MODBUS_SET_SLAVE(3)	       libmodbus Manual		   MODBUS_SET_SLAVE(3)

NAME
       modbus_set_slave	- set slave number in the context

SYNOPSIS
       int modbus_set_slave(modbus_t *ctx, int slave);

DESCRIPTION
       The modbus_set_slave() function shall set the slave number in the
       libmodbus context.

       The behavior depends of network and the role of the device:

       RTU
	   Define the slave ID of the remote device to talk in master mode or
	   set the internal slave ID in	slave mode. According to the protocol,
	   a Modbus device must	only accept message holding its	slave number
	   or the special broadcast number.

       TCP
	   The slave number is only required in	TCP if the message must	reach
	   a device on a serial	network. Some not compliant devices or
	   software (such as modpoll) uses the slave ID	as unit	identifier,
	   that's incorrect (cf	page 23	of Modbus Messaging Implementation
	   Guide v1.0b)	but without the	slave value, the faulty	remote device
	   or software drops the requests! The special value MODBUS_TCP_SLAVE
	   (0xFF) can be used in TCP mode to restore the default value.

       The broadcast address is	MODBUS_BROADCAST_ADDRESS. This special value
       must be use when	you want all Modbus devices of the network receive the
       request.

RETURN VALUE
       The function shall return 0 if successful. Otherwise it shall return -1
       and set errno to	one of the values defined below.

ERRORS
       EINVAL
	   The slave number is invalid.

EXAMPLE
	   modbus_t *ctx;

	   ctx = modbus_new_rtu("/dev/ttyUSB0",	115200,	'N', 8,	1);
	   if (ctx == NULL) {
	       fprintf(stderr, "Unable to create the libmodbus context\n");
	       return -1;
	   }

	   rc =	modbus_set_slave(ctx, YOUR_DEVICE_ID);
	   if (rc == -1) {
	       fprintf(stderr, "Invalid	slave ID\n");
	       modbus_free(ctx);
	       return -1;
	   }

	   if (modbus_connect(ctx) == -1) {
	       fprintf(stderr, "Connection failed: %s\n", modbus_strerror(errno));
	       modbus_free(ctx);
	       return -1;
	   }

SEE ALSO
       modbus_get_slave(3)

AUTHORS
       The libmodbus documentation was written by StA(C)phane Raimbault
       <stephane.raimbault@gmail.com>

libmodbus v3.1.6		  03/01/2021		   MODBUS_SET_SLAVE(3)