Skip site navigation (1)Skip section navigation (2)

FreeBSD Manual Pages

  
 
  

home | help
SNMP::Info::Layer3::C3User3Contributed Perl DocumeSNMP::Info::Layer3::C3550(3)

NAME
       SNMP::Info::Layer3::C3550 - SNMP	Interface to Cisco Catalyst 3550 Layer
       2/3 Switches running IOS

AUTHOR
       Max Baker

SYNOPSIS
	# Let SNMP::Info determine the correct subclass	for you.
	my $c3550 = new	SNMP::Info(
			       AutoSpecify => 1,
			       Debug	   => 1,
			       # These arguments are passed directly to	SNMP::Session
			       DestHost	   => 'myswitch',
			       Community   => 'public',
			       Version	   => 2
			       )
	   or die "Can't connect to DestHost.\n";

	my $class      = $c3550->class();
	print "SNMP::Info determined this device to fall under subclass	: $class\n";

DESCRIPTION
       Abstraction subclass for	Cisco Catalyst 3550 Layer 2/3 Switches.

       These devices run IOS but have some of the same characteristics as the
       Catalyst	WS-C family (5xxx,6xxx).  For example, forwarding tables are
       held in VLANs, and extended interface information is gleaned from
       CISCO-SWITCH-MIB.

       For speed or debugging purposes you can call the	subclass directly, but
       not after determining a more specific class using the method above.

	my $c3550 = new	SNMP::Info::Layer3::C3550(...);

   Inherited Classes
       SNMP::Info::CiscoStack
       SNMP::Info::Layer3::CiscoSwitch

   Required MIBs
       Inherited Classes' MIBs
	   See "Required MIBs" in SNMP::Info::CiscoStack for its own MIB
	   requirements.

	   See "Required MIBs" in SNMP::Info::Layer3::CiscoSwitch for its own
	   MIB requirements.

GLOBALS
       These are methods that return scalar value from SNMP

       $c3550->vendor()
	   Returns 'cisco'

       $c3550->model()
	   Will	take the translated model number and try to format it better.

	    355048 -> 3550-48
	    355012G -> 3550-12G

       $c3550->ports()
	   Tries to cull the number of ports from the model number.

   Globals imported from SNMP::Info::CiscoStack
       See documentation in "GLOBALS" in SNMP::Info::CiscoStack	for details.

   Globals imported from SNMP::Info::Layer3::CiscoSwitch
       See documentation in "GLOBALS" in SNMP::Info::Layer3::CiscoSwitch for
       details.

TABLE METHODS
       These are methods that return tables of information in the form of a
       reference to a hash.

   Overrides
       $c3550->i_duplex()
	   Returns reference to	hash of	iid to current link duplex setting.

	   Software version 12.1(22)EA1a or greater returns duplex based upon
	   the result of $c3550->el_duplex().  Otherwise it uses the result of
	   the call to CiscoStack::i_duplex().

	   See SNMP::Info::Etherlike for el_duplex() method and
	   SNMP::Info::CiscoStack for its i_duplex() method.

       $c3550->i_duplex_admin()
	   Returns reference to	hash of	iid to administrative duplex setting.

	   Software version 12.1(22)EA1a or greater returns duplex based upon
	   the result of $c3550->p_duplex().  Otherwise	it uses	the result of
	   the call to CiscoStack::i_duplex().

	   See SNMP::Info::CiscoStack for its i_duplex() and p_duplex()
	   methods.

       $c3550->set_i_duplex_admin(duplex, ifIndex)
	   Sets	port duplex, must be supplied with duplex and port "ifIndex".

	   Speed choices are 'auto', 'half', 'full'.

	   Crosses $c3550->p_port() with $c3550->p_duplex() to utilize port
	   "ifIndex".

	       Example:
	       my %if_map = reverse %{$c3550->interfaces()};
	       $c3550->set_i_duplex_admin('auto', $if_map{'FastEthernet0/1'})
		   or die "Couldn't change port	duplex.	",$c3550->error(1);

   Table Methods imported from SNMP::Info::CiscoStack
       See documentation in "TABLE METHODS" in SNMP::Info::CiscoStack for
       details.

   Table Methods imported from SNMP::Info::Layer3::CiscoSwitch
       See documentation in "TABLE METHODS" in SNMP::Info::Layer3::CiscoSwitch
       for details.

perl v5.32.0			  2020-08-09	  SNMP::Info::Layer3::C3550(3)