sane-genesys(5)		 SANE Scanner Access Now Easy	       sane-genesys(5)

NAME
       sane-genesys  -	SANE  backend for GL646, GL841,	GL843, GL847 and GL124
       based USB flatbed scanners

DESCRIPTION
       The sane-genesys	library	implements a SANE (Scanner  Access  Now	 Easy)
       backend	that  provides	access	to  USB	 flatbed scanners based	on the
       Genesys GL646, GL841, GL843, GL847 and GL124 chips.   At	 present,  the
       following scanners are known to work with this backend:

	      Canon LiDE 35/40/50/60/100/110/200/210/220/700
	      Hewlett-Packard HP2300C/HP2400/HP3670/HP3690/G4010/G4050
	      Medion MD5345/MD6228/MD6274
	      Panasonic	KV-SS080
	      Plustek OpticBook	3600
	      Pentax DSmobile 600
	      Syscan/Ambir DocketPORT 467/485/487/665/685
	      Visioneer	OneTouch 7100/Strobe XP100 (rev3)/XP200/XP300/Roadwar-
	      rior
	      Xerox Travel Scanner 100,	OneTouch 2400

       This is stable software for supported models. But if you	 test  new  or
       untested	 scanners, keep	your hand at the scanner's plug	and unplug it,
       if the head bumps at the	end of the scan	area.

       If you own a scanner other than the ones	listed above that  works  with
       this  backend,  please  let me know this	by sending the scanner's exact
       model  name  and	 the  USB   vendor   and   device   ids	  (e.g.	  from
       /proc/bus/usb/devices,  sane-find-scanner  or syslog) to	the sane-devel
       mailing list. Even if the scanner's name	 is  only  slightly  different
       from the	models mentioned above,	please let me know.

       If you own a scanner that isn't detected	by the genesys backend but has
       a GL646,	GL841, GL843, GL847 or GL124 chipset, you can try to add it to
       the backend.

CALIBRATION
       To give correct image quality, sheet fed	scanners need to be calibrated
       using the calibration sheet sold	with the scanner. To  do  calibration,
       you must	insert this target in the feeder then start calibration	either
       by passing the --calibrate option to scanimage or by  clicking  on  the
       available  'calibrate'  button in the 'advanced options'	in a graphical
       frontend. The result of the calibration is stored in a file in the home
       directory of the	user doing it.	If you plug the	scanner	in another ma-
       chine or	use it with another account, calibration will have to  be  re-
       done,  unles  you use the --calibration-file option.  If	no home	direc-
       tory is defined,	USERAPPPROFILE will be used, then TMPDIR  or  TMP.  If
       none  of	 these directories exist, the backend will try to write	in the
       current working directory. Flatbed scanners also	make use of the	 cali-
       bration file as a cache to avoid	calibration before each	scan. Calibra-
       tion file name is the name of the scanner model if only one scanner  is
       detected. In the	case of	several	identical model, the file name will be
       the name	of the logical USB device name.	The  expiration	 time  manages
       the time	a calibration is valid in cache.  A value of -1	means forever,
       0 means no cache.

EXTRAS SCAN OPTIONS
       --lamp-off-time number
		      The lamp will be turned off after	 the  given  time  (in
	      minutes).	A value	of 0 means that	the lamp won't be turned off.

       --threshold percent
		   0..100% (in steps of	1). Select minimum brightness to get a
	      white point. Pixels whith	brightness below that  value  will  be
	      scanned as black.

       --brightness value
		   -100..100  (in steps	of 1). Set the brightness enhancement.
	      0	for no enhancement, negative values  to	 decrease  brigthness,
	      and positive values to increase it.

       --contrast value
		   -100..100  (in steps	of 1). Set the contrast	enhancement. 0
	      for no enhancement, negative values to  decrease	contrast,  and
	      positive values to increase it.

       --disable-interpolation yes|no
		      When using high resolutions where	the horizontal resolu-
	      tion is smaller than vertical resolution,	data  is  expanded  by
	      software	to  preserve picture geometry. This can	be disabled by
	      this option to get real scanned data.

       --disable-dynamic-lineart yes|no
		      Disable use of a software	adaptive algorithm to generate
	      lineart and rely on hardware lineart.

       --color-filter None|Red|Green|Blue
		      When  using gray or lineart this option selects the used
	      color. Using a color filter will give  a	monochrome  scan.  CIS
	      based  scanners  can to true gray	when no	filter (None value) is
	      selected.

       --lamp-off-scan
		      The lamp will be turned off during the scan. Calibration
	      is still done with lamp on.

       --clear-calibration
		      Clear  calibration cache data, triggering	a new calibra-
	      tion for the device when the next	scan will happen.

       --calibration-file
		      Specify the calibration file name	to use.	At  least  the
	      directory	containing the file must exist,	since it won't be cre-
	      ated. This option	is disabled if the backend is ran as root.  It
	      maybe  used in case of sheet-fed scanners	to share a calibration
	      file for several users.

       --expiration-time
		      Specify the time (in minutes) a  cached  calibration  is
	      considered  valid. If older than the given value,	a new calibra-
	      tion is done. A value of -1 means	no expiration and cached value
	      are  kept	 forever  unless  cleared  by userwith the calibration
	      clear option. A value of 0 means cache is	disabled.

       Additionally, several 'software'	options	are exposed  by	 the  backend.
       These  are  reimplementations  of  features provided natively by	larger
       scanners, but running on	the host computer. This	 enables  smaller  ma-
       chines  to  have	 similar capabilities. Please note that	these features
       are somewhat simplistic,	and may	not perform as well as the native  im-
       plementations.  Note  also  that	 these	features  all require that the
       driver cache the	entire image in	memory.	This will almost certainly re-
       sult in a reduction of scanning speed.

       --swcrop
		   Requests  the driver	to detect the extremities of the paper
	      within the larger	image, and crop	the empty edges.

       --swdeskew
		   Requests the	driver to detect the  rotation	of  the	 paper
	      within the larger	image, and counter the rotation.

       --swdespeck --despeck X
		   Requests  the  driver to find and remove dots of X diameter
	      or smaller from the image, and fill the space with  the  average
	      surrounding color.

       --swskip	0..100%	(in steps of 1)	[0]
		      Request driver to	discard	pages with low numbers of dark
	      pixels.

       --swderotate[=(yes|no)] [no]
		      Request driver to	detect and correct 90 degree image ro-
	      tation.

SYSTEM ISSUES
       This  backend  needs libusb-0.1.6 or later installed, and hasn't	tested
       in other	configuration than a linux kernel 2.6.9	or higher. However, it
       should  work  any system	with libusb where the SANE package can be com-
       piled. For setting permissions and  general  USB	 information  look  at
       sane-usb(5).

CONFIGURATION
       The contents of the genesys.conf	file is	a list of usb lines containing
       vendor and product ids that correspond to USB scanners.	The  file  can
       also  contain option lines.  Empty lines	and lines starting with	a hash
       mark (#)	are ignored.  The scanners are autodetected by	usb  vendor_id
       product_id  statements  which  are  already included into genesys.conf.
       "vendor_id" and "product_id" are	hexadecimal numbers that identify  the
       scanner.

FILES
       /usr/local/etc/sane.d/genesys.conf
	      The   backend   configuration  file  (see	 also  description  of
	      SANE_CONFIG_DIR below).

       /usr/local/lib/sane/libsane-genesys.a
	      The static library implementing this backend.

       /usr/local/lib/sane/libsane-genesys.so
	      The shared library implementing this backend (present on systems
	      that support dynamic loading).

ENVIRONMENT
       SANE_CONFIG_DIR
	      This environment variable	specifies the list of directories that
	      may contain the configuration file.  Under UNIX, the directories
	      are  separated  by a colon (`:'),	under OS/2, they are separated
	      by a semi-colon (`;').  If this variable is not set, the config-
	      uration  file is searched	in two default directories: first, the
	      current  working	directory   (".")   and	  then	 in   /usr/lo-
	      cal/etc/sane.d.	If  the	value of the environment variable ends
	      with the directory separator character, then the default	direc-
	      tories  are searched after the explicitly	specified directories.
	      For example, setting SANE_CONFIG_DIR to "/tmp/config:" would re-
	      sult   in	  directories	"tmp/config",	".",   and   "/usr/lo-
	      cal/etc/sane.d" being searched (in this order).

       SANE_DEBUG_GENESYS
	      If the library was compiled with debug support enabled, this en-
	      vironment	 variable  controls  the debug level for this backend.
	      Higher debug levels increase the verbosity of the	output.	If the
	      debug  level  is	set  to	1 or higher, some debug	options	become
	      available	that are normally hidden. Handle them with care.  This
	      will print messages related to core genesys functions.

       SANE_DEBUG_GENESYS_LOW
	      This environment variable	controls the debug level for low level
	      functions	common to all genesys ASICs.

       SANE_DEBUG_GENESYS_GL646
	      This environment variable	controls the debug level for the  spe-
	      cific GL646 code part.

       SANE_DEBUG_GENESYS_GL841
	      This  environment	variable controls the debug level for the spe-
	      cific GL841 code part.

       SANE_DEBUG_GENESYS_GL843
	      This environment variable	controls the debug level for the  spe-
	      cific GL843 code part.

       SANE_DEBUG_GENESYS_GL847
	      This  environment	variable controls the debug level for the spe-
	      cific GL847 code part.

       SANE_DEBUG_GENESYS_GL124
	      This environment variable	controls the debug level for the  spe-
	      cific GL124 code part.

	      Example (full and	highly verbose output for gl646):
	      export SANE_DEBUG_GENESYS=255
	      export SANE_DEBUG_GENESYS_LOW=255
	      export SANE_DEBUG_GENESYS_GL646=255

CREDITS
       Jack  McGill  for donating several sheetfed and flatbed scanners, which
       made possible to	add support for	them in	the genesys backend:
	      Hewlett-Packard HP3670
	      Visioneer	Strobe XP100 (rev3)/XP200/XP300/Roadwarrior
	      Canon LiDE 200
	      Pentax DSmobile 600
	      Syscan/Ambir DocketPORT 467/485/487/665/685
	      Xerox Travel Scanner 100,	Onetouch 2400

       cncsolutions (http://www.cncsolutions.com.br) sponsored	and  supported
       the work	on the Panasonic KV-SS080.

       Brian  Paavo  from Benthic Science Limited for donating a Canoscan LiDE
       700F.

       Dany Qumsiyeh for donating a Canoscan LiDE 210 and a LiDE 220.

SEE ALSO
       sane(7),	sane-usb(5)

AUTHOR
       Oliver Rauch
       Henning Meier-Geinitz <henning@meier-geinitz.de>
       Gerhard Jaeger <gerhard@gjaeger.de>
       Stephane	Voltz <stef.dev@free.fr>
       Philipp Schmid <philipp8288@web.de>
       Pierre Willenbrock <pierre@pirsoft.dnsalias.org>
       Alexey Osipov <simba@lerlan.ru> for HP2400 final	support

LIMITATIONS
       Powersaving isn't implemented for gl646 based  scanner.	Dynamic	 (emu-
       lated  from gray	data and with dithering) isn't enabled for gl646 scan-
       ners. Hardware lineart is limited up to 600 dpi for gl847  based	 scan-
       ners, due to the	way image sensors are built.

       This  backend  will  be much slower if not using	libusb-1.0. So be sure
       that sane-backends is built with	the --enable-libusb_1_0	option.

BUGS
       For the LiDE 200, the scanned data at 4800 dpi is obtained "as is" from
       sensor. It seems	the windows driver does	some digital processing	to im-
       prove it, which is not implemented in the backend.

				  4 Jul	2012		       sane-genesys(5)