF  receiver
       device.

	 TTY_AUX  <serial_port or network_address:port>	 <receiver device>
       where <receiver device> is W800RF32A, MR26A, or RFXCOM.	Examples:
	 TTY_AUX  /dev/ttyS1  W800RF32A
	 TTY_AUX  10.10.10.10:10000  RFXCOM

       There is	no default for this directive.

SUPPRESS_RFXJAM	directive
       Older firmware versions of the RFXCOM receiver sent a special "jamming"
       signal when they	detected RF jamming, but the system was	prone to  many
       false  positives	 and  the  feature was removed.	 This directive	allows
       suppressing the jamming signals from older RFXCOM versions by  treating
       them as RF Noise.
       The  options  for  this directive are YES or NO,	with the default being
       NO.

ALIAS directive
       For RF signals received by the W800RF32A	from security remotes and sen-
       sors, this ALIAS	format maps the	device to a housecode|unit address.
	 ALIAS	<label>	<housecode|unit> <device model>	 <ID> [<ID> [<ID>...]]
       where  <ID> represents the security ID of a device expressed as a hexa-
       decimal number, either with or without the "0x" prefix.	Up to 16 secu-
       rity  IDs can be	associated with	a single housecode|unit	address	in the
       case of multiple	security remotes of the	same model.  (Each sensor  de-
       vice should be mapped to	its own	address.)  Examples:
	 ALIAS kitchen_door F11	DS10A 0x3c
	 ALIAS keychain_remote G8 KR10A	2a b4 c7

       The  ID	for entertainment remotes like the UR81A is fixed and included
       in the model, so	isn't specified	with the ALIAS directive.

TRANSCEIVE directive
RFFORWARD directive
       Determine which housecodes which	are to be transceived  to  power  line
       code (source SNDA) by the heyu_aux daemon and which housecodes are for-
       warded directly (source RCVA) to	the heyu_engine	daemon	for  launching
       scripts	or  whatever.  These applies only to signals from Standard X10
       remotes,	not security or	entertainment remotes.
	 TRANSCEIVE  <list>
	 RFFORWARD  <list>
       where <list> may	be the keywords	ALL or NONE, or	may  be	 a  string  of
       housecode  enclosed  in	square [] brackets.  Additionally, the keyword
       ALLEXCEPT followed by the housecode string in square  brackets  may  be
       used. Example:
	 TRANSCEIVE  [BFH]
	 RFFORWARD [DE]
       which will transceive standard X10 RF signals on	housecode B, F,	and H,
       and forward X10 RF signals on housecodes	D and E.  RF  signals  on  all
       other housecodes	will be	ignored.  Another example:
	 TRANSCEIVE [BFH]
	 RFFORWARD ALLEXCEPT [BFH]

       The  default for	the TRANSCEIVE directive is ALL, and for the RFFORWARD
       directive is NONE, meaning that	signals	 on  all  housecodes  will  be
       transceived.   The  same	 housecode cannot be both transceived and for-
       warded.

       Certain special module types have options to  override  the  TRANSCEIVE
       and  RFFORWARD  lists for specific units	and functions within a housec-
       ode.

TRANS_DIMLEVEL directive
       This directive specifies	the dim	level (1-22) for each RF Dim or	Bright
       signal  transceived (or forwarded) by heyu_aux.	The default level is 2
       which results in	a brightness level change of about 6 percent in	 stan-
       dard X-10 Lamp Modules.
       Example:
	 TRANS_DIMLEVEL	 2

AUX_REPCOUNTS directive
       This  directive	instructs heyu_aux how to handle multiple bursts in an
       uninterrupted sequence by providing 3 numbers:
	 AUX_REPCOUNTS	<MIN> <REPEAT> <MAX>
       See man page x10aux(5) for details.  Most users won't  need  to	change
       the defaults (1 8 200) for this directive.

DISPLAY_RAW_RF directive
       This directive instructs	Heyu whether or	not to display the raw RF data
       bytes from the receiver device.	The choices are	the default "NONE"  to
       not display any raw data, "NOISE" to display data which heyu_aux	judges
       to be RF	noise, or "ALL"	to display both	noise and normal raw RF	 data.
       Only change from	the default for	testing	or debugging.

SECURID_16 directive
       This  directive	determines whether Heyu	will use the full 16-bit ID of
       security	sensors	when received by a RFXCOM receiver in variable	length
       packet  mode.  It is provided primarily for temporary backward compati-
       bility in case the user has a large number of sensors  configured  with
       8-bit  IDs,  until they can be reconfigured.  The parameters are	YES or
       NO, with	the default being YES.	The ID	of  a  security	 device	 which
       transmits  only an 8-bit	ID is taken to be the lower byte of the	16-bit
       ID.

SECURID_PARITY directive
       Security	sensor transmissions include  a	 parity	 check	on  the	 upper
       8-bits  of  a  16-bit ID.  Some sensors,	notably	the Aux	channel	of the
       DS90 Door/Window	sensor,	incorrectly report the parity on half  of  the
       RF  repetitions.	  This	directive with parameter YES (which is the de-
       fault) instructs	Heyu to	check the parity.  The parameter NO  instructs
       Heyu to ignore the parity.  Use NO only if you have a sensor exhibiting
       this bug.

HIDE_UNCHANGED directive
       This directive applies only to transmitters identified by their	module
       type  as	 having	a "heartbeat", i.e., sensors which periodically	repeat
       their current state as an "I am alive" indication.  The choices are YES
       or  NO, with the	default	being NO.  With	YES, the sensor	signal is dis-
       played in the monitor and log file only when there's a change from  the
       previous	state of the sensor or if the signal launches a	script.

HIDE_UNCHANGED_INACTIVE	directive
       As above, but for the "func Inactive" pseudo_signal.

ORE_LOWBATTERY directive
       Defines	for Oregon sensors which transmit a battery level the percent-
       age at or below which Heyu will raise the low-battery  ("LoBat")	 flag.
       The default is 20%.  Note that many Oregon sensor models	transmit a low
       battery indicator rather	than a battery level,  and  for	 these	models
       this directive has no effect.
       Example:
	 ORE_LOWBATTERY	10%

ORE_CHGBITS_T directive
ORE_CHGBITS_RH directive
ORE_CHGBITS_BP directive
       Define  for Oregon Temperature, Relative	Humidity, and Barometric Pres-
       sure sensors the	difference between succesive data values required  for
       the  data  value	 to  be	identified as "changed".  The parameter	is the
       number of least counts for the data in question.	 The default for  each
       is 1.  See man page x10oregon(5)	for details.

ELS_CHGBITS_CURR directive
       Define  for  the	 Electrisave  sensor the difference between successive
       current values required for the data to be identified as	changed.   The
       parameter  is  the number of least counts for the data.	The default is
       1, which	corresponds to 0.1 Ampere.  See	man page x10oregon(5) for  de-
       tails.

OWL_CHGBITS_POWER directive
OWL_CHGBITS_ENERGY directive
       Define for the Owl CM119	sensor the difference between successive Power
       and Energy values for the data to be identified as changed.  The	param-
       eter  is	 the number of least counts for	the data in question.  The de-
       fault for each is 1, corresponding to  0.001kW  and  0.0001kWh  respec-
       tively.	See man	page x10oregon(5) for details.

OWL_DISPLAY_COUNT directive
       Determines whether the raw data is displayed in the monitor/logfile for
       Owl CM119 sensors.  The parameter choises are YES or NO,	with  the  de-
       fault being NO.

ORE_DATA_ENTRY
       Defines	whether	 data  is entered in Oregon native or scaled units for
       Oregon sensor emulation.	 The parameter choices are NATIVE  or  SCALED,
       with  the  default being	NATIVE.	 See section "OREGON SENSOR EMULATION"
       in man page x10oregon(5)	for details.

ORE_DISPLAY_CHAN directive
       Determines whether the channel number of	an Oregon sensor is  displayed
       in the logfile, monitor,	and 'heyu show oregon' table.  Setting the pa-
       rameter of this directive to NO suppresses display of the channel  num-
       ber, while with the default YES the channel number is displayed.

ORE_DISPLAY_FCAST
       Determines  whether  the	"weather forecast" transmitted by Oregon Baro-
       metric Pressure sensors (currently module types ORE_THB1	and  ORE_THB2)
       is  displayed  in the logfile, monitor, and in 'heyu show oregon'.  The
       choices are YES or NO, with the default being NO.  The displayed	 fore-
       cast  will  be  "Sunny",	"PtCloudy", "Cloudy" or	"Rain".	 The algorithm
       employed	in the sensor firmware is currenly unknown but is  assumed  to
       be related only to the value of and changes in BP.  (Indoor temperature
       and humidity data from a	sensor rated only for indoor  use  can	hardly
       have a bearing on a weather forecast.)

ORE_DISPLAY_COUNT directive
       Determines whether the raw data is displayed in the monitor/logfile for
       Oregon Wind and Rain sensors.  The parameter choises  are  YES  or  NO,
       with the	default	being NO.

RFXCOM_DISABLE directive
       The  RFXCOM  RF receiver	hardware may be	configured to suppress signals
       from specific sensor types to improve noise immunity and/or  to	ignore
       foreign	signals	from nearby sensors.  Its use supercedes the directive
       RFXCOM_ENABLE, which is now obsolete since newer	RFXCOM	firmware  sup-
       ports a wider variety of	signal types.
       The syntax is:
	 RFXCOM_DISABLE	 <type>	[<type>	[<type>	...]]]

       The signal types	which may be disabled are currently:
	 OREGON
	 ARCTECH
	 ATIWONDER
	 KOPPLA
	 X10	  (Standard and	Security X10)
	 HE_UK	  (HomeEasy - UK and KAKU protocols)
	 HE_EU	  (HomeEasy - EU protocol)
	 VISONIC  (Receivable only by RFXCOM VISONIC receivers.)

       All but HE_UK and HE_EU may be abbreviated to three characters.

       Examples:
	 RFXCOM_DISABLE	 OREGON
	 RFXCOM_DISABLE	 ORE  ARC  ATI

RFXCOM_ENABLE directive
       This is now obsolete.  See RFXCOM_DISABLE above.

	      ===============================================
       The  following  directives  provide controls for	Heyu's security	system
       features.
	      ===============================================

ARM_MAX_DELAY directive
       When the	'heyu arm max ...' command is entered at the command  line  or
       received	 from  the  RF	auxiliary device, Heyu's security flag is ini-
       tially set to "armpending".  At the end of the delay (in	seconds) spec-
       ified by	this directive,	the security flag is changed from "armpending"
       to "armed".  The	following example specifies the	delay to  be  30  sec-
       onds:
	 ARM_MAX_DELAY 30

       The default for this directive is 0 (zero), which sets the "armed" flag
       immediately regardless of the "max" or "min" parameter.

ARM_REMOTE directive
       This directive controls the behavior of Heyu when an  'arm'  signal  is
       received	from an	RF Security remote (source RCVA).  The allowed parame-
       ters are	AUTO or	MANUAL,	with the default being AUTO.  If set  to  MAN-
       UAL,  the  signal does not automatically	set the	global security	flags,
       thus allowing the signal	to be used to launch a script to customize the
       arming  process,	 e.g.,	to  first check	that all doors and windows are
       closed and take an alternate action if they are	not.   This  directive
       has  no	effect for 'arm' commands originating from the command line or
       other sources.

INACTIVE_TIMEOUT directive
       Most security sensors transmit a	signal with their current state	(known
       as  a  "heatbeat") every	60-90 minutes to let the host system know they
       are operational.
       RFXSensors do the same thing every  40  or  80  minutes,	 depending  on
       whether hardware	configured for fast or slow sampling.
       Oregon sensors transmit at intervals of 11 to 120 seconds, depending on
       model.

       Heyu records the	times the signals are received.	  The  commands	 'heyu
       sensorfault'  and  'heyu	 show sensors' compare the elapsed times since
       the last	received signals with the value	specified with this  directive
       to judge	whether	a sensor has become inactive.

       The value for this directive may	be specifies in	seconds	or in hh:mm:ss
       format.	The default is 4:00:00 or 4 hours.  Example:
	 INACTIVE_TIMEOUT  4:00:00

       This directive (or its default) can be overridden for a specific	sensor
       having  a heartbeat by appending	the parameters "IATO  hh:mm:ss"	to the
       ALIAS directive which maps that sensor to a Hu addresss.

INACTIVE_HANDLING directive.
       The parameter choice is NEW or OLD, with	the default being NEW.	Choos-
       ing  OLD	 reverts to the	previous way Heyu handled the situation	when a
       sensor having a heartbeat failed	to send	a signal within	 the  interval
       defined	by the INACTIVE_TIMEOUT	directive.  See	man page x10scripts(5)
       for details.

ARM_LOGIC directive
       The value of this directive may	be  specified  as  STRICT,  LOOSE,  or
       MEDIUM.	The default is MEDIUM.

       When  specified	as  STRICT,  the  state	 of  the security flags	may be
       changed from "disarmed" to "armed" or "armpending" and vice-versa,  but
       no  changes  between  "armed"  and  "armpending"	 or between "home" and
       "away" are allowed.  I.e., the system must be in	the  "disarmed"	 state
       before any 'heyu	arm ...' command can take effect.

       When  specified	as  LOOSE  all changes are allowed.  A ramification is
       that the	'arm max ...' command  when  the  system  is  already  in  the
       "armed"	state will effectively disarm the system - put it in the "arm-
       pending"	state -	for the	duration specified by the ARM_MAX_DELAY	direc-
       tive for	as long	as this	command	continues to be	executed.

       When specified as MEDIUM, all changes are allowed except	the transition
       from "armed" to "armpending".

       Example:
	 ARM_LOGIC  MEDIUM

	      ===============================================
       The following experimental directives are  otherwise  undocumented  and
       may  or may not be useful for testing, hacking, or troubleshooting pur-
       poses.
	      ===============================================

CM11A_QUERY_DELAY directive
       On some systems a short delay appears to	be required between a  message
       from  the  CM11A	that it	has incoming powerline data and	Heyu's polling
       for that	data.  The parameter for this directive	 specifies  the	 delay
       time  in	 milliseconds.	The default is 0, indicating no	delay.	Use of
       this directive may resolve the problem when Heyu	reports:  "The	inter-
       face  didn't answer a getinfo response."	when attempting	to receive in-
       coming powerline	data.
       Example:
	 CM11A_QUERY_DELAY  10	 # 10 millisecond delay

LOCK_TIMEOUT directive
       Before a	Heyu process can write to the spool file it must first acquire
       the  writefile  lock.  This directive specifies how long	a Heyu process
       will spend trying to acquire the	lock before timing out	and  quitting.
       Having a	number of Heyu processes active	at the same time and processes
       which hog the spool file, e.g., when sending commands to	the CM11,  may
       require	increasing this	time.  The parameter for this directive	is the
       time in seconds to spend, with the default being	10 seconds.
       Example:
	  LOCK_TIMEOUT	20

DISPLAY_SENSOR_INTV directive
       Setting the parameter of	this directive to YES instructs	Heyu to	append
       to monitor/logfile entries for an Oregon	or Security sensor the elapsed
       time interval in	hh:mm:ss since the  previous  transmission  from  that
       sensor.

LOGDATE_UNIX directive
       This  directive can be used to replace the normal date/time string dis-
       played in the logfile and monitor with Unix time,  i.e.,	 seconds  from
       the 1 Jan 1970 epoch, to	millisecond precision.	The parameter for this
       directive is YES	or NO, with the	default	being NO.

ORE_ID_16 directive.
       Setting the parameter of	this directive to YES expands the ID  code  of
       an  Oregon  sensor to 16-bit by using the channel code of the sensor as
       the upper byte and the normal sensor ID as the lower byte.  The default
       is NO, to use only the normal sensor ID.

ENGINE_POLL directive
       This  directive	sets  the delay	in the polling loop of the Heyu	Engine
       and Heyu	Monitor	daemons. Too low a value results in somewhat excessive
       CPU  usage when idle.  The value	is expressed in	microseconds, with the
       default being 10000 (= 10 milliseconds).	 The valid  range  is  100  to
       1000000 microseconds (1 second).
       Example:
	  ENGINE_POLL 10000

RESTRICT_DIMS directive
       The values for dim and bright levels for	both Direct and	Macro commands
       is specified in the X10 protocol	as  ranging  from  1-22,  however  the
       field  in  the  binary command can accept a number between 0-31.	 It is
       unknown at this time whether additional dims/brights beyond 210 are ac-
       tually sent by the CM11A, however the time for execution	of the command
       is observed to increase approximately  proportionately.	 Setting  this
       directive to NO allows values between 0 and 31 to be programmed without
       generating an error message, while taking the default of	YES  restricts
       the  range to 1-22.  In any event, a CM11A receiving Dim	or Bright sig-
       nals over the AC	power line never reports  an  expanded	value  greater
       than  210, which	is actually reached when the programmed	level is 19 or
       greater.	 (Entering a value of 0	for dim/bright level for my CM11As ap-
       pears to	send the same number of	dims/brights as	level 2, but who knows
       what yours will do.)

POWERFAIL_UPDATE directive
       When AC power resumes after an interruption, the	CM11A  will  poll  the
       computer	with a constant	stream of requests at one-second intervals for
       a time update and will accept no	other command  until  the  request  is
       satisfied.   The	 Heyu  relay by	default	automatically responds and up-
       dates the CM11A clock.  The choices for this directive are  either  YES
       or  NO, with the	default	being YES.  Choosing NO	for this directive in-
       structs the relay to respond with a truncated  update  which  satisfies
       the  CM11A  but doesn't actually	reset the clock.  Note:	If Heyu	is al-
       ready running, use 'heyu	restart' for changes in	this directive to  be-
       come effective in the heyu_relay	daemon.

       This  directive	allows the user	to determine the accuracy of the CM11A
       clock when operating solely on battery power. E.g., run 'heyu setclock'
       to  set	the CM11A clock	to the system clock, unplug the	CM11A from the
       wall socket for several hours or	a day, plug it back in and  run	 'heyu
       readclock' to compare the CM11A and system clocks.

AUTO_WAIT directive
       This directive instructs	Heyu to	ping the CM11A before sending each X10
       command.	 It has	been reported that the USB port	on some	non-PC systems
       running	Linux  (toasters, maybe?) seem to need this nudge to wake them
       up.  This directive takes a parameter 0 through	300  representing  the
       maximum	number of pings	(at one	second intervals) to try before	a ping
       response	is received from the CM11A.  The default  is  0,  meaning  the
       CM11A is	not pinged.

ENVIRONMENT
       X10CONFIG - Points to a fully qualified file name of your configuration
       file, if	located	elsewhere than in one of the standard places.
       HEYUSUB - Optionally specifies an additional subdirectory  level	 under
       the standard places where the configuration file	will be	found, i.e.,
	  $HOME/.heyu/$HEYUSUB/
	  /etc/heyu/$HEYUSUB/

AUTHORS
       Re-written   to	 use   the   CM11A  interface  by  Daniel  B.  Suthers
       (dbs@tanj.com).

       Originally written (Known as X10) by Larry Campbell (maynard!campbell).
       System  V port, ID file,	improved display formats, and other cleanup by
       John Chmielewski	(rogue!jlc).  Module aliasing, sunset and sunrise  ad-
       ditions by Paul Fox (pgf@foxharp.boston.ma.us).	Additional functional-
       ity for uploaded	timers and macros and for scripts by Charles W.	Sulli-
       van (cwsulliv01@heyu.org)

SEE ALSO
       http://www.heyu.org
       date(1),	 heyu(1), x10sched(5), x10scripts(5), x10cm17a(5), x10aux(5)

				     local			  X10CONFIG(5)

NAME | DESCRIPTION | TTY directive | TTY dummy directive | HOUSECODE directive | ALIAS directive | DEFAULT_MODULE directive | START_ENGINE directive | LOG_DIR directive | DATE_FORMAT directive | LOGDATE_YEAR directive | TAILPATH directive | HEYU_UMASK directive | USERSYN directive | SCENE directive | MAX_PPARMS directive | STATUS_TIMEOUT directive | SPF_TIMEOUT directive | RCS_DECODE directive | RCS_TEMPERATURE directive | ACK_HAILS directive | AUTOFETCH directive | TIMER_LOOPCOUNT directive | FORCE_ADDR directive | SPOOLFILE_MAX directive | SECTION directive | CHECK_RI_LINE directive | RING_CTRL directive | SEND_RETRIES directive | POWERFAIL_UPDATE directive | NEWFORMAT flag (obsolete) | SCRIPT_MODE directive | SCRIPT_CTRL directive | SCRIPT directive | LAUNCHER directive | LAUNCHER_SCANMODE directive | SCRIPT_SHELL directive | LAUNCHPATH_PREFIX directive | LAUNCHPATH_APPEND directive | LAUNCH_SOURCE directive | ISDARK_OFFSET directive | ENV_ALIAS_PREFIX directive | STATE_FORMAT directive | STATE_CTRL directive | SCHEDULE_FILE directive | MODE directive | PROGRAM_DAYS directive | LATITUDE directive | LONGITUDE directive | COMBINE_EVENTS directive | COMPRESS_MACROS directive | DAWNDUSK_DEF directive | DAWN_OPTION directive | DUSK_OPTION directive | MIN_DAWN directive | MAX_DAWN directive | MIN_DUSK directive | MAX_DUSK directive | DAWN_SUBSTITUTE directive | DUSK_SUBSTITUTE directive | REPORT_PATH directive | WRITE_CHECK_FILES directive | REPL_DELAYED_MACROS directive | ASIF_DATE directive | ASIF_TIME directive | FEB_KLUGE directive | RESOLVE_OVERLAP directive | FIX_STOPSTART_ERROR directive | RF_POST_DELAY directive | RF_FARB_DELAY directive | RF_FARW_DELAY directive | RF_BURSTS directive | TIMER_LOOPCOUNT directive | CM17A_BIT_DELAY directive | DISPLAY_RF_XMIT directive | RF_NOSWITCH directive | TTY_AUX directive | SUPPRESS_RFXJAM directive | ALIAS directive | TRANSCEIVE directive | RFFORWARD directive | TRANS_DIMLEVEL directive | AUX_REPCOUNTS directive | DISPLAY_RAW_RF directive | SECURID_16 directive | SECURID_PARITY directive | HIDE_UNCHANGED directive | HIDE_UNCHANGED_INACTIVE directive | ORE_LOWBATTERY directive | ORE_CHGBITS_T directive | ORE_CHGBITS_RH directive | ORE_CHGBITS_BP directive | ELS_CHGBITS_CURR directive | OWL_CHGBITS_POWER directive | OWL_CHGBITS_ENERGY directive | OWL_DISPLAY_COUNT directive | ORE_DATA_ENTRY | ORE_DISPLAY_CHAN directive | ORE_DISPLAY_FCAST | ORE_DISPLAY_COUNT directive | RFXCOM_DISABLE directive | RFXCOM_ENABLE directive | ARM_MAX_DELAY directive | ARM_REMOTE directive | INACTIVE_TIMEOUT directive | INACTIVE_HANDLING directive. | ARM_LOGIC directive | CM11A_QUERY_DELAY directive | LOCK_TIMEOUT directive | DISPLAY_SENSOR_INTV directive | LOGDATE_UNIX directive | ORE_ID_16 directive. | ENGINE_POLL directive | RESTRICT_DIMS directive | POWERFAIL_UPDATE directive | AUTO_WAIT directive | ENVIRONMENT | AUTHORS | SEE ALSO