NAME
       sg_ses_microcode	- send microcode to a SCSI enclosure

SYNOPSIS
       sg_ses_microcode	 [--bpw=CS]  [--dry-run]  [--ealsd] [--help] [--id=ID]
       [--in=FILE]   [--length=LEN]   [--mode=MO]    [--non]	[--offset=OFF]
       [--skip=SKIP]  [--subenc=MS]  [--tlength=TLEN]  [--verbose] [--version]
       DEVICE

DESCRIPTION
       This utility attempts to	download microcode to an enclosure (or one  of
       its  sub-enclosures)  associated	with the DEVICE. The process for doing
       this is defined in the SCSI  Enclosure  Services	 (SES)	standards  and
       drafts maintained by the	T10 committee.

       The process is to send one or more sequences containing a SCSI SEND DI-
       AGNOSTIC	command	followed optionally by a  RECEIVE  DIAGNOSTIC  RESULTS
       command.	 The former sends a Download microcode Control diagnostic page
       (dpage) and the latter fetches a	Download microcode status dpage	 which
       can be viewed as	a report on the	former command.

       The  default action (i.e. when the --mode=MO option is not given) is to
       fetch the Download microcode status dpage and decode it.	This does  not
       require	the microcode (firmware) itself	so the --in=FILE option	is not
       required.

       The most	recent reference for this utility is the draft SCSI  Enclosure
       Services	3 (SES-3) document T10/2149-D Revision 7 at http://www.t10.org
       .  Existing standards for SES and SES-2 are ANSI	 INCITS	 305-1998  and
       ANSI INCITS 448-2008 respectively.

       Most  other support for SES in this package (apart from downloading mi-
       crocode)	can be found in	the sg_ses utility. Another way	of downloading
       firmware	 to  a SCSI device is with the WRITE BUFFER command defined in
       SPC-4, see the sg_write_buffer utility.

OPTIONS
       Arguments to long options are mandatory for short options as well.

       -b, --bpw=CS
	      where CS is the chunk size in bytes and should be	a multiple  of
	      4.  This will be the maximum number of bytes sent	per SEND DIAG-
	      NOSTIC command.  So if CS	is less	than the effective  length  of
	      the  microcode  then multiple SEND DIAGNOSTIC commands are sent,
	      each taking the next chunk from the read data and	increasing the
	      buffer  offset  field in the Download microcode control dpage by
	      the appropriate amount. The default is a chunk size of  0	 which
	      is  interpreted as a very	large number hence only	one SEND DIAG-
	      NOSTIC command will be sent.
	      The number in CS can optionally be followed by ",act" or ",acti-
	      vate".   In  this	case after the microcode has been successfully
	      sent to the DEVICE, an  additional  Download  microcode  control
	      dpage  with  its mode set	to "Activate deferred microcode" [0xf]
	      is sent.

       -d, --dry-run
	      the actual calls to perform SEND DIAGNOSTIC and RECEIVE DIAGNOS-
	      TIC  RESULTS  commands are skipped when this option is given. No
	      SCSI commands are	sent to	the DEVICE but it is still opened  and
	      is  required  to be given.  A dummy device such as /dev/null (in
	      Unix) can	be used.
	      This utility expects a "sensible"	response to the	RECEIVE	 DIAG-
	      NOSTIC  RESULTS  command	it sends (and will abort if it doesn't
	      receive one). So this option supplies dummy responses  with  one
	      primary  enclosure and three sub-enclosures. The dummy responses
	      include good status values.

       -e, --ealsd
	      exit after last SEND DIAGNOSTIC command. A SES device should not
	      start  its  firmware  update immediately after the last received
	      "chunk" of its firmware.	Rather it should wait  till  at	 least
	      one  RECEIVE  DIAGNOSTIC RESULTS command is sent to give the de-
	      vice a chance to report any error. However some devices do start
	      the  firmware  update  immediately which causes the trailing RE-
	      CEIVE DIAGNOSTIC RESULTS command to be  held  up	and  often  be
	      aborted with a "target reset" error.
	      This  option causes the trailing RECEIVE DIAGNOSTIC RESULTS com-
	      mand to be skipped. This option would be typically used with the
	      --bpw=CS option.
	      Prior  to	 version  1.10	of  this utility [20180112] this (i.e.
	      skipping the last	RECEIVE	DIAGNOSTIC RESULTS  command)  was  the
	      default action.

       -h, --help
	      output  the usage	message	then exit. If used multiple times also
	      prints the mode names and	their acronyms.

       -i, --id=ID
	      this option sets the BUFFER ID field in the  Download  microcode
	      control  dpage. ID is a value between 0 (default)	and 255	inclu-
	      sive.

       -I, --in=FILE
	      read data	from file FILE that will be sent with the  SEND	 DIAG-
	      NOSTIC  command.	If FILE	is '-' then stdin is read until	an EOF
	      is detected (this	is the same action as  --raw).	Data  is  read
	      from the beginning of FILE except	in the case when it is a regu-
	      lar file and the --skip=SKIP option is given.

       -l, --length=LEN
	      where LEN	is the length, in bytes, of data to be written to  the
	      device.	If  not	 given	(and the length	cannot be deduced from
	      --in=FILE	or --raw) then defaults	to  zero.  If  the  option  is
	      given and	the length deduced from	--in=FILE or --raw is less (or
	      no data is provided), then bytes of 0xff are used	as fill	bytes.

       -m, --mode=MO
	      this option sets the MODE. MO is a value	between	 0  (which  is
	      dmc_status  and the default) and 255 inclusive. Alternatively an
	      abbreviation can be given. See the MODES section below. To  list
	      the available mode abbreviations at run time give	an invalid one
	      (e.g. '--mode=xxx') or use the '-h' option.

       -N, --non
	      allow for	non-standard implementations that reset	their Download
	      microcode	engine after a RECEIVE DIAGNOSTIC RESULTS command with
	      the Download microcode status dpage is sent. When	this option is
	      given  sending that command and dpage combination	is avoided un-
	      less an error has	already	occurred.

       -o, --offset=OFF
	      this option sets the BUFFER OFFSET field	in  the	 Download  mi-
	      crocode  control	dpage.	OFF is a value between 0 (default) and
	      2**32-1 .	It is a	byte offset. This option  is  ignored  (and  a
	      warning sent to stderr) if the --bpw=CS option is	also given.

       -s, --skip=SKIP
	      this option is only active when --in=FILE	is given and FILE is a
	      regular file, rather than	stdin. Data is read starting  at  byte
	      offset  SKIP  to	the  end  of  file  (or	 the  amount  given by
	      --length=LEN).  If not given the byte offset defaults to 0 (i.e.
	      the start	of the file).

       -S, --subenc=SEID
	      SEID  is	the  sub-enclosure identify. It	defaults to 0 which is
	      the primary enclosure identifier.

       -t, --tlength=TLEN
	      TLEN is the total	length in bytes	of the microcode to be (or be-
	      ing)  downloaded.	 It defaults to	0 which	is okay	in most	cases.
	      This option only comes into play when TLEN is greater than  LEN.
	      In  this	case  TLEN  is sent to the SES DEVICE so that it knows
	      when it only receives LEN	bytes from this	 invocation,  that  it
	      should  expect  more  to be sent in the near future (e.g.	by an-
	      other invocation). This option is	only needed when  sections  of
	      microcode	are being sent in separate invocations of this utility
	      (e.g. the	microcode is spread across two files).

       -v, --verbose
	      increase the level of verbosity, (i.e. debug output).

       -V, --version
	      print the	version	string and then	exit.

MODES
       Following is a list accepted by the MO argument of this utility.	 First
       shown  is  an  acronym followed in square brackets by the corresponding
       decimal and hex values that may also be given for MO.

       dmc_status  [0, 0x0]
	      Use RECEIVE DIAGNOSTIC RESULTS to	fetch the  Download  microcode
	      status dpage and print it	out.

       dmc_offs	 [6, 0x6]
	      Download microcode with offsets and activate.

       dmc_offs_save  [7, 0x7]
	      Download microcode with offsets, save, and activate.

       dmc_offs_defer  [14, 0xe]
	      Download microcode with offsets, save, and defer activate.

       activate_mc  [15, 0xf]
	      Activate deferred	microcode. There is no follow-up RECEIVE DIAG-
	      NOSTIC RESULTS to	fetch  the  Download  microcode	 status	 dpage
	      since the	DEVICE might be	resetting.

       Apart  from dmc_status, these are placed	in the Download	microcode mode
       field in	the Download microcode control dpage. In the case of  dmc_sta-
       tus the Download	microcode status dpage is fetched with the RECEIVE DI-
       AGNOSTIC	RESULTS	command	and decoded.

WHEN THE DOWNLOAD FAILS
       Firstly,	if it succeeds,	this utility should stay  silent  and  return.
       Typically vendors will change the "revision" string (which is 4 charac-
       ters long) whenever they	release	new firmware. That can be seen in  the
       response	 to  a	SCSI  INQUIRY command, for example by using the	sg_inq
       utility.	 It is possible	that the device	needs to be power  cycled  be-
       fore  the  new  microcode  becomes  active. Also	if mode	dmc_offs_defer
       [0xe] is	used to	download the microcode,	then another  invocation  with
       activate_mc may be needed.

       If  something  goes wrong, there	will typically be messages printed out
       by this utility.	The first thing	to check is the	 microcode  (firmware)
       file  itself.  Is  it  designed	for the	device model; has it been cor-
       rupted, and if downgrading (i.e.	trying to reinstate  older  firmware),
       does the	vendor allow that?

       Getting	new  firmware  on a device is a	delicate operation that	is not
       always well defined by T10's standards and drafts. One might  speculate
       that  they are deliberately vague. In testing this utility one vendor's
       interpretation of the standard was somewhat surprising. The  --non  op-
       tion  was added to cope with their interpretation. So if	the above sug-
       gestions	don't help, try	adding the --non option.

NOTES
       This utility can	handle a maximum size of 128  MB  of  microcode	 which
       should be sufficient for	most purposes. In a system that	is memory con-
       strained, such large allocations	of memory may fail.

       The user	should be aware	that most operating systems have limits	on the
       amount  of  data	 that can be sent with one SCSI	command. In Linux this
       depends on the pass through mechanism used (e.g.	block SG_IO or the  sg
       driver) and various setting in sysfs in the Linux lk 2.6/3 series (e.g.
       /sys/block/sda/queue/max_sectors_kb). Devices (i.e. logical units) also
       typically  have limits on the maximum amount of data they can handle in
       one command. These two limitations suggest that	modes  containing  the
       word  "offset"  together	 with  the  --bpw=CS  option  are  required as
       firmware	files get larger and larger. And CS can	be  quite  small,  for
       example	4096  bytes,  resulting	in many	SEND DIAGNOSTIC	commands being
       sent.

       The exact error from the	non-standard implementation was	a sense	key of
       ILLEGAL	REQUEST	 and  an  asc/ascq  code of 0x26,0x0 which is "Invalid
       field in	parameter list". If that is seen try again with	the --non  op-
       tion.

       Downloading incorrect microcode into a device has the ability to	render
       that device inoperable. One would hope that the device vendor  verifies
       the data	before activating it.

       A  long	(operating system) timeout of 7200 seconds is set on each SEND
       DIAGNOSTIC command.

       All numbers given with options are assumed  to  be  decimal.   Alterna-
       tively  numerical values	can be given in	hexadecimal preceded by	either
       "0x" or "0X" (or	has a trailing "h" or "H").

EXAMPLES
       If no microcode/firmware	file is	given then this	 utility  fetches  and
       decodes	the  Download microcode	status dpage which could possibly show
       another initiator in the	process	of updating  the  microcode.  Even  if
       that  is	happening, fetching the	status page should not cause any prob-
       lems:

	 sg_ses_microcode /dev/sg3
       Download	microcode status diagnostic page:
	 number	of secondary sub-enclosures: 0
	 generation code: 0x0
	  sub-enclosure	identifier: 0 [primary]
	    download microcode status:	No  download  microcode	 operation  in
       progress	[0x0]
	    download microcode additional status: 0x0
	    download microcode maximum size: 1048576 bytes
	    download microcode expected	buffer id: 0x0
	    download microcode expected	buffer id offset: 0

       The  following  sends new microcode/firmware to an enclosure. Sending a
       1.5 MB file in one command caused the enclosure to lock up  temporarily
       and  did	 not update the	firmware. Breaking the firmware	file into 4 KB
       chunks (an educated guess) was more successful:

	 sg_ses_microcode -b 4k	-m dmc_offs_save -I firmware.bin /dev/sg4

       The firmware update occurred in the following  enclosure	 power	cycle.
       With a modern enclosure the Extended Inquiry VPD	page gives indications
       in which	situations a firmware upgrade will take	place.

EXIT STATUS
       The exit	status of sg_ses_microcode is 0	when it	is successful.	Other-
       wise see	the sg3_utils(8) man page.

AUTHORS
       Written by Douglas Gilbert.

REPORTING BUGS
       Report bugs to <dgilbert	at interlog dot	com>.

COPYRIGHT
       Copyright (C) 2014-2018 Douglas Gilbert
       This  software is distributed under a FreeBSD license. There is NO war-
       ranty; not even for MERCHANTABILITY or FITNESS FOR  A  PARTICULAR  PUR-
       POSE.

SEE ALSO
       sg_ses, sg_write_buffer,	sg_inq(sg3_utils)

sg3_utils-1.43			 January 2018		   SG_SES_MICROCODE(8)