MODBUS_READ_INPUT_RE(3) libmodbus Manual MODBUS_READ_INPUT_RE(3) NAME modbus_read_input_registers - read many input registers SYNOPSIS int modbus_read_input_registers(modbus_t *ctx, int addr, int nb, uint16_t *dest); DESCRIPTION The modbus_read_input_registers() function shall read the content of the nb input registers to address addr of the remote device. The result of the reading is stored in dest array as word values (16 bits). You must take care to allocate enough memory to store the results in dest (at least nb * sizeof(uint16_t)). The function uses the Modbus function code 0x04 (read input registers). The holding registers and input registers have different historical meaning, but nowadays it's more common to use holding registers only. RETURN VALUE The function shall return the number of read input registers if successful. Otherwise it shall return -1 and set errno. ERRORS EMBMDATA Too many bits requested SEE ALSO modbus_read_input_bits(3) modbus_write_register(3) modbus_write_registers(3) AUTHORS The libmodbus documentation was written by StA(C)phane Raimbault <stephane.raimbault@gmail.com> libmodbus v3.1.6 08/10/2020 MODBUS_READ_INPUT_RE(3)