Skip site navigation (1)Skip section navigation (2)

FreeBSD Manual Pages

  
 
  

home | help
SNMPD.INTERNAL(5)		   Net-SNMP		     SNMPD.INTERNAL(5)

NAME
       snmpd.internal -	internal configuration of the Net-SNMP agent

DESCRIPTION
       The snmpd.conf(5) man page defines the syntax and behaviour of the main
       configuration directives	that can be used to control the	 operation  of
       the Net-SNMP agent, and the management information it provides.

       However	there  are  several  other  configuration  directives (many of
       which, though not all, start with a leading underscore) that are	recog-
       nised  by  the agent.  These are	typically used to retain configuration
       across agent restarts, and are not intended  for	 direct	 user  access.
       This man	page list these	directives, giving a brief indication of where
       they are	used.  For full	details	- see the relevant source  files.   If
       you  can't  follow that source, you probably shouldn't be fiddling with
       these directives!

AGENT BEHAVIOUR
       quit

ACCESS CONTROL
   VACM	Configuration
       vacmView	/ vacmGroup / vacmAccess
	      These directives are used	to retain dynamically  configured  ac-
	      cess control settings.

SYSTEM INFORMATION
   System Group
       setSerialNo
	      This directive is	used to	implement the advisory lock object sn-
	      mpSetSerialNo.

       psyslocation / psyscontact / psysname
	      These directives are used	to retain dynamically configured  sys-
	      tem settings.  They will be overridden by	the corresponding sys-
	      Location,	sysContact and sysName directives.

ACTIVE MONITORING
   Notification	Handling
       pauthtrapenable
	      This directive is	used to	retain the dynamically configured set-
	      ting  of whether the agent should	generate authenticationFailure
	      traps.  It will be overridden by the  corresponding  authtrapen-
	      able directive.

       snmpNotify*Table

       targetAddr / targetParams
	      These directives are used	to retain dynamically configured noti-
	      fication destination settings.

   DisMan Event	MIB
       _mteE*Table, _mteOTable,	_mteT*Table
	      These directives	are  used  to  retain  dynamically  configured
	      event, object and	monitor	trigger	settings.

       mteObjectsTable / mteTriggerTable
	      These  directives	 are  for compatibility	with the previous dis-
	      man/event-mib implementation.

   DisMan Schedule MIB
       _schedTable
	      This directive is	used to	retain dynamically  configured	sched-
	      uled events.

EXTENDING AGENT	FUNCTIONALITY
   Arbitrary Extension Commands
       extend-sh

       exec2 / sh2 / execFix2
	      These  directives	were defined by	analogy	with equivalent	direc-
	      tives in the previous ucd-snmp/extensible	implementation.	  They
	      are deprecated, and should not be	used.

FILES
       /usr/local/etc/snmp/snmpd.conf

SEE ALSO
       snmpconf(1), snmpd.conf(5), snmp.conf(5), snmp_config(5), snmpd(8), EX-
       AMPLE.conf, netsnmp_config_api(3).

V5.7.3				  06 Dec 2005		     SNMPD.INTERNAL(5)

NAME | DESCRIPTION | AGENT BEHAVIOUR | ACCESS CONTROL | SYSTEM INFORMATION | ACTIVE MONITORING | EXTENDING AGENT FUNCTIONALITY | FILES | SEE ALSO

Want to link to this manual page? Use this URL:
<https://www.freebsd.org/cgi/man.cgi?query=snmpd.internal&sektion=5&manpath=FreeBSD+12.2-RELEASE+and+Ports>

home | help