ipmiseld.conf(5)		 ipmiseld.conf		      ipmiseld.conf(5)

NAME
       ipmiseld.conf - ipmiseld	configuration file

DESCRIPTION
       The ipmiseld configuration file configures the ipmiseld daemon.

       The  default  configuration  file loaded	is /usr/local/etc/freeipmi/ip-
       miseld.conf.

       The configuration options that can be specified	in  the	 configuration
       file  are  listed  below. Each configuration option must	be listed on a
       separate	line. Arguments	for an option are separated by any  amount  of
       whitespace.  Multiple arguments are also	separated by whitespace.  Com-
       ments can be marked by using the	pound sign ("#") character, and	 lines
       can be continued	on the next using backslash ("\").

       Note  that  it is possible to list the username,	password and other po-
       tentially sensitive information in the configuration file. If this data
       is  stored  in a	configuration file, system administrators should limit
       access to this file.

IPMISELD CONFIGURATION OPTIONS
       driver-type IPMIDRIVER
	      Specify the driver type to use.

       disable-auto-probe ENABLE|DISABLE
	      Specify if IPMI devices should be	probed for settings.

       driver-address DRIVER-ADDRESS
	      Specify the in-band driver address to use.

       driver-device DEVICE
	      Specify the in-band driver device	path to	use.

       register-spacing	REGISTER-SPACING
	      Specify the in-band driver register spacing to use.

       target-channel-number CHANNEL-NUMBER
	      Specify the in-band driver target	channel	number.

       target-slave-address SLAVE-ADDRESS
	      Specify the in-band driver target	slave address.

       hostname	IPMIHOST1,IPMIHOST2,...
	      Specify the remote host(s) to communicate	with.  Multiple	 host-
	      names  may  be separated by comma	or may be specified in a range
	      format.

       username	USERNAME
	      Specify the username to use.

       password	PASSWORD
	      Specify the password to use.

       k_g str
	      Specify the BMC key (K_g)	to use.	Prefix with '0x' to enter  the
	      key in hex.

       session-timeout MILLISECONDS
	      Specify the session timeout length to use	in milliseconds.

       retransmission-timeout MILLISECONDS
	      Specify  the  retransmission  timeout length to use in millisec-
	      onds.

       authentication-type AUTHENTICATION-TYPE
	      Specify the authentication type to use. The following  authenti-
	      cation  types  are  supported: NONE, STRAIGHT_PASSWORD_KEY, MD2,
	      and MD5.

       cipher-suite-id CIPHER-SUITE-ID
	      Specify the cipher suite id to use. The following	 cipher	 suite
	      ids are supported: 0, 1, 2, 3, 6,	7, 8, 11, 12.

       privilege-level PRIVILEGE-LEVEL
	      Specify  the privilege type to use. The following	privilege lev-
	      els are supported: USER, OPERATOR, ADMIN.

       workaround-flags	WORKAROUNDS
	      Specify workaround flags to use.	Multiple  workarounds  can  be
	      specified	 separated by whitespace. Please see tool manpages for
	      details about available workarounds for each tool. The following
	      workarounds  are	supported:  assumeio,  spinpoll,  idzero, for-
	      cepermsg,	unexpectedauth,	endianseq, authcap, intel20,  supermi-
	      cro20,  sun20,  opensesspriv,  integritycheckvalue, assumesyste-
	      mevent.

       verbose-count COUNT
	      Specify default verbose count to use for ipmi-sel(8).

       sensors-types TYPE-LIST
	      Specify sensor types of SEL events to log. Multiple types	can be
	      specified	 separated  by	whitespace.  Users  may	specify	sensor
	      types by string or by number (decimal or hex). Please see	 ipmi-
	      sel(8) --list-types option to see	possible string	input types.

       exclude-sensor-types ENSOR-TYPES-LIST
	      Specify  sensor  types  of SEL events to not log.	default	sensor
	      types to not show	sensor outputs for. Multiple sensor types  can
	      be  specified  separated by whitespace. Users may	specify	sensor
	      types  by	 string	 or  by	  number.   Please   see   ipmi-sel(8)
	      --list-types option to see possible string input types.

       system-event-only ENABLE|DISABLE
	      Specify if output	should only include system event records.

       oem-event-only ENABLE|DISABLE
	      Specify if output	should only include OEM	event records.

       event-state-config-file FILE
	      Specify the event	state configuration file.

       interpret-oem-data ENABLE|DISABLE
	      Specify if ipmiseld should attempt to interpret OEM data or not.

       entity-sensor-names ENABLE|DISABLE
	      Specify  if output of sensor names should	include	entity ids and
	      instances	or not.

       non-abbreviated-units ENABLE|DISABLE
	      Specify if output	should have units abbreviated  by  default  or
	      not.

       event-state-filter FILTERSTRING
	      Specify event states to be filtered out and not logged.

       --warning-threshold PERCENTINT
	      Specify SEL fullness warning threshold as	an integer percentage.

       --clear-threshold PERCENTINT
	      Specify SEL fullness clear threshold as an integer percentage.

       system-event-format FORMATSTRING
	      Specify  the format of the log output when a SEL system event is
	      encountered.

       oem-timestamped-event-format FORMATSTRING
	      Specify the format of the	log output when	a SEL OEM  timestamped
	      event is encountered.

       oem-non-timestamped-event-format	FORMATSTRING
	      Specify  the  format of the log output when a SEL	OEM non-times-
	      tamped event is encountered.

       poll-interval SECONDS
	      Specify the poll interval	to check the SEL for new events.

       log-facility STRING
	      Specify the log facility to use.

       log-priority STRING
	      Specify the log priority to use.

       cache-directory DIRECTORY
	      Specify the cache	directory to use.

       ignore-sdr DISABLE
	      Specify if the SDR should	be ignored.

       re-download-sdr DISABLE
	      Specify if the SDR should	be re-downloaded on start.

       clear-sel DISABLE
	      Specify if the SEL should	be cleared on start.

       threadpool-count	NUM
	      Specify the threadpool count for parallel	SEL polling.

FILES
       /usr/local/etc/freeipmi/ipmiseld.conf

REPORTING BUGS
       Report bugs to <freeipmi-users@gnu.org> or <freeipmi-devel@gnu.org>.

COPYRIGHT
       Copyright (C) 2012-2015 Lawrence	Livermore National Security, LLC.

SEE ALSO
       ipmiseld(8), ipmi-sel(8)

       http://www.gnu.org/software/freeipmi/

ipmiseld.conf 1.6.5		  2020-05-21		      ipmiseld.conf(5)