sensor.conf(5)			SiLK Tool Suite			sensor.conf(5)

NAME
       sensor.conf - Sensor Configuration file for rwflowpack and flowcap

DESCRIPTION
       As part of collecting flow data,	the rwflowpack(8) and flowcap(8)
       daemons need to know what type of data they are collecting and how to
       collect it (e.g., listen	on 10000/udp for NetFlow v5; listen on
       4740/tcp	for IPFIX).  In	addition, the rwflowpack daemon	needs
       information on how to categorize	the flow: for example, to label	the
       flows collected at a border router as incoming or outgoing.  The	Sensor
       Configuration file, sensor.conf,	contains this information, and this
       manual page describes the syntax	of the file (see "SYNTAX" below) and
       provides	some example configurations (see "EXAMPLES").

       The sensor.conf file may	have any name, and it may reside in any
       location.  The name and location	of the file is specified by the
       --sensor-configuration switch to	rwflowpack and flowcap.

       The Sensor Configuration	File defines the following concepts:

       probe
	   A probe specifies a source for flow data.  The source could be a
	   port	on which flowcap or rwflowpack collects	NetFlow	or IPFIX data
	   from	a flow generator such as a router or the yaf software
	   (<http://tools.netsa.cert.org/yaf/>).  In rwflowpack, the source
	   can be a directory to periodically poll for files containing
	   NetFlow v5 PDUs, IPFIX records, or SiLK Flow	records.  When
	   defining a probe, you must specify a	unique name for	the probe and
	   the probe's type.

       group
	   A group is a	named list that	contains one of	the following: CIDR
	   blocks, the names of	IPset files, or	integers representing SNMP
	   interfaces or VLAN identifiers.  The	use of groups is optional; the
	   primary purpose of a	group is to allow the administrator to specify
	   a commonly used list	(such as the IP	space of the network being
	   monitored) in a single location.

       sensor
	   A sensor represents a logical collection point for the purposes of
	   analysis.  The sensor contains configuration	values that rwflowpack
	   uses	to categorize each flow	record depending on how	the record
	   moves between networks at the collection point.  Since the sensors
	   and the categories (known as	flowtypes or as	class/type pairs) are
	   also	used for analysis, they	are defined in the Site	Configuration
	   file, described in silk.conf(5).  The Sensor	Configuration file
	   maps	sensors	to probes and specifies	the rules required to
	   categorize the data.	 Usually one sensor corresponds	to one probe;
	   however, a sensor may be comprised of multiple probes, or the flow
	   data	collected at a single probe may	be handled by multiple
	   sensors.

       The next	section	of this	manual page describes the syntax of the
       sensor.conf file.

       Using the syntax	to configure a sensor requires knowledge of the
       packing logic that rwflowpack is	using.	The packing logic is the set
       of rules	that rwflowpack	uses to	assign a flowtype to each record it
       processes.  The default packing logic is	for the	twoway site, which is
       described in the	packlogic-twoway(3) manual page.  Additional packing
       logic rules are available (e.g.,	packlogic-generic(3)).

       The last	major section of this document is "EXAMPLES" where several
       common configurations are shown.	 These examples	assume rwflowpack is
       using the packing logic from the	twoway site.

SYNTAX
       When parsing the	Sensor Configuration file, blank lines are ignored.
       At any location in a line, the character	"#" indicates the beginning of
       a comment, which	continues to the end of	the line.  These comments are
       ignored.

       All other lines begin with optional leading whitespace, a command name,
       and one or more arguments to the	command.  Command names	are a sequence
       of non-whitespace characters, not including the character "#".
       Arguments are textual atoms: any	sequence of non-whitespace, non-"#"
       characters, including numerals and punctuation.

       There are four contexts for commands: top-level,	probe block, group
       block, and sensor block.	 The probe block, group	block, and sensor
       block contexts are used to describe individual features of probes,
       groups, and sensors, respectively.

       The valid commands for each context are described below.

   Top-Level Commands
       In addition to the commands to begin a probe, group, or sensor block,
       the top-level context supports the following command:

       include "path"
	   The include command is used to include the contents of another file
	   whose location is path.  This may be	used to	separate large
	   configurations into logical units.  The argument to include must be
	   a double-quoted string.

   Probe Block
       With the	exception of the probe command,	the commands listed below are
       accepted	within the probe context.  Within a probe block, one and only
       one of the following must be specified: listen-on-port to listen	on a
       network socket, poll-directory to poll a	directory for files, read-
       from-file to read a single file,	or listen-on-unix-socket to listen on
       a UNIX domain socket.  These commands are described below.

       probe probe-name	probe-type
	   The probe command is	used in	the top-level context to begin a new
	   probe block which continues to the end probe	command.  The
	   arguments to	the probe command are the name of the probe being
	   defined and the probe type.	The probe-name must be unique among
	   all probes.	It must	begin with a letter, and it may	not contain
	   whitespace characters or the	slash character	("/").	When a probe
	   is associated with a	single sensor, it is good practice to give the
	   probe the same name as the sensor.  The probe-type must be one of
	   the following:

	   netflow-v5
	       This probe processes NetFlow v5 protocol	data units (PDU) that
	       the daemon reads	from a UDP port	or from	a file.	 NetFlow may
	       be generated by a router	or by software that reads packet
	       capture (pcap(3)) data and generates NetFlow v5 records.

	   netflow
	       This is an alias	for netflow-v5 for backwards compatibility.
	       This alias is deprecated, and it	may be removed in a future
	       release.

	   ipfix
	       An IPFIX	probe processes	Internal Protocol Flow Information
	       eXchange	records	that the daemon	reads over the network from an
	       IPFIX source such as yaf(1).  An	IPFIX probe can	also poll a
	       directory for files generated by	the yaf	program.  To support
	       IPFIX probes, SiLK must be built	with support for the external
	       library libfixbuf, version 1.7.0	or later.  Both	yaf and
	       libfixbuf are available from <http://tools.netsa.cert.org/>.

	   netflow-v9
	       This probe processes NetFlow v9 protocol	data units (PDU) that
	       the daemon reads	from a UDP port	from a router.	To support
	       NetFlow v9 probes, SiLK must be built with support for the
	       external	library	libfixbuf, version 1.7.0 or later.

	   sflow
	       This probe processes sFlow v5 records that the daemon reads
	       from a UDP port.	 To support sFlow probes, SiLK must be built
	       with support for	the external library libfixbuf,	version	1.7.0
	       or later.  Since	SiLK 3.9.0.

	   silk
	       A SiLK probe processes the records contained in SiLK Flow files
	       created by previous invocations of rwflowpack.  The flows will
	       be completely re-packed,	as if they were	just received over the
	       network.	 The sensor and	flowtype values	in each	flow will be
	       ignored.	 Note that SiLK	usually	removes	the SNMP interfaces
	       from its	flow records, and it is	likely that you	will be	unable
	       to use the SNMP interfaces to pack the flows.

       end probe
	   The end probe command ends the definition of	a probe.  Following an
	   end probe command, top-level	commands are again accepted.

       listen-on-port port
	   This	command	configures the probe to	accept flow records over the
	   network, and	port specifies the network port	number where the probe
	   should listen for flow data.	 The protocol command is required when
	   listen-on-port is specified,	and the	listen-as-host and accept-
	   from-host commands are optional.  Multiple probes may use the same
	   value for port as long as the probes	are the	same type and the
	   accept-from-host command is specified in each probe block.  Probes
	   of different	types may not bind to the same port, meaning the
	   combination of the following	three values must be different:
	   listen-on-port, protocol, and listen-as-host.  When listening to
	   IPFIX data from yaf,	this is	the value specified to yaf's
	   --ipfix-port	switch.	 When listening	to NetFlow from	a Cisco
	   router, this	is the port that was specified to the Cisco IOS
	   command

	    ip flow-export [ip-address]	[port]

       protocol	{ tcp |	udp }
	   This	command, required when listen-on-port is given,	specifies
	   whether the port is a "tcp" or "udp"	port.  IPFIX probes support
	   both	types; the only	permitted value	for all	other probe types is
	   "udp".  When	listening to IPFIX data	from yaf, this is the value
	   specified to	yaf's --ipfix switch.

       accept-from-host	host-name [host-name...]
	   This	optional command specifies the hosts that are allowed to
	   connect to the port where the probe is listening.  The argument is
	   a list of IP	addresses and/or hostnames separated by	whitespace
	   and/or a comma.  When this command is not present, any host may
	   connect.  The command may only be specified when the	listen-on-port
	   command is also present.  When multiple probes use the same listen-
	   on-port, protocol, and listen-as-host values, the accept-from-host
	   switch must be used so that rwflowpack may assign incoming records
	   to a	specified probe.  When listening for NetFlow, this attribute
	   would be the	IP address of the router as seen from the machine
	   running rwflowpack or flowcap.  (Prior to SiLK 3.10.1, the accept-
	   from-host command accepted only a single argument.)

       listen-as-host host-name
	   This	optional command is used on a multi-homed machine to specify
	   the address the probe should	listen on (bind(2) to).	 Its value is
	   the name of the host	or its IP address.  If not present, the
	   program will	listen on all the machine's addresses.	The command
	   may only be specified when the listen-on-port command is also
	   present.  For listening to NetFlow, the value would be the ip-
	   address that	was specified to the Cisco IOS command

	    ip flow-export [ip-address]	[port]

       listen-on-unix-socket path-to-unix-socket
	   The value contains the path name to a UNIX domain socket where the
	   flow	generator writes its data.  The	parent directory of path-to-
	   unix-socket must exist.  Multiple probes may	not use	the same path-
	   to-unix-socket.

       poll-directory directory-path
	   When	this command is	given, rwflowpack will periodically poll the
	   directory-path to look for files to process.	 flowcap will exit
	   with	an error if you	attempt	to use probes that contain this
	   command since flowcap does not support reading data from files.
	   Multiple probes may not use the same	directory-path.	 When polling
	   the directory, zero length files and	files whose name begin with a
	   dot (".") are ignored.  This	command	may be used with the following
	   probe types:

	   o   For SiLK	probes,	each file must be a valid SiLK Flow file.

	   o   IPFIX probes can	process	files created by the yaf program.

	   o   A NetFlow v5 probe will process files containing	NetFlow	v5
	       PDUs.  The format of these files	is specified in	the
	       description of the read-from-file command.

       read-from-file dummy-value
	   When	this command is	given, rwflowpack will read NetFlow v5 records
	   from	the file specified by the --netflow-file command line switch.
	   The value to	the read-from-file command is completely ignored, and
	   we recommend	you use	"/dev/null" as the value.  flowcap will	exit
	   with	an error if you	attempt	to use probes that contain this
	   command since flowcap does not support reading data from files.
	   The format of a NetFlow v5 file is that the file's length should be
	   an integer multiple of 1464 bytes, where 1464 is the	maximum	length
	   of the NetFlow v5 PDU.  Each	1464 block should contain the 24-byte
	   NetFlow v5 header and space for thirty 48-byte flow records,	even
	   if fewer NetFlow records are	valid.	rwflowpack will	accept NetFlow
	   v5 files that have been compressed with the gzip(1) program.

       log-flags { none	| { all	| bad |	default	| firewall-event | missing |
       record-timestamps | sampling | show-templates | ... } }
	   This	optional command accepts a comma- and/or space-separated list
	   of names that specify which messages	to log for this	probe.	If not
	   specified, the default is default, which is equivalent to bad,
	   missing, sampling.  The possible values are:

	   all Log everything.

	   bad Write messages about an individual NetFlow v5 record where the
	       packet or octet count is	zero, the packet count is larger than
	       the octet count,	or the duration	of the flow is larger than 45
	       days.

	   default
	       Enable the following values: bad, missing, sampling.  This is
	       the default value.  Since SiLK 3.10.0.  (Prior to SiLK 3.10.0,
	       all was the default.)

	   firewall-event
	       When the	"firewall-event" quirks	flag is	set and	the probe is
	       processing NetFlow v9 or	IPFIX, write messages about records
	       that are	ignored	because	the firewall event information element
	       on the record is	something other	than flow deleted or flow
	       denied.	Since SiLK 3.8.1.

	   missing
	       Examine the sequence numbers of NetFlow v5 packets and write
	       messages	about missing and out-of-sequence packets.  (You may
	       suppress	messages regarding out-of-sequence NetFlow v9 or IPFIX
	       packets for all probes by setting the
	       SILK_LIBFIXBUF_SUPPRESS_WARNINGS	environment variable.)

	   none
	       Log nothing.  It	is an error to combine this value with any
	       other.

	   record-timestamps
	       Log the timestamps that appear on each record.  This produces a
	       lot of output, and it is	primarily used for debugging.  Since
	       SiLK 3.10.0.

	   sampling
	       Write messages constructed by parsing the NetFlow v9 Options
	       Templates that specify the sampling algorithm (when
	       samplingAlgorithm and samplingInterval IEs are present) or flow
	       sampler mode (when flowSamplerMode and
	       flowSamplerRandomInterval IEs are present).  Since SiLK 3.8.0.

	   show-templates
	       Write messages to the log file describing each IPFIX template
	       that is read by this file-base or TCP probe.  (UDP probes must
	       still rely on the SILK_IPFIX_PRINT_TEMPLATES environment
	       variable.)  The message contains	embedded new lines, with the
	       template	ID and domain on the first line, and each of the
	       template's elements on the following lines.  Each element is
	       described by its	name, its IE number with the private
	       enterprise number if any, and its length	in the template.
	       Scope elements in options templates are marked.	The format is
	       that described in Section 10.2 of RFC7013
	       <https://tools.ietf.org/html/rfc7013>.  Since SiLK 3.19.0.

       interface-values	{ snmp | vlan }
	   This	optional command specifies the values that should be stored in
	   the "input" and "output" fields of the SiLK Flow records that are
	   read	from the probe.	 If this command is not	given, the default is
	   snmp.  Note that NetFlow v5 probes only support snmp.

	   snmp
	       Store the index of the network interface	card (ifIndex) where
	       the flows entered and left the router, respectively.

	   vlan
	       Store the VLAN identifier for the source	and destination
	       networks, respectively.	If only	one VLAN ID is available,
	       "input" is set to that value and	"output" is set	to 0.

	   This	setting	does not affect	whether	rwflowpack(8) stores the
	   "input" and "output"	fields to its output files.  Storage of	those
	   fields is controlled	by rwflowpack's	--pack-interfaces switch.

       quirks {	none | { firewall-event	| missing-ips |	nf9-out-is-reverse |
       nf9-sysuptime-seconds | zero-packets ...	} }
	   This	optional command is used to indicate that special (or quirky)
	   handling of the incoming data is desired.  The value	none disables
	   all quirks, and that	is the default setting.	 If the	value is not
	   none, it may	be a list of one or more of the	values specified below
	   separated by	commas and/or spaces.  Since SiLK 3.8.0.

	   firewall-event
	       Enable checking for firewall event information elements (IEs)
	       when processing IPFIX or	NetFlow	v9 flow	records.  This quirk
	       must be enabled when collecting data from a Cisco ASA.  The
	       IPFIX firewallEvent IE is 233.  The Cisco elements are
	       NF_F_FW_EVENT (IE 40005)	and NF_F_FW_EXT_EVENT (IE 33002).
	       When this quirk is active, firewall events that match the value
	       2 (flow deleted)	are categorized	as normal flows, firewall
	       events that match the value 3 (flow denied) are usually put
	       into one	of non-routed types (e.g., innull, outnull, see
	       packlogic-twoway(3) and packlogic-generic(3) for	details), and
	       all other firewall events values	are dropped.  (Note that a log
	       message is generated for	these dropped records; to suppress
	       these messages, use the log-flags command.)  When this quirk is
	       not provided, SiLK handles these	records	normally, which	may
	       result in duplicate flow	records.  (Prior to SiLK 3.8, SiLK
	       dropped all flow	records	that contained a firewall event	IE.)
	       Since SiLK 3.8.0.

	   missing-ips
	       Store a flow record even	when the record's NetFlow v9/IPFIX
	       template	does not contain IP addresses.	One change in SiLK
	       3.8.0 was to ignore flow	records	that do	not have a source
	       and/or destination IP address; this quirk allows	one to undo
	       the effect of that change.  Since SiLK 3.8.1.

	   nf9-out-is-reverse
	       Change handling of the OUT_BYTES	and OUT_PKTS information
	       elements	to match that in libfixbuf prior to 1.8.0.
	       Specifically, treat information elements	23 and 24 (OUT_BYTES
	       and OUT_PKTS in RFC3954)	as reverseOctetDeltaCount and
	       reversePacketDeltaCount,	respectively.  Starting	with
	       libfixbuf-1.8.0,	those NetFlow v9 elements are mapped to
	       postOctetDeltaCount and postPacketDeltaCount, respectively.
	       Since SiLK 3.17.2.

	   nf9-sysuptime-seconds
	       Work around an issue with NetFlow v9 records created by some
	       middleboxes (e.g., SonicWall) where the sysUpTime field in the
	       packet header is	reported in seconds instead of in
	       milliseconds.  The incorrect units cause	the time stamps	on
	       flow records to be future dated.	 In addition, adjust the time
	       fields on single	packet flow records.  Since SiLK 3.14.0.

	   none
	       Do not enable any quirks.

	   zero-packets
	       Enable support for flow records either that do not contain a
	       valid packets field, such as those from the Cisco ASA series of
	       routers,	or that	have an	unusually large	bytes-per-packet
	       ratio.  When this quirk is active, SiLK sets the	packet count
	       to 1 when the incoming IPFIX or NetFlow v9 flow record has a
	       the packet count	if 0.  This quirk may modify the file format
	       used by rwflowpack for IPv4 records in order to support large
	       byte-per-packet ratios.	Since SiLK 3.8.0.

       priority	value
	   This	optional command is deprecated.	 It exists for backwards
	   compatibility and will be removed in	the next major release.

       To summarize the	probe types and	the input they can accept:

	Probe Type   Berkeley	 Directory  UnixDomain	  Single
		      Socket	  Polling     Socket	   File
	==========  ==========	==========  ==========	==========
	ipfix	     tcp/udp	    yes
	netflow-v5     udp	    yes			   yes
	netflow-v9     udp
	sflow	       udp
	silk			    yes

   Lists of CIDR Blocks, IPsets, or Integers
       This subsection describes the syntax of a list of CIDR blocks, a	list
       of IPset	file names, and	a list of integers.  These lists are used in
       the sensor block	and group block	commands described below.

       A group block (see "Group Block") allows	you to assign names to these
       lists.  Once the	name is	defined, it may	be referenced in other lists
       of the same type	by prepending the "at" character ("@") to the group's
       name.

       The lists are:

       cidr-block-list
	   A cidr-block-list (or ipblock-list) contains	one or more CIDR
	   blocks or group references that represent an	address	space.
	   Adjacent values in the list may be separated	by multiple whitespace
	   (space or tab) characters and/or a single comma.  When IPv4 and
	   IPv6	addresses combined, IPv4 addresses are mapped into the
	   ::ffff:0:0/96 netblock.  For	lists containing more than a few CIDR
	   blocks, consider using an IPset list	instead.

       ipset-list
	   An ipset-list contains the path names of one	or more	binary IPset
	   files or group references.  To create an IPset file,	use the
	   rwsetbuild(1) tool.	Each path name may be a	double-quoted string
	   ("example");	the quote characters are not necessary if the path
	   name	does not contain whitespace or any special characters (single-
	   quote "'", double-quote """,	comma ",", or pound "#").  Adjacent
	   values in the list may be separated by multiple whitespace (space
	   or tab) characters and/or a single comma.  When multiple IPset
	   files are specified,	a new IPset is created in memory and the
	   contents of the files are merged into it.  rwflowpack(8) exits with
	   an error if the IPset file does not exist or	does not contain any
	   IP addresses.  Since	SiLK 3.10.0.

       interface-list
	   An interface-list contains one or more integers between 0 and
	   65535, inclusive, or	group references or that represent SNMP
	   interface indexes or	VLAN identifiers.  Adjacent values in the list
	   may be separated by multiple	whitespace (space or tab) characters
	   and/or a single comma.

   Group Block
       The use of group	blocks is optional.  They are a	convenience to define
       and give	a name to a list of commonly used CIDR blocks, IPset files, or
       integer values that are treated as SNMP interfaces or VLAN identifiers.
       Groups may be used in sensor blocks ("Sensor Block") as described in
       the descriptions	for the	discard-when, discard-unless, network-
       name-ipblocks, network-name-ipsets and network-name-interfaces
       commands, below.

       The commands in a group definition must all be of the same type.	 For
       example,	you cannot mix ipblocks	and ipsets commands in a single	group
       definition, even	though both contain IP addresses.

       The contents of an existing group may be	added to the current group
       block by	using a	group reference	after the appropriate keyword as long
       as both groups are the same type.  A group reference is the name	of the
       group prefixed by the "at" character ("@").  When a group reference is
       used, the contents of the existing groups are copied into the current
       group.

       For examples of group blocks, see "Group	definitions" below.

       The group command is used at top-level to begin a group definition
       block, and the remaining	commands are accepted within the group block.

       group group-name
	   The group command begins a new group	definition block which
	   continues to	the end	group command.	The argument to	the group
	   command is the name of the group being defined.  The	group-name
	   must	be unique among	all groups.  It	must begin with	a letter, and
	   it may not contain whitespace characters or the slash character
	   ("/").

       end group
	   The end group command ends the definition of	a group.  Following an
	   end group command, top-level	commands are again accepted.

       interfaces interface-list
	   The interfaces command adds integer values to a group, where	each
	   integer is treated as an SNMP interface number or VLAN identifier.
	   An interface-list is	a list of integers or group references as
	   defined above ("Lists of CIDR Blocks, IPsets, or Integers").	 The
	   interfaces command may appear multiple times	in a group block.

       ipblocks	cidr-block-list
	   The ipblocks	command	adds CIDR block	values to a group.  The	cidr-
	   block-list is described above.  The ipblocks	command	may appear
	   multiple times in a group block.

       ipsets ipset-list
	   The ipset command adds the IP addresses specified in	an IPset file
	   to a	group.	The ipsets command may appear multiple times in	a
	   group block.	 Since SiLK 3.10.0.

   Sensor Block
       The information from the	sensor block is	used by	rwflowpack to
       determine how to	categorize a flow; that	is, in which file the flow
       record is stored.  The packlogic-twoway(3) manual page describes	how
       rwflowpack may use the sensor blocks to determine a record's category.

       When the	Sensor Configuration file is used with flowcap,	no sensors
       need to be defined.  In fact, flowcap completely	ignores	all text
       inside each sensor block.

       The sensor block	works with the packing logic to	determine where
       rwflowpack stores flow records.	The packing logic plug-in specifies a
       list of network names, and you will refer to these networks when	you
       configure the sensor block.  Most plug-ins provide the "external",
       "internal", and "null" names, where internal refers to network being
       monitored, null are flows that were blocked by the router's access
       control list, and external is everything	else.

       Several of the commands described below that categorize flow records
       require as an argument a	list of	CIDR blocks, a list of IPset files, or
       a list of integers.  The	syntax of these	lists is described in the
       "Lists of CIDR Blocks, IPsets, or Integers" section above.

       As part of  determining how to process a	flow record, rwflowpack	may
       check a record's	source or destination IP address against a cidr-block-
       list or an ipset-set.  Note the following:

       o   for a cidr-block-list, the IP address is sequentially compared to
	   each	element	of the list, stopping once a match is made

       o   when	comparing an IPv4 address to an	IPv6 list, the IPv4 address is
	   converted to	IPv6 by	mapping	it into	the ::ffff:0:0/96 prefix for
	   purposes of the comparison

       o   when	comparing an IPv6 address to an	IPv4 list, an IPv6 address in
	   the ::ffff:0:0/96 prefix is converted to IPv4 for purposes of the
	   comparison and any other IPv6 address fails the comparison

       As part of determining how to process a flow record, rwflowpack may
       check whether the record's "input" or "output" fields are an interface-
       list.  Whether the "input" and "output" fields contain SNMP interfaces
       or VLAN identifiers is determined by the	interface-values command in
       the probe block (c.f. "Probe Block").

       The sensor command is used in the top-level context to begin a sensor
       configuration block, and	the remaining commands are accepted within the
       sensor block.

       sensor sensor-name
	   The sensor command begins a new sensor configuration	block.	It
	   takes as an argument	the name of the	sensor being configured, and
	   that	sensor must be defined in the Site Configuration file (see
	   silk.conf(5)).  A sensor block is closed with the end sensor
	   command.  You may have multiple sensor blocks that have the same
	   sensor-name.

       end sensor
	   The end sensor command ends the configuration of a sensor.
	   Following an	end sensor command, top-level commands are again
	   accepted.

       probe-type-probes probe-name [probe-name	...]
	   This	command	associates the listed probe names of the given probe
	   type	with the sensor.  The probes do	not have to be defined before
	   they	are used.  (Note this also means that a	mistyped probe-name
	   will	not be detected.)  For example,	netflow-v5-probes S1 says that
	   S1 is a netflow-v5 probe; whenever flow data	arrives	on the S1
	   probe, the sensor associated	with the probe notices that data is
	   available and processes it.	Adjacent probe names in	the argument
	   list	may be separated by space or tab characters and/or a single
	   comma.

       source-network network-name
	   This	command	causes the sensor to assume that all flows originated
	   from	the network named network-name.	 For example, if a sensor is
	   associated a	probe that only	monitors incoming traffic, you could
	   use "source-network external" to specify that all traffic
	   originated from the external	network.

       destination-network network-name
	   This	command	causes the sensor to assume that all flows were	sent
	   to the network named	network-name.

       network-name-ipblocks {cidr-block-list |	remainder}
	   This	command	specifies the IP-space that is assigned	to the network
	   named network-name.	The value of the command can be	the keyword
	   remainder or	a cidr-block-list as defined above.  When the value is
	   the keyword remainder, the IP-space for network-name	is
	   conceptually	all IPs	not assigned to	other networks on this sensor.
	   The remainder keyword may only appear one time within a sensor
	   block.

       network-name-ipsets {ipset-list | remainder}
	   This	command	specifies the IP-space that is assigned	to the network
	   named network-name.	The value of the command can be	the keyword
	   remainder or	an ipset-list as defined above.	 When the value	is the
	   keyword remainder, the IP-space for network-name is conceptually
	   all IPs not assigned	to other networks on this sensor.  The
	   remainder keyword may only appear one time within a sensor block.

       network-name-interfaces {interface-list | remainder}
	   This	command	specifies the SNMP interface index(es) or VLAN
	   identifiers that are	assigned to the	network	named network-name.
	   The value of	the command may	be the keyword remainder or an
	   interface-list as defined above.  When the value is the keyword
	   remainder, the interface list is computed by	finding	all interface
	   values not assigned to other	networks on this sensor.  The
	   remainder keyword may only appear one time within a sensor block.

       isp-ip ip-address [ip-address ...]
	   This	optional command may be	used for a sensor that processes
	   NetFlow data.  The value to the command is a	list of	IP addresses
	   in dotted-decimal notation, where the IPs are the addresses of the
	   NICs	on the router.	For traffic that doesn't leave the router (and
	   thus	was sent to the	router's null-interface), some packing-logic
	   plug-ins use	these IPs to distinguish legitimate traffic for	the
	   router (e.g., routing protocol traffic, whose destination address
	   would be in this list) from traffic that violated the router's
	   access control list (ACL).

       The following optional sensor block commands provide a way to filter
       the flow	records	that rwflowpack	packs for a sensor.  Each filter
       begins with either discard-when or discard-unless, mentions a flow
       record field, and ends with a list of values.

       The discard-when	command	causes the sensor to ignore the	flow record if
       the property matches any	of the elements	in the list.  When a match is
       found, rwflowpack immediately stops processing the record for the
       current sensor and the flow is not packed for this sensor.

       The discard-unless command causes the sensor to ignore the flow record
       unless the property matches one of the elements in the list.  That is,
       the flow	record is packed only if its property matches one of the
       values specified	in the list, and, when multiple	discard-unless
       commands	are present, if	the flow record	matches	the values specified
       in each.

       For each	individual property, only one of discard-when or discard-
       unless may be specified.

       discard-when source-interfaces interface-list
	   Instructs rwflowpack	to discard a flow record for this sensor if
	   the value in	the flow's "input" field is listed in interface-list.
	   When	paired with VLAN tagging (see the interface-values command in
	   the probe block), this allows the administrator to discard flows
	   that	have a specific	VLAN tag.  The commands	discard-when source-
	   interfaces and discard-unless source-interfaces may not be
	   specified on	the same sensor, but other discard- commands are
	   permitted.

       discard-unless source-interfaces	interface-list
	   Instructs rwflowpack	to discard the flow record for this sensor
	   unless the flow's "input" field is in interface-list.  That is, the
	   flow	record may be packed only if its "input" field matches one of
	   the values specified	in interface-list.  When paired	with VLAN
	   tagging, this allows	one to discard flows that do not have a
	   specific VLAN tag.  The commands discard-when source-interfaces and
	   discard-unless source-interfaces may	not be specified on the	same
	   sensor, but other discard- commands are permitted.

       discard-when destination-interfaces interface-list
	   Discards a flow for this sensor when	the flow's "output" field
	   matches a value in interface-list.  May not appear in the same
	   sensor block	with discard-unless destination-interfaces.

       discard-unless destination-interfaces interface-list
	   Discards a flow for this sensor unless the flow's "output" field
	   matches a value in interface-list.  May not appear in the same
	   sensor block	with discard-when destination-interfaces.

       discard-when any-interfaces interface-list
	   Discards a flow for this sensor when	either the flow's "input" or
	   its "output"	field matches a	value in interface-list.  May not
	   appear in the same sensor block with	discard-unless any-interfaces.

       discard-unless any-interfaces interface-list
	   Discards a flow for this sensor unless either the flow's "input" or
	   its "output"	field matches a	value in interface-list.  May not
	   appear in the same sensor block with	discard-unless any-interfaces.

       discard-when source-ipblocks cidr-block-list
	   Discards a flow for this sensor when	the flow's source IP address,
	   "sIP", matches one of the CIDR blocks in cidr-block-list.  May not
	   appear in the same sensor block with	discard-unless source-
	   ipblocks.

       discard-unless source-ipblocks cidr-block-list
	   Discards a flow for this sensor unless the flow's source IP
	   address, "sIP", matches one of the CIDR blocks in cidr-block-list.
	   May not appear in the same sensor block with	discard-when source-
	   ipblocks.

       discard-when destination-ipblocks cidr-block-list
	   Discards a flow for this sensor when	the flow's destination IP
	   address, "dIP", matches one of the CIDR blocks in cidr-block-list.
	   May not appear in the same sensor block with	discard-unless
	   destination-ipblocks.

       discard-unless destination-ipblocks cidr-block-list
	   Discards a flow for this sensor unless the flow's destination IP
	   address, "dIP", matches one of the CIDR blocks in cidr-block-list.
	   May not appear in the same sensor block with	discard-when
	   destination-ipblocks.

       discard-when any-ipblocks cidr-block-list
	   Discards a flow for this sensor when	either the flow's source IP or
	   its destination IP address matches one of the CIDR blocks in	cidr-
	   block-list.	May not	appear in the same sensor block	with discard-
	   unless any-ipblocks.

       discard-unless any-ipblocks cidr-block-list
	   Discards a flow for this sensor unless either the flow's source IP
	   or its destination IP address matches one of	the CIDR blocks	in
	   cidr-block-list.  May not appear in the same	sensor block with
	   discard-when	any-ipblocks.

       discard-when source-ipsets ipset-list
	   Discards a flow for this sensor when	the flow's source IP address,
	   "sIP", is in	one of IPset files in ipset-list.  May not appear in
	   the same sensor block with discard-unless source-ipsets.  Since
	   SiLK	3.10.0.

       discard-unless source-ipsets ipset-list
	   Discards a flow for this sensor unless the flow's source IP
	   address, "sIP", is in one of	IPset files in ipset-list.  May	not
	   appear in the same sensor block with	discard-when source-ipsets.
	   Since SiLK 3.10.0.

       discard-when destination-ipsets ipset-list
	   Discards a flow for this sensor when	the flow's destination IP
	   address, "dIP", is in one of	the IPset files	in ipset-list.	May
	   not appear in the same sensor block with discard-unless
	   destination-ipsets.	Since SiLK 3.10.0.

       discard-unless destination-ipsets ipset-list
	   Discards a flow for this sensor unless the flow's destination IP
	   address, "dIP", is in one of	the IPset files	in ipset-list.	May
	   not appear in the same sensor block with discard-when destination-
	   ipsets.  Since SiLK 3.10.0.

       discard-when any-ipsets ipset-list
	   Discards a flow for this sensor when	either the flow's source IP or
	   its destination IP address is in one	of the IPset files in ipset-
	   list.  May not appear in the	same sensor block with discard-unless
	   any-ipsets.	Since SiLK 3.10.0.

       discard-unless any-ipsets ipset-list
	   Discards a flow for this sensor unless either the flow's source IP
	   or its destination IP address is in one of the IPset	files in
	   ipset-list.	May not	appear in the same sensor block	with discard-
	   when	any-ipsets.  Since SiLK	3.10.0.

EXAMPLES
       All these examples assume you are using the packlogic-twoway(3) packing
       logic plug-in to	rwflowpack(8).

   Group definitions
       The following shows how to create groups	that can be used in other
       group blocks or in certain commands within a sensor block.

	group G01
	    interfaces 1 2, 3
	    interfaces 4
	end group

	group G02
	    interfaces 5 @G01
	end group

	group G03
	    interfaces @G02
	    interfaces 6
	end group

	group G11
	    ipblocks 192.0.2.0/27  192.0.2.32/27,  192.0.2.64/26
	    ipblocks 192.0.2.128/25
	end group

	group G12
	    ipblocks 198.51.100.0/24  @G11
	end group

	group G13
	    ipblocks @G12
	    ipblocks 203.0.113.0/24
	end group

	group G21
	    ipsets /var/sets/ip1.set  /var/sets/ip2.set,  /var/sets/ip3.set
	    ipsets /var/sets/ip4.set
	end group

	group G22
	    ipsets /var/sets/ip5.set  @G21
	end group

	group G23
	    ipsets @G22
	    ipsets /var/sets/ip6.set
	end group

   NetFlow v5 Categorized by SNMP Interface
       The following two blocks	define a probe that listens on 9900/udp	for
       NetFlow v5 from a router.  The probe only accepts traffic originating
       from 172.16.22.22 or 172.16.33.33.  The associated sensor uses the SNMP
       interfaces to categorize	the flows, where traffic that enters the
       router on interface 1 and leaves	on interface 8 is in, traffic entering
       on 8 and	leaving	on 1 is	out, traffic from 1 to 0 is innull, traffic
       from 8 to 8 is int2int, etc.

	 probe S1 netflow-v5
	     listen-on-port 9901
	     protocol udp
	     accept-from-host 172.16.22.22 172.16.33.33
	 end probe

	 sensor	S1
	     netflow-v5-probes S1
	     external-interfaces 1
	     internal-interfaces 8
	     null-interfaces 0
	 end sensor

   NetFlow v5 Categorized by IP	Address
       The probe in this example is the	same as	above, except the
       administrator has chosen	to log only messages about bad packets
       (messages about missing packets will be ignored).  The sensor is
       categorizing flows by the source	and destination	IP address in the flow
       record.	The internal network is	defined	as 128.2.0.0/16, and all other
       IPs are defined as external.  For example, HTTP traffic whose source is
       128.2.0.1 and destination is google.com will be categorized as outweb;
       the reply (source of google.com and destination 128.2.0.1) will be
       inweb.

	 probe S2 netflow-v5
	     listen-on-port 9902
	     protocol udp
	     accept-from-host 172.16.22.22 172.16.33.33
	     log-flags bad		       # ignore	missing	pkts
	 end probe

	 sensor	S2
	     netflow-v5-probes S2
	     internal-ipblocks 128.2.0.0/16
	     external-ipblocks remainder
	 end sensor

   IPFIX Categorized by	IP Address
       This example uses an IPFIX probe	to collect the flows on	port 9903/tcp,
       where the probe binds to	address	192.168.1.92.  The sensor
       configuration is	the same as in the previous example, but a group
       definition is used to define the	internal network.

	 probe S3 ipfix
	     listen-on-port 9903
	     protocol tcp
	     listen-as-host 192.168.1.92
	 end probe

	 group my-network
	     ipblocks 128.2.0.0/16
	 end group

	 sensor	S3
	     ipfix-probes S3
	     internal-ipblocks @my-network
	     external-ipblocks remainder
	 end sensor

   IPFIX Read from Files
       This example uses the same sensor configuration as above.  The probe
       processes files that have been created by yaf(1)	and stored in the
       directory /tmp/var/yaf/.

	 probe S4 ipfix
	     poll-directory /tmp/var/yaf
	 end probe

	 sensor	S4
	     ipfix-probes S4
	     internal-ipblock 128.2.0.0/16
	     external-ipblock remainder
	 end sensor

   NetFlow v9 Categorized by IP	Address
       This example uses a NetFlow v9 probe to collect the flows on port
       9905/udp, where the probe binds to address 192.168.1.92.	 The sensor
       configuration uses an IPset file	to define the internal network.

	 probe S5 netflow-v9
	     listen-on-port 9905
	     protocol udp
	     listen-as-host 192.168.1.92
	 end probe

	 sensor	S5
	     netflow-v9-probes S5
	     internal-ipsets /var/sets/my-network.set
	     external-ipsets remainder
	 end sensor

   sFlow v5 Categorized	by IP Address
       This example uses an sFlow probe	to collect the flows on	port 9906/udp,
       where the probe binds to	the IPv6 address ::1.  The sensor
       configuration uses an IPset file	to define the internal network.

	 probe S19 sflow
	     listen-on-port 9906
	     protocol udp
	     listen-as-host ::1
	 end probe

	 sensor	S19
	     sflow-probes S19
	     internal-ipsets /var/sets/my-network.set
	     external-ipsets remainder
	 end sensor

   NetFlow v9 from a Cisco ASA Router
       When collecting NetFlow v9 data from a Cisco ASA	(Adaptive Security
       Appliance), specify the quirks statement	as shown in this example to
       enable special handling of the NetFlow data.

	 probe S20 netflow-v9
	     listen-on-port 9988
	     protocol udp
	     quirks firewall-event zero-packets
	 end probe

	 sensor	S20
	     netflow-v9-probes S20
	     internal-ipsets /var/sets/my-network.set
	     external-ipsets remainder
	 end sensor

   Multiple Sources Becoming One Sensor	(One Port)
       Consider	a scenario where there are multiple input streams that need to
       be treated as a single sensor.  For example, you	use multiple routers
       for load-balancing but you want them treated as a single	logical
       sensor.	In this	configuration, you send	all the	input streams to a
       single port, and	you define a single probe listening on that port.  As
       long as the streams have	a unique source	IP, the	streams	will be
       treated distinctly.

       The following sensor and	probe blocks accept any	number of TCP-based
       IPFIX connections to port 9907 and any number of	NetFlow	v5 connections
       to 9908.	 This configuration works for all types	of input as SiLK 3.4.0
       when using libfixbuf-1.2.0.  See	the configuration in the following
       example for a alternate approach.

	 probe S7 ipfix
	     listen-on-port 9907
	     protocol tcp
	 end probe

	 sensor	S7
	     ipfix-probes S7
	     internal-ipblocks 128.2.0.0/16
	     external-ipblocks remainder
	 end sensor

	 probe S8 netflow-v5
	     listen-on-port 9908
	     protocol udp
	     log-flags bad
	 end probe

	 sensor	S8
	     netflow-v5-probes S8
	     internal-ipblocks 128.2.0.0/16
	     external-ipblocks remainder
	 end sensor

   Multiple Sources Becoming One Sensor	(Multiple Ports)
       Like the	previous example, this example configuration causes multiple
       input streams to	be treated as a	single sensor.	In this	solution, each
       stream arrives on a separate port where it is collected by a separate
       probe.  The sensor block	combines the probes into one sensor.  This
       type of approach	works with all types of	input for all releases of
       SiLK.

	 probe S6-p1 netflow-v9
	     listen-on-port 9961
	     protocol udp
	 end probe

	 probe S6-p2 netflow-v9
	     listen-on-port 9962
	     protocol udp
	 end probe

	 probe S6-p3 netflow-v9
	     listen-on-port 9963
	     protocol udp
	 end probe

	 sensor	S6
	     netflow-v9-probes S6-p1, S6-p2, S6-p3
	     internal-ipblocks 128.2.0.0/16
	     external-ipblocks remainder
	 end sensor

   Multiple Sources Becoming One Sensor	(Specific Directions)
       Consider	the case of using yaf on a monitor at the border of a network
       where all traffic entering the network arrives at the monitor on	one
       network interface card (NIC) and	all traffic leaving the	network
       arrives at the monitor on a different NIC.  Since yaf does not support
       multiple	interfaces yet,	you must run two yaf processes,	one for	each
       NIC.  The sensor	configuration for this monitor would list two probes,
       each listening on a different port, and two sensor blocks both packing
       to the same sensor.  Each sensor	block packs the	traffic	as incoming or
       outgoing	depending on which probe received the traffic.

	 probe S9-in ipfix
	     listen-on-port 9991
	     protocol tcp
	 end probe

	 probe S9-out ipfix
	     listen-on-port 9992
	     protocol tcp
	 end probe

	 sensor	S9
	     ipfix-probes S9-in
	     source-network external
	     destination-network internal
	 end sensor

	 sensor	S9
	     ipfix-probes S9-out
	     source-network internal
	     destination-network external
	 end sensor

   Multiple Sources to Multiple	Sensors	(Same Port)
       Suppose your network has	multiple flow generators that you wish to
       treat as	separate sensors, but you would	like to	minimize the number of
       open ports on your firewall.  To	support	this configuration, configure
       the probes to distinguish the traffic based on the source address.
       Specifically, create a separate probe for each sensor where the probes
       of the same type	use the	same listen-on-port value but different
       accept-from-host	values.	 (Different probe types	may not	bind the same
       port; the combination of	listen-on-port,	protocol, and listen-as-host
       must be unique for different probe types.)  The following configuration
       uses a NetFlow v5 probe,	which works for	all versions of	SiLK.  A
       similar configuration works for any type	of input as of SiLK 3.4.0 and
       libfixbuf-1.2.0.

	 probe S10 netflow-v5
	     listen-on-port 9910
	     accept-from-host 172.16.22.10
	     protocol udp
	 end probe

	 probe S11 netflow-v5
	     listen-on-port 9910
	     accept-from-host 172.16.22.11
	     protocol udp
	 end probe

	 group my-network2
	     ipblocks 128.2.0.0/16
	 end group

	 sensor	S10
	     netflow-v5-probes S10
	     internal-ipblocks @my-network2
	     external-ipblocks remainder
	 end sensor

	 sensor	S11
	     netflow-v5-probes S11
	     internal-ipblocks @my-network2
	     external-ipblocks remainder
	 end sensor

   Single Source Becoming Multiple Sensors
       Suppose you have	instrumented a single router but you wish to split the
       traffic into two	sensors, where one part	of the network (monitored by
       sensor S12) is defined as 128.2.0.0/17, and the other (sensor S13) as
       128.2.128.0/17.	Traffic	between	128.2.0.1 and google.com will be
       assigned	to sensor S12, but it will so appear as	ext2ext	traffic	for
       sensor S13 unless you explicitly	discard	that traffic using the
       discard-unless command.

	 probe S12-S13 ipfix
	     listen-on-port 9912
	     protocol tcp
	 end probe

	 group S12-space
	     ipblocks 128.2.0.0/17
	 end group

	 group S13-space
	     ipblocks 128.2.128.0/17
	 end group

	 sensor	S12
	     ipfix-probes S12-S13
	     discard-unless any-ipblock	@S12-space
	     internal-ipblocks @S12-space
	     external-ipblocks remainder
	 end sensor

	 sensor	S13
	     ipfix-probes S12-S13
	     discard-unless any-ipblock	@S13-space
	     internal-ipblocks @S13-space
	     external-ipblocks remainder
	 end sensor

   Discarding Flows Using VLAN Tags
       You can configure rwflowpack to discard flows that do not have a
       particular VLAN tag.  First, specify the	interface-values command to
       instruct	the probe to put the VLAN id into the fields that typically
       store the SNMP interfaces.  On the sensor, use the discard-unless
       command to discard flows	that do	not have the desired VLAN tag (114 in
       this example).  Often you will not use the VLAN tags to determine a
       flow's direction	(category) since there is a single VLAN	tag on each
       flow; instead, you specify the IP space of the monitored	network	in the
       sensor block.  (However,	see the	next example.)

	 probe S14 ipfix
	     listen-on-port 9914
	     protocol tcp
	     interface-values vlan
	 end probe

	 sensor	S14
	     ipfix-probes S14
	     discard-unless any-interface 114
	     internal-ipblocks 128.2.0.0/16
	     external-ipblocks remainder
	 end sensor

   Categorizing	Flows Using VLAN Tags
       By repeating a sensor block and using different discard-unless commands
       in each block, you may configure	rwflowpack to categorize flow records
       based on	VLAN tags.  Suppose yaf	is monitoring a	connection where
       incoming	flows are marked with VLAN tag 151 and outgoing	flows are
       marked with 152.	 You simply discard any	traffic	that does not have the
       wanted VLAN tag,	and use	the source-network and destination-network
       commands	to assign the direction	to the flow.  In this example, any
       flow record that	does not have one of the expected VLAN tags has	its
       source-network set to "null", but since rwflowpack does not expect a
       flow record to originate	from the null network, it stores the record in
       the other category for later analysis/debugging.	 (This example
       requires	SiLK 3.1 or later.)

	 probe S15 ipfix
	     listen-on-port 9915
	     protocol tcp
	     interface-values vlan
	 end probe

	 sensor	S15
	     # vlan ID 151 is incoming
	     ipfix-probes S15
	     discard-unless source-interface 151
	     source-network	  external
	     destination-network  internal
	 end sensor

	 sensor	S15
	     # vlan ID 152 is outgoing
	     ipfix-probes S15
	     discard-unless source-interface 152
	     source-network	  internal
	     destination-network  external
	 end sensor

	 sensor	S15
	     # discard flows that have known IDs
	     # force unknown IDs into the "other" category
	     ipfix-probes S15
	     discard-when source-interface 151,152
	     source-network	  null
	     destination-network  internal
	 end sensor

   IPFIX Collected by a	DAG Card
       When yaf	generates flow records from a multi-port Endace	DAG card, it
       is possible to use the port where the traffic was seen to categorize
       the traffic in rwflowpack.

       To do this, include the --dag-interface switch on the yaf command line.
       This switch causes yaf to store the DAG port where the packet was
       collected into the equivalent of	the SNMP input field, and yaf sets the
       SNMP output field to an offset of the port, specifically	the port plus
       256 (0x100|port).

       Assume DAG port 0 is connected to the external side of the network (so
       it sees incoming	traffic), and assume DAG port 1	is on the internal
       side.  For incoming traffic, yaf	sets the input and output values to 0
       and 256,	respectively.  For outgoing traffic, the values	are 1 and 257.

       The sensor.conf configuration file for rwflowpack would be:

	 probe S16-dag ipfix
	     listen-on-port 9916
	     protocol tcp
	 end probe

	 sensor	S16
	     ipfix-probes S16-dag
	     external-interface	0,257
	     internal-interface	1,256
	 end sensor

       When rwflowpack processes the IPFIX flow	records, it treats flow
       records having an input of 0 and	an output of 256 as traffic moving
       from an external	interface to an	internal interface, and	rwflowpack
       packs those records as incoming.	 Similarly for the outgoing flow
       records.

   Repacking of	SiLK Flows by IP Address
       A probe whose type is "silk" must get its flows by polling a directory
       of SiLK Flow files.  The	flows can be re-categorized based on the IP
       addresses or based on the SNMP interfaces (beware: often	the SNMP
       interface values	are 0 in SiLK Flow data).  In this example, the	files
       in the directory	/var/tmp/old-data/ are processed.  The internal
       network is defined as 128.2.0.0/16, and all other IPs are defined as
       external.

	 probe S17 silk
	     poll-directory /var/tmp/old-data
	 end probe

	 sensor	S17
	     silk-probes S17
	     internal-ipblock 128.2.0.0/16
	     external-ipblock remainder
	 end sensor

   NetFlow From	a File Categorized by SNMP Interfaces
       Instead of listening on a UDP port for NetFlow traffic, you can
       configure the probe to process a	single file containing NetFlow v5
       PDUs.  This example assumes you are running rwflowpack with the
       switches	--input-mode=file --netflow-file=FILENAME.  The	--netflow-file
       switch overrides	the read-from-file command on the probe.  rwflowpack
       will exit once it processes that	single file.

	 probe S18 netflow-v5
	     log-flags bad		       # ignore	missing	pkts
	     read-from-file /dev/null	       # use --netflow-file=<file>
	 end probe

	 sensor	S18
	     netflow-v5-probes S18
	     external-interface	182
	     internal-interface	189
	     null-interface 0
	 end sensor

SEE ALSO
       rwflowpack(8), flowcap(8), packlogic-twoway(3), packlogic-generic(3),
       rwsetbuild(1), silk.conf(5), silk(7), SiLK Installation Handbook,
       pcap(3),	yaf(1),	gzip(1)

NOTES
       Support for using double-quoted strings for IPset path names was	added
       in SiLK 3.17.2.

       The accept-from-host command began to accept a list of arguments	in
       SiLK 3.10.1.

       SiLK 3.10.0 added IPset file support to the group block and to some
       commands	in the sensor block.

       Support for collecting sFlow records was	added in SiLK 3.9.0.

       The quirks command was introduced in SiLK 3.8.0.

SiLK 3.19.1			  2021-02-28			sensor.conf(5)

NAME | DESCRIPTION | SYNTAX | EXAMPLES | SEE ALSO | NOTES

Want to link to this manual page? Use this URL:
<https://www.freebsd.org/cgi/man.cgi?query=sensor.conf&sektion=5&manpath=FreeBSD+13.0-RELEASE+and+Ports>

home | help