ipmi-config.conf(5)		System Commands		   ipmi-config.conf(5)

NAME
       ipmi-config - IPMI configuration	file details

DESCRIPTION
       Before  many  IPMI  tools can be	used over a network, a machine's Base-
       board Management	Controller (BMC) must be configured. The configuration
       can  be	quite daunting for those who do	not know much about IPMI. This
       manpage hopes to	provide	enough information  on	BMC  configuration  so
       that you	can configure the BMC for your system. When appropriate, typi-
       cal BMC configurations will be suggested.

       The following is	an example configuration file partially	 generated  by
       running	the  --checkout	 option	 with the ipmi-config(8) command. This
       configuration comes from	the core category of configuration values (the
       default).  This	example	 configuration	should	be sufficient for most
       users after the appropriate local IP and	MAC addresses are input.  Fol-
       lowing this example, separate sections of this manpage will discuss the
       different sections of the configuration file in more detail with	expla-
       nations of how the BMC can be configured	for different environments.

       Note  that  many	options	may or may not be available on your particular
       machine.	For example, Serial-Over-Lan (SOL) is available	only  on  IPMI
       2.0  machines.  Therefore,  if you are looking to configure an IPMI 1.5
       machine,	many of	the SOL	or IPMI	2.0 related options  will  be  be  un-
       available  to  you.  The	number of configurable users may also vary for
       your particular machine.

       The below configuration file and	most of	this manpage assume  the  user
       is interested in	configuring a BMC for use with IPMI over LAN.  Various
       configuration options from ipmi-config(8) have been left	out or skipped
       because	it is considered unnecessary.  Future versions of this manpage
       will try	to include more	information.

	    Section User1
	     ##	Give username
	     ##	Username NULL
	     ##	Give password or leave it blank	to clear password
	     Password mypassword
	     ##	Possible values: Yes/No	or blank to not	set
	     Enable_User Yes
	     ##	Possible values: Yes/No
	     Lan_Enable_Ipmi_Msgs Yes
	     ##	Possible values: Callback/User/Operator/Administrator/OEM_Proprietary/No_Access
	     Lan_Privilege_Limit Administrator
	       ## Possible values: 0-17, 0 is unlimited; May be	reset to 0 if not specified
	       ## Lan_Session_Limit
	     ##	Possible values: Yes/No
	     SOL_Payload_Access	Yes
	    EndSection
	    Section User2
	     ##	Give username
	     Username user2
	     ##	Give password or leave it blank	to clear password
	     Password userpass
	     ##	Possible values: Yes/No	or blank to not	set
	     Enable_User No
	     ##	Possible values: Yes/No
	     Lan_Enable_Ipmi_Msgs No
	     ##	Possible values: Callback/User/Operator/Administrator/OEM_Proprietary/No_Access
	     Lan_Privilege_Limit No_Access
	       ## Possible values: 0-17, 0 is unlimited; May be	reset to 0 if not specified
	       ## Lan_Session_Limit
	       ## Possible values: Yes/No
	       SOL_Payload_Access No
	    EndSection
	    Section Lan_Channel
	     ##	Possible values: Disabled/Pre_Boot_Only/Always_Available/Shared
	     Volatile_Access_Mode Always_Available
	     ##	Possible values: Yes/No
	     Volatile_Enable_User_Level_Auth Yes
	     ##	Possible values: Yes/No
	     Volatile_Enable_Per_Message_Auth Yes
	     ##	Possible values: Yes/No
	     Volatile_Enable_Pef_Alerting No
	     ##	Possible values: Callback/User/Operator/Administrator/OEM_Proprietary/No_Access
	     Volatile_Channel_Privilege_Limit Administrator
	     ##	Possible values: Disabled/Pre_Boot_Only/Always_Available/Shared
	     Non_Volatile_Access_Mode Always_Available
	     ##	Possible values: Yes/No
	     Non_Volatile_Enable_User_Level_Auth Yes
	     ##	Possible values: Yes/No
	     Non_Volatile_Enable_Per_Message_Auth Yes
	     ##	Possible values: Yes/No
	     Non_Volatile_Enable_Pef_Alerting No
	     ##	Possible values: Callback/User/Operator/Administrator/OEM_Proprietary/No_Access
	     Non_Volatile_Channel_Privilege_Limit Administrator
	    EndSection
	    Section Lan_Conf
	     ##	Possible values: Unspecified/Static/Use_DHCP/Use_BIOS/Use_Others
	     Ip_Address_Source Static
	     ##	Give valid IP Address
	     Ip_Address	192.168.1.100
	     ##	Give valid MAC Address
	     Mac_Address 00:0E:0E:FF:AA:12
	     ##	Give valid Subnet mask
	     Subnet_Mask 255.255.255.0
	     ##	Give valid IP Address
	     Default_Gateway_Ip_Address	192.168.1.1
	     ##	Give valid MAC Address
	     Default_Gateway_Mac_Address 00:0E:0E:FF:AA:18
	     ##	Give valid IP Address
	     Backup_Gateway_Ip_Address 192.168.1.2
	     ##	Give valid MAC Address
	     Backup_Gateway_Mac_Address	00:0E:0E:FF:AA:15
	    EndSection
	    Section Lan_Conf_Auth
	     ##	Possible values: Yes/No
	     Callback_Enable_Auth_Type_None No
	     ##	Possible values: Yes/No
	     Callback_Enable_Auth_Type_Md2 No
	     ##	Possible values: Yes/No
	     Callback_Enable_Auth_Type_Md5 No
	     ##	Possible values: Yes/No
	     Callback_Enable_Auth_Type_Straight_Password No
	     ##	Possible values: Yes/No
	     Callback_Enable_Auth_Type_Oem_Proprietary No
	     ##	Possible values: Yes/No
	     User_Enable_Auth_Type_None	No
	     ##	Possible values: Yes/No
	     User_Enable_Auth_Type_Md2 Yes
	     ##	Possible values: Yes/No
	     User_Enable_Auth_Type_Md5 Yes
	     ##	Possible values: Yes/No
	     User_Enable_Auth_Type_Straight_Password No
	     ##	Possible values: Yes/No
	     User_Enable_Auth_Type_Oem_Proprietary No
	     ##	Possible values: Yes/No
	     Operator_Enable_Auth_Type_None No
	     ##	Possible values: Yes/No
	     Operator_Enable_Auth_Type_Md2 Yes
	     ##	Possible values: Yes/No
	     Operator_Enable_Auth_Type_Md5 Yes
	     ##	Possible values: Yes/No
	     Operator_Enable_Auth_Type_Straight_Password No
	     ##	Possible values: Yes/No
	     Operator_Enable_Auth_Type_Oem_Proprietary No
	     ##	Possible values: Yes/No
	     Admin_Enable_Auth_Type_None No
	     ##	Possible values: Yes/No
	     Admin_Enable_Auth_Type_Md2	Yes
	     ##	Possible values: Yes/No
	     Admin_Enable_Auth_Type_Md5	Yes
	     ##	Possible values: Yes/No
	     Admin_Enable_Auth_Type_Straight_Password No
	     ##	Possible values: Yes/No
	     Admin_Enable_Auth_Type_Oem_Proprietary No
	     ##	Possible values: Yes/No
	     Oem_Enable_Auth_Type_None No
	     ##	Possible values: Yes/No
	     Oem_Enable_Auth_Type_Md2 No
	     ##	Possible values: Yes/No
	     Oem_Enable_Auth_Type_Md5 No
	     ##	Possible values: Yes/No
	     Oem_Enable_Auth_Type_Straight_Password No
	     ##	Possible values: Yes/No
	     Oem_Enable_Auth_Type_Oem_Proprietary No
	    EndSection
	    Section Lan_Conf_Security_Keys
	       ## Give string or blank to clear. Max 20	chars
	       K_G
	    EndSection
	    Section Lan_Conf_Misc
	     ##	Possible values: Yes/No
	     Enable_Gratuitous_Arps Yes
	     ##	Possible values: Yes/No
	     Enable_Arp_Response No
	     ##	Give valid number. Intervals are 500 ms.
	     Gratuitous_Arp_Interval 4
	    EndSection
	    Section Rmcpplus_Conf_Privilege
	     ##	Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
	     Maximum_Privilege_Cipher_Suite_Id_0 Unused
	     ##	Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
	     Maximum_Privilege_Cipher_Suite_Id_1 Unused
	     ##	Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
	     Maximum_Privilege_Cipher_Suite_Id_2 Unused
	     ##	Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
	     Maximum_Privilege_Cipher_Suite_Id_3 Administrator
	     ##	Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
	     Maximum_Privilege_Cipher_Suite_Id_4 Administrator
	     ##	Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
	     Maximum_Privilege_Cipher_Suite_Id_5 Administrator
	     ##	Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
	     Maximum_Privilege_Cipher_Suite_Id_6 Unused
	     ##	Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
	     Maximum_Privilege_Cipher_Suite_Id_7 Unused
	     ##	Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
	     Maximum_Privilege_Cipher_Suite_Id_8 Administrator
	     ##	Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
	     Maximum_Privilege_Cipher_Suite_Id_9 Administrator
	     ##	Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
	     Maximum_Privilege_Cipher_Suite_Id_10 Administrator
	     ##	Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
	     Maximum_Privilege_Cipher_Suite_Id_11 Unused
	     ##	Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
	     Maximum_Privilege_Cipher_Suite_Id_12 Administrator
	     ##	Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
	     Maximum_Privilege_Cipher_Suite_Id_13 Administrator
	     ##	Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
	     Maximum_Privilege_Cipher_Suite_Id_14 Administrator
	    EndSection
	    Section SOL_Conf
	     ##	Possible values: Yes/No
	     Enable_SOL	Yes
	     ##	Possible values: Callback/User/Operator/Administrator/OEM_Proprietary
	     SOL_Privilege_Level Administrator
	     ##	Possible values: Yes/No
	     Force_SOL_Payload_Authentication Yes
	     ##	Possible values: Yes/No
	     Force_SOL_Payload_Encryption Yes
	     ##	Give a valid integer. Each unit	is 5ms
	     Character_Accumulate_Interval 50
	     ##	Give a valid number
	     Character_Send_Threshold 100
	     ##	Give a valid integer
	     SOL_Retry_Count 5
	     ##	Give a valid integer. Interval unit is 10ms
	     SOL_Retry_Interval	50
	     ##	Possible values: Serial/9600/19200/38400/57600/115200
	     Non_Volatile_Bit_Rate 115200
	     ##	Possible values: Serial/9600/19200/38400/57600/115200
	     Volatile_Bit_Rate 115200
	    EndSection

Section	User1, User2, ...
       The User	sections of the	BMC configuration file are for	username  con-
       figuration  for IPMI over LAN communication. The	number of users	avail-
       able to be configured on	your system will vary by  manufacturer.	  With
       the exception of	the Username for User1,	all sections are identical.

       The  username(s)	 you  wish  to configure the BMC with are defined with
       Username. The first username under Section User1	is typically the  NULL
       username	 and  cannot be	modified. The password for the username	can be
       specified with Password.	It can be left empty to	define	a  NULL	 pass-
       word.  Each  user  you  wish  to	enable must be enabled through the En-
       able_User configuration option. It is recommended  that	all  usernames
       have non-NULL passwords or be disabled for security reasons.

       Lan_Enable_Ipmi_Msgs  is	used to	enable or disable IPMI over LAN	access
       for the user. This should be set	to "Yes" to allow IPMI over LAN	 tools
       to work.

       Lan_Privilege_Limit  specifies  the  maximum  privilege level limit the
       user is allowed.	Different IPMI commands	have different	privilege  re-
       strictions. For example,	determining the	power status of	a machine only
       requires	the "User" privilege level. However,  power  cycling  requires
       the  "Operator"	privilege.  Typically, you will	want to	assign atleast
       one user	with a privilege limit of "Administrator" so that  all	system
       functions are available to atleast one user via IPMI over LAN.

       Lan_Session_Limit  specifies  the  number of simultaneous IPMI sessions
       allowed for the user. Most users	will wish to set this to "0" to	 allow
       unlimited simultaneous IPMI sessions. This field	is considered optional
       by IPMI standards, and may result in errors when	attempting to  config-
       ure  it to a non-zero value. If errors to occur,	setting	the value back
       to 0 should resolve problems.

       SOL_Payload_Access specifies if a particular user is allowed to connect
       with  Serial-Over-LAN  (SOL). This should be set	to "Yes" to allow this
       username	to use SOL.

       The example configuration above disables	"User2"	but  enables  the  de-
       fault  "NULL"  (i.e. anonymous) user. Many IPMI tools (both open-source
       and vendor) do not allow	the user to input a username  and  assume  the
       NULL  username by default. If the tools you are interested in using al-
       low usernames to	be input, then it is recommended that one of the  non-
       NULL  usernames	be enabled and the NULL	username disabled for security
       reasons.	It is recommeneded that	you disable the	NULL username in  sec-
       tion  User1,  so	that users are required	to specify a username for IPMI
       over LAN	communication.

       Some motherboards may require a Username	 to  be	 configured  prior  to
       other fields being read/written.	If this	is the case, those fields will
       be set to _username-not-set-yet_.

Section	Lan_Channel
       The Lan_Channel section configures a variety of IPMI over LAN  configu-
       ration parameters. Both Volatile	and Non_Volatile configurations	can be
       set. Volatile configurations are	immediately configured	onto  the  BMC
       and  will  have immediate effect	on the system. Non_Volatile configura-
       tions are only available	after the next system reset.  Generally,  both
       the Volatile and	Non_Volatile should be configured identically.

       The  Access_Mode	parameter configures the availability of IPMI over LAN
       on the system. Typically	this should be set  to	"Always_Available"  to
       enable IPMI over	LAN.

       The  Privilege_Limit  sets the maximum privilege	any user of the	system
       can have	when performing	IPMI over LAN. This should be set to the maxi-
       mum privilege level configured to a username. Typically,	this should be
       set to "Administrator".

       Typically User_Level_Auth and Per_Message_Auth should be	set  to	 "Yes"
       for additional security.	Disabling User_Level_Auth allows "User"	privi-
       leged IPMI commands to be executed  without  authentication.  Disabling
       Per_Message_Auth	 allows	 fewer individual IPMI messages	to require au-
       thentication.

Section	Lan_Conf
       Those familiar with setting up networks should find most	of the	fields
       in  this	 section self explanatory. The example BMC configuration above
       illustrates the	setup  of  a  static  IP  address.  The	 field	IP_Ad-
       dress_Source  is	configured with	"Static". The IP address, subnet mask,
       and gateway IP addresses	of the	machine	 are  respecitvely  configured
       with   the  IP_Address,	Subnet_Mask,  Default_Gateway_Ip_Address,  and
       Backup_Gateway_Ip_Address fields. The respective	MAC addresses for  the
       IP  addresses are configured under Mac_Address, Default_Gateway_Mac_Ad-
       dress, and Backup_Gateway_Mac_Address.

       It is not required to setup the BMC IP_Address to be the	same P_Address
       used  by	 your operating	system for that	network	interface. However, if
       you choose to use a different address, an alternate  ARP	 configuration
       may need	to be setup.

       To  instead  setup  your	 BMC  network  information via DHCP, the field
       IP_Address_Source should	be configured with "Use_DHCP".

       It is recommended that static IP	addresses be  configured  for  address
       resolution  reasons. See	Lan_Conf_Misc below for	a more detailed	expla-
       nation.

Section	Lan_Conf_Auth
       This section determines what types of  password	authentication	mecha-
       nisms  are  allowed  for	 users at different privilege levels under the
       IPMI 1.5	protocol. The currently	supported authentication  methods  for
       IPMI  1.5  are  None (no	username/password required), Straight_Password
       (passwords are sent in the clear), MD2 (passwords are MD2 hashed),  and
       MD5 (passwords are MD5 hashed).	Different usernames at different priv-
       ilege levels may	be allowed to authenticate  differently	 through  this
       configuration.  For  example,  a	username with "User" privileges	may be
       allowed to authenticate with a straight password, but a	username  with
       "Administrator" privileges may be allowed only authenticate with	MD5.

       The above example configuration supports	MD2 and	MD5 authentication for
       all users at the	"User",	"Operator", and	"Administrator"	privilege lev-
       els.  All  authentication  mechanisms have been disabled	for the	"Call-
       back" privilege level.

       Generally speaking, you do not want to allow any	user  to  authenticate
       with  None  or Straight_Password	for security reasons.  MD2 and MD5 are
       digital signature algorithms that can minimally encrypt	passwords.  If
       you  have  chosen to support the	NULL username (enabled User1) and NULL
       passwords (NULL password	for User1), you	will have to enable  the  None
       authentication fields above to allow users to connect via None.

Section	Lan_Conf_Security_Keys
       This  section supports configuration of the IPMI	2.0 (including Serial-
       over-LAN) K_g key. If your machine does	not  support  IPMI  2.0,  this
       field will not be configurable.

       The  key	is used	for two-key authentication in IPMI 2.0.	In most	tools,
       when doing IPMI 2.0, the	K_g can	be optionally specified. It is not re-
       quired for IPMI 2.0 operation.

       In  the above example, we have elected to leave this field blank	so the
       K_g key is not used.

Section	Lan_Conf_Misc
       This section lists miscellaneous	IPMI over LAN  configuration  options.
       These  are optional IPMI	configuration options that are not implemented
       on all BMCs.

       Normally, a client cannot resolve the ethernet MAC address without  the
       remote  operating system	running. However, IPMI over LAN	would not work
       when a machine is powered off or	if the IP address used by the  operat-
       ing  system for that network interface differs from the BMC IP Address.
       One way to work around this is  through	gratuitous  ARPs.   Gratuitous
       ARPs are	ARP packets generated by the BMC and sent out to advertise the
       BMC's IP	and MAC	address.  Other	machines on the	network	can store this
       information  in their local ARP cache for later IP/hostname resolution.
       This would allow	IPMI over LAN to work when the remote machine is  pow-
       ered  off.  The	Enable_Gratuitous_Arps	option allows you to enable or
       disable this feature. The Gratuitous_Arp_Interval option	allows you  to
       configure the frequency at which	gratuitous ARPs	are sent onto the net-
       work.

       Instead of gratuitous ARPs some BMCs are	able to	 respond  to  ARP  re-
       quests, even when powered off. If offerred, this	feature	can be enabled
       through the Enable_Arp_Response option.

       Generally speaking, turning on gratuitous ARPs is acceptable.  However,
       it  will	 increase traffic on your network.  If you are using IPMI on a
       large cluster, the gratuitous ARPs may easily flood your	network.  They
       should  be tuned	to occur less frequently or disabled. If disabled, the
       remote machine's	MAC address should be permanently stored in the	 local
       ARP cache through arp(8).

       See  bmc-watchdog(8)  for  a  method which allows gratuitous ARPs to be
       disabled	when the operating system is running,  but  enabled  when  the
       system is down.

Section	Rmcpplus_Conf_Privilege
       This  section supports configuration of the IPMI	2.0 (including Serial-
       over-LAN) cipher	suite IDs. If your machine does	not support IPMI  2.0,
       the fields will not be configurable.

       Each cipher suite ID describes a	combination of an authentication algo-
       rithm, integrity	algorithm, and encryption algorithm for	IPMI 2.0.  The
       authentication  algorithm is used for user authentication with the BMC.
       The integrity algorithm is used for generating signatures on IPMI pack-
       ets.  The  confidentiality  algorithm  is used for encrypting data. The
       configuration in	this section enables certain cipher suite  IDs	to  be
       enabled or disabled, and	the maximum privilege level a username can au-
       thenticate with.

       The following table shows the cipher suite ID to	algorithms mapping:

       0 - Authentication Algorithm = None; Integrity Algorithm	= None;	Confi-
       dentiality Algorithm = None

       1  -  Authentication Algorithm =	HMAC-SHA1; Integrity Algorithm = None;
       Confidentiality Algorithm = None

       2 - Authentication Algorithm = HMAC-SHA1; Integrity Algorithm  =	 HMAC-
       SHA1-96;	Confidentiality	Algorithm = None

       3  -  Authentication Algorithm =	HMAC-SHA1; Integrity Algorithm = HMAC-
       SHA1-96;	Confidentiality	Algorithm = AES-CBC-128

       4 - Authentication Algorithm = HMAC-SHA1; Integrity Algorithm  =	 HMAC-
       SHA1-96;	Confidentiality	Algorithm = xRC4-128

       5  -  Authentication Algorithm =	HMAC-SHA1; Integrity Algorithm = HMAC-
       SHA1-96;	Confidentiality	Algorithm = xRC4-40

       6 - Authentication Algorithm = HMAC-MD5;	Integrity  Algorithm  =	 None;
       Confidentiality Algorithm = None

       7  -  Authentication  Algorithm = HMAC-MD5; Integrity Algorithm = HMAC-
       MD5-128;	Confidentiality	Algorithm = None

       8 - Authentication Algorithm = HMAC-MD5;	Integrity  Algorithm  =	 HMAC-
       MD5-128;	Confidentiality	Algorithm = AES-CBC-128

       9  -  Authentication  Algorithm = HMAC-MD5; Integrity Algorithm = HMAC-
       MD5-128;	Confidentiality	Algorithm = xRC4-128

       10 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm  =	 HMAC-
       MD5-128;	Confidentiality	Algorithm = xRC4-40

       11  -  Authentication  Algorithm	 =  HMAC-MD5;  Integrity  Algorithm  =
       MD5-128;	Confidentiality	Algorithm = None

       12  -  Authentication  Algorithm	 =  HMAC-MD5;  Integrity  Algorithm  =
       MD5-128;	Confidentiality	Algorithm = AES-CBC-128

       13  -  Authentication  Algorithm	 =  HMAC-MD5;  Integrity  Algorithm  =
       MD5-128;	Confidentiality	Algorithm = xRC4-128

       14  -  Authentication  Algorithm	 =  HMAC-MD5;  Integrity  Algorithm  =
       MD5-128;	Confidentiality	Algorithm = xRC4-40

       Generally  speaking, HMAC-SHA1 based algorithms are stronger than HMAC-
       MD5, which are better than MD5-128  algorithms.	AES-CBC-128  confiden-
       tiality	algorithms  are	 stronger  than	xRC4-128 algorithms, which are
       better than xRC4-40 algorithms. Cipher suite ID 3  is  therefore	 typi-
       cally  considered  the  most  secure. Some users	may wish to set	cipher
       suite ID	3 to a privilege level and disable all remaining cipher	 suite
       IDs.

       The above example configuration has decided to allow any	user with "Ad-
       ministrator" privileges use any Cipher Suite algorithm suite which  re-
       quires  an  authentication,  integrity,	and confidentiality algorithm.
       Typically, the maximum privilege	level configured to a username	should
       be  set for atleast one cipher suite ID.	Typically, this	is the "Admin-
       istrator" privilege.

       A number	of cipher suite	IDs are	optionally implemented,	so the	avail-
       able cipher suite IDs available your system may vary.

Section	SOL_Conf
       This  section  is for setting up	Serial-Over-Lan	(SOL) and will only be
       available for configuration on those machines. SOL can be enabled  with
       the Enable_SOL field. The minimum privilege level required for connect-
       ing with	SOL is specified by SOL_Privilege_Level.  This should  be  set
       to  the	maximum	 privilege level configured to a username that has SOL
       enabled.	Typically, this	is the "Administrator" privilege.  Authentica-
       tion   and   Encryption	 can   be  forced  or  not  using  the	fields
       Force_SOL_Payload_Authentication	and  Force_SOL_Payload_Encryption  re-
       spectively. It is recommended that these	be set on. However, forced au-
       thentication and/or encryption support depend on	the cipher  suite  IDs
       supported.

       The     Character_Accumulate_Interval,	 Character_Send_Threshold    ,
       SOL_Retry_Count and , SOL_Retry_Interval	options	are used  to  set  SOL
       character  output  speeds. Character_Accumulate_Interval	determines how
       often serial data should	be regularly sent and Character_Send_Threshold
       indicates the character count that if passed, will force	serial data to
       be sent.	SOL_Retry_Count	indicates how many times packets must  be  re-
       transmitted  if	acknowledgements  are not received. SOL_Retry_Interval
       indicates the timeout interval. Generally, the manufacturer recommended
       numbers	will  be  sufficient. However, you may wish to experiment with
       these values for	faster SOL throughput.

       The Non_Volatile_Bit_Rate and Volatile_Bit_Rate determine the  baudrate
       the  BMC	should use. This should	match the baudrate set in the BIOS and
       operating system, such as  agetty(8).   Generally  speaking,  both  the
       Volatile	and Non_Volatile options should	be set identically.

       In addition to enabling SOL in this section, individual users most also
       be capable of connecting	with  SOL.  See	 the  section  Section	User1,
       User2, ...  above for details.

REPORTING BUGS
       Report bugs to <freeipmi-users@gnu.org> or <freeipmi-devel@gnu.org>.

SEE ALSO
       freeipmi(7), bmc-watchdog(8), ipmi-config(8), agetty(8)

       http://www.gnu.org/software/freeipmi/

ipmi-config 1.6.5		  2020-05-21		   ipmi-config.conf(5)