HobbyBoards_EE/EF(3)	     One-Wire File System	  HobbyBoards_EE/EF(3)

NAME
       UVI, Moisture, Barometer, HUB
	      -	 HobbyBoards  EE/EF  Microprocessor-based slaves: Ultra	Violet
	      (UV) Index sensor, Soil and Leaf moisture	measurements,  Barome-
	      ter, 4-channel hub with switchable branches

SYNOPSIS
   General EE device
       EE [.]XXXXXXXXXXXX[XX][/[ temperature | version | type_number | temper-
       ature_offset | address |	crc8 | id | locator | r_address	| r_id | r_lo-
       cator | type ]]

   UVI sensor
       EE  [.]XXXXXXXXXXXX[XX][/[  UVI/UVI  |  UVI/UVI_offset  | UVI/in_case |
       UVI/valid | temperature | version | type_number | temperature_offset ]]

   General EF device
       EF [.]XXXXXXXXXXXX[XX][/[ version | type_number | address | crc8	| id |
       locator | r_address | r_id | r_locator |	type ]]

   Moisture Meter
       moisture/sensor.[0-3|ALL]
       moisture/is_moisture.[0-3|ALL|BYTE] | moisture/is_leaf.[0-3|ALL|BYTE]
       moisture/calibrate/min	|   moisture/calibrate/max   |	moisture/cali-
       brate/raw.[0-4|ALL]

   Hub
       hub/branch.[0-3|ALL|BYTE] | hub/short.[0-3|ALL|BYTE]

FAMILY CODE
       EE     Device with temperature

       EE     UVI

       EF     Device without temperature

       EF     Moisture Meter

       EF     Hub

TEMPERATURE PROPERTIES
   temperature
       read-only, floating point
       Temperature read	every 30 seconds. Resolution  .5C  (uses  an  on-board
       DS18B20). Temperature is	only present in	the EE-series devices.

   temperature_offset
       read-write, floating point
       Offset stored on	device to apply	to temperature readings.

UVI PROPERTIES
   UVI/UVI
       read-only floating point
       UV Index	(ultraviolet index) in the range 0.0 to	16.0 resolution	.1

       Only  the  UVI version of the EE	device has a UVI sensor. Readings made
       every .5	seconds.

   UVI/UVI_offset
       read-write, floating point
       Signed offset to	apply to the UVI measurement.  Stored  on-device  non-
       volatile.

   UVI/in_case
       read-write, yes-no
       Flag  to	 apply	compensation for the protective	case. Stored on-device
       non-volatile.

   UVI/valid
       read-only, yes-no Flag the the EE device	type  matches  the  known  UVI
       type.

Moisture Meter
   moisture/sensor.0 ..	moisture/sensor.3 moisture/sensor.ALL
       read-only integer
       Up  to  4 sensors reading moisture can be attached.  OWFS addresses the
       sensors as 0 through 3 while the	datasheet uses 1-4.  Two types of  ex-
       ternal sensors are supported (and the data range):

       Watermark Soil Moisture Sensor
	      0-199

       Leaf Wetness Sensor
	      0-99

   moisture/is_moisture.0 .. moisture/is_moisture.3 moisture/is_moisture.ALL
   moisture/is_leaf.0 .. moisture/is_leaf.3 moisture/is_leaf.ALL
       read-write yes_no
       Set  or get the type of sensor attached to each channel.	Note that OWFS
       addresses the sensors as	0 through 3 while the datasheet	uses 1-4.  Two
       types of	external sensors are supported:

       Watermark Soil Moisture
	      Sensor

       Leaf Wetness
	      Sensor

       Note  that  is_leaf  and	is_moisture are	complementary and clearing one
       sets the	other.

   moisture/calibrate/min
   moisture/calibrate/max
       read-write unsigned integer
       Set or get the upper and	lower range for	the raw	data for leaf  wetness
       scaling.	See the	datasheet for details.

   moisture/calibrate/raw.0    ..    moisture/calibrate/raw.3	moisture/cali-
       brate/raw.ALL
       read-only unsigned integer
       Read the	raw leaf wetness values	for setting scaling. See the datasheet
       for details.  Note that OWFS addresses the sensors as 0 through 3 while
       the datasheet uses 1-4.

Hub
       4-channel hub. Individual branches can be switched on and off.

   hub/branch.0	.. hub/branch.3	hub/branch.ALL hub/branch.BYTE
       read-write, yes-no
       The HobbyBoards hub has four 1-wire bus lines. Each branch is  electri-
       caly  isolated  from  reflections and shorts, and can be	optionally ex-
       cluded from the 1-wire network.

       You can turn each branch	on or off by writing 0 (off) or	1 (on) to  the
       corresponding  property.	 Note  that  OWFS  indexes the branches	0 to 3
       while the datasheet uses	1 to 4.

       The easiest way to turn all the branches	on is to write	15  (0x0F)  to
       hub/branch.BYTE

   hub/short.0 .. hub/short.3 hub/short.ALL hub/short.BYTE
       read-only, yes-no
       Is the corresponding branch in "short" condition? (Electrically shorted
       out).

IDENTIFICATION PROPERTIES
   version
       read-only, ascii
       Firmware	version	for the	EE/EF device. Reported in nn.nn	 format	 where
       nn is major/minor decimal value.

       Note:  This  format was changed as of version owfs-2.9p6	at the request
       of the HobbyBoards. Formerly reported in	HH.HH format where HH is a hex
       digit (0-9A-F).

   type_number
       read-only, integer
       Index  of  the type of sensor built into	this device. Current known as-
       signments:

       1      UVI (Ultraviolet index)

       2      Moisture meter

       3      Moisture meter with datalogger

       4      Sniffer

       5      Hub

STANDARD PROPERTIES
   address
   r_address
       read-only, ascii
       The entire 64-bit unique	ID. Given as  upper  case  hexidecimal	digits
       (0-9A-F).
       address starts with the family code
       r address is the	address	in reverse order, which	is often used in other
       applications and	labeling.

   crc8
       read-only, ascii
       The 8-bit error correction portion. Uses	cyclic redundancy check.  Com-
       puted  from the preceding 56 bits of the	unique ID number. Given	as up-
       per case	hexadecimal digits (0-9A-F).

   family
       read-only, ascii
       The 8-bit family	code. Unique to	each type of device.  Given  as	 upper
       case hexadecimal	digits (0-9A-F).

   id
   r_id
       read-only, ascii
       The 48-bit middle portion of the	unique ID number. Does not include the
       family code or CRC. Given as upper case hexadecimal digits (0-9A-F).
       r id is the id in reverse order,	which is often used in other  applica-
       tions and labeling.

   locator
   r_locator
       read-only, ascii
       Uses  an	 extension  of the 1-wire design from iButtonLink company that
       associated 1-wire physical connections with a unique  1-wire  code.  If
       the  connection is behind a Link	Locator	the locator will show a	unique
       8-byte number (16 character hexadecimal)	starting with family code FE.
       If no Link Locator is between the device	and the	 master,  the  locator
       field will be all FF.
       r locator is the	locator	in reverse order.

   present (DEPRECATED)
       read-only, yes-no
       Is the device currently present on the 1-wire bus?

   type
       read-only, ascii
       Part  name  assigned by Dallas Semi. E.g.  DS2401 Alternative packaging
       (iButton	vs chip) will not be distiguished.

ALARMS
       None

DESCRIPTION
   1-Wire
       1-wire is a wiring protocol and series of devices designed and manufac-
       tured  by  Dallas  Semiconductor, Inc. The bus is a low-power low-speed
       low-connector scheme where the data line	can also provide power.

       Each device is uniquely and unalterably	numbered  during  manufacture.
       There  are a wide variety of devices, including memory, sensors (humid-
       ity, temperature, voltage, contact, current), switches, timers and data
       loggers.	 More complex devices (like thermocouple sensors) can be built
       with these basic	devices. There are also	1-wire devices that  have  en-
       cryption	included.

       The  1-wire  scheme uses	a single bus master and	multiple slaves	on the
       same wire. The bus master initiates all communication. The  slaves  can
       be individually discovered and addressed	using their unique ID.

       Bus  masters come in a variety of configurations	including serial, par-
       allel, i2c, network or USB adapters.

   OWFS	design
       OWFS is a suite of programs that	designed to make the  1-wire  bus  and
       its  devices easily accessible. The underlying principle	is to create a
       virtual filesystem, with	the unique ID being the	directory, and the in-
       dividual	 properties of the device are represented as simple files that
       can be read and written.

       Details of the individual slave or master design	are  hidden  behind  a
       consistent interface. The goal is to provide an easy set	of tools for a
       software	designer to create monitoring or control  applications.	 There
       are some	performance enhancements in the	implementation,	including data
       caching,	parallel access	to bus masters,	and aggregation	of device com-
       munication.  Still the fundamental goal has been	ease of	use, flexibil-
       ity and correctness rather than speed.

   EE /	EF
       The EEEF	(3) are	a reference platform of	 microprocessor	 based	1-wire
       slaves.	In  general  they require external power, and have an on-board
       index for the specific capabilities. They are designed by Eric  Vickery
       at HobbyBoards.com

       The EE class device uses	family code EE and has an included temperature
       sensor. The EF devices have no temperature sensor,

   UVI
       The UVI sensor is an implementation of the EE class device  with	 Ultra
       Violet  Index sensing. All it's specific	properties are in the UVI/ di-
       rectory.

ADDRESSING
       All 1-wire devices are factory assigned a unique	64-bit	address.  This
       address is of the form:

       Family Code
	      8	bits

       Address
	      48 bits

       CRC    8	bits

       Addressing under	OWFS is	in hexadecimal,	of form:

	      01.123456789ABC

       where 01	is an example 8-bit family code, and 12345678ABC is an example
       48 bit address.

       The dot is optional, and	the CRC	code can  included.  If	 included,  it
       must be correct.

DATASHEET
       UVI    http://www.hobby-boards.com/catalog/links/uvi2-r1/UVI%20Me-
	      ter%20User%20Manual.pdf

       Moisture	and Leaf Sensor
	      http://www.hobby-boards.com/download/manuals/Moisture%20Me-
	      ter.pdf

       4 Channel Hub
	      http://www.hobby-boards.com/download/manuals/4%20Chan-
	      nel%20Hub.pdf

SEE ALSO
   Programs
       owfs (1)	owhttpd	(1) owftpd (1)	owserver  (1)  owdir  (1)  owread  (1)
       owwrite (1) owpresent (1) owtap (1)

   Configuration and testing
       owfs (5)	owtap (1) owmon	(1)

   Language bindings
       owtcl (3) owperl	(3) owcapi (3)

   Clocks
       DS1427  (3)  DS1904  (3)	 DS1994	 (3) DS2404 (3)	DS2404S	(3) DS2415 (3)
       DS2417 (3)

   ID
       DS2401 (3) DS2411 (3) DS1990A (3)

   Memory
       DS1982 (3) DS1985 (3) DS1986 (3)	 DS1991	 (3)  DS1992  (3)  DS1993  (3)
       DS1995  (3)  DS1996  (3)	 DS2430A  (3) DS2431 (3) DS2433	(3) DS2502 (3)
       DS2506 (3) DS28E04 (3) DS28EC20 (3)

   Switches
       DS2405 (3) DS2406 (3) DS2408 (3)	DS2409 (3) DS2413 (3) DS28EA00 (3)

   Temperature
       DS1822 (3) DS1825 (3) DS1820 (3)	DS18B20	(3)  DS18S20  (3)  DS1920  (3)
       DS1921  (3) DS1821 (3) DS28EA00 (3) DS28E04 (3) EDS0064 (3) EDS0065 (3)
       EDS0066 (3) EDS0067 (3) EDS0068 (3) EDS0071 (3)	EDS0072	 (3)  MAX31826
       (3)

   Humidity
       DS1922 (3) DS2438 (3) EDS0065 (3) EDS0068 (3)

   Voltage
       DS2450 (3)

   Resistance
       DS2890 (3)

   Multifunction (current, voltage, temperature)
       DS2436  (3)  DS2437  (3)	 DS2438	 (3)  DS2751 (3) DS2755	(3) DS2756 (3)
       DS2760 (3) DS2770 (3) DS2780 (3)	DS2781 (3) DS2788 (3) DS2784 (3)

   Counter
       DS2423 (3)

   LCD Screen
       LCD (3) DS2408 (3)

   Crypto
       DS1977 (3)

   Pressure
       DS2406 (3) TAI8570 (3) EDS0066 (3) EDS0068 (3)

   Moisture
       EEEF (3)	DS2438 (3)

AVAILABILITY
       http://www.owfs.org

AUTHOR
       Paul Alfille (paul.alfille@gmail.com)

OWFS Manpage			     2009		  HobbyBoards_EE/EF(3)