EDS00xx(3)		     One-Wire File System		    EDS00xx(3)

NAME
       EDS - Embedded Data Systems Sensors

       EDS0064
	      -	Temperature

       EDS0065
	      -	Temperature and	Humidity

       EDS0066
	      -	Temperature and	Barometric Pressure

       EDS0067
	      -	Temperature and	Light

       EDS0068
	      -	Temperature, Barometric	Pressure and Light

       EDS0070
	      -	Vibration

       EDS0071
	      -	RTD 4-wire temperature

       EDS0072
	      -	RTD 3-wire temperature

       EDS0080
	      -	8 Channel Analog Current Input

       EDS0082
	      -	8 Channel Analog Voltage Input

       EDS0083
	      -	4 Channel Analog Current Input

       EDS0085
	      -	4 Channel Analog Voltage Input

       EDS0090
	      -	8 Discrete I/O

SYNOPSIS
       Embedded	Data Systems microprocessor-based sensors

   Sub-type ( all )
       7E [.]XXXXXXXXXXXX[XX][/[ device_id | device_type | tag ]]

   Memory ( all	)
       7E [.]XXXXXXXXXXXX[XX][/[ memory	| pages/page.[0-2|ALL] ]]

   Standard ( all )
       7E  [.]XXXXXXXXXXXX[XX][/[  address | crc8 | id | locator | r_address |
       r_id | r_locator	| type ]]

   Temperature ( EDS0064/5/6/7/8 )
       7E.XXXXXXXXXXXX/EDS006X	 [/[   temperature   |	 counters/seconds    |
       alarm/temp_[hi|low]  |  alarm/clear | set_alarm/temp_[hi|low] | thresh-
       old/temp_[hi|low] ]]

   Humidity ( EDS0065/8	)
       7E.XXXXXXXXXXXX/EDS006X [/[ humidity | humidex |	dew_point | heat_index
       |      alarm/humidity_[hi|low]	   |	  alarm/humidex_[hi|low]     |
       alarm/dew_point_[hi|low]	| alarm/heat_index_[hi|low]  |	alarm/clear  |
       set_alarm/humidity_[hi|low]	|     set_alarm/humidex_[hi|low]     |
       set_alarm/dew_point_[hi|low] | set_alarm/heat_index_[hi|low] |  thresh-
       old/humidity_[hi|low] |
       threshold/humidex_[hi|low]  |  threshold/dew_point_[hi|low]  |  thresh-
       old/heat_index_[hi|low] ]]

   Barometric Pressure ( EDS0066/8 )
       7E.XXXXXXXXXXXX/EDS006X [/[ pressure | inHg | alarm/pressure_[hi|low] |
       alarm/inHg_[hi|low]   |	alarm/clear  |	set_alarm/pressure_[hi|low]  |
       set_alarm/inHg_[hi|low]	 |   threshold/pressure_[hi|low]   |   thresh-
       old/inHg_[hi|low] ]]

   Light ( EDS0067/8 )
       7E.XXXXXXXXXXXX/EDS006X	[/[ light | alarm/light_[hi|low] | alarm/clear
       | set_alarm/light_[hi|low] | threshold/light_[hi|low] ]]

   Vibration ( EDS0070 )
       7E.XXXXXXXXXXXX/EDS0070 [/[ vib_level | vib_peak	| vib_min | vib_max  |
       counter/seconds	   |	 alarm/vib_[hi|low]	|     alarm/clear    |
       set_alarm/vib_[hi|low] |	threshold/vib_[hi|low] ]]

   RTD Temperature ( EDS0071/2 )
       7E.XXXXXXXXXXXX/EDS007X [/[ temperature | resistance | raw  |  delay  |
       user_byte  |  calibration/[key|constant]	 | counter/[seconds|samples] |
       alarm/temp_[hi|low]    |	   alarm/RTD_[hi_low]	 |    alarm/clear    |
       set_alarm/temp_[hi|low]	   |	set_alarm/RTD_[hi_low]	  |    thresh-
       old/temp_[hi|low] | threshold/RTD_[hi_low] ]]

   Analog Current ( EDS0080 [0-7] EDS0083 [0-3]	)
       7E.XXXXXXXXXXXX/EDS0080 [/[ current.[0-7|ALL] | max_current.[0-7|ALL] |
       min_current.[0-7|ALL] | threshold/current_hi.[0-7|ALL] |	threshold/cur-
       rent_low.[0-7|ALL]  |  alarm/current_hi.[0-7|ALL|BYTE]	|   alarm/cur-
       rent_low.[0-7|ALL|BYTE]	  |    set_alarm/current_hi.[0-7|ALL|BYTE]   |
       set_alarm/current_low.[0-7|ALL|BYTE]  |	counter/seconds	 |  memory   |
       pages/page.[0-4|ALL]

   Analog Voltage ( EDS0082 [0-7] EDS0085 [0-3]	)
       7E.XXXXXXXXXXXX/EDS0082	[/[  volts.[0-7|ALL]  |	 max_volts.[0-7|ALL] |
       min_volts.[0-7|ALL]   |	  threshold/volts_hi.[0-7|ALL]	  |    thresh-
       old/volts_low.[0-7|ALL]	    |	   alarm/volts_hi.[0-7|ALL|BYTE]     |
       alarm/volts_low.[0-7|ALL|BYTE]  |  set_alarm/volts_hi.[0-7|ALL|BYTE]  |
       set_alarm/volts_low.[0-7|ALL|BYTE]   |	counter/seconds	  |  memory  |
       pages/page.[0-4|ALL]

   I/O ( EDS0090 )
       7E.XXXXXXXXXXXX/EDS009X	[/[  input.[0-7|ALL]  |	  counter/[seconds   |
       pulses.[0-7|ALL]|reset.[0-7|ALL|BYTE]]		   |		  out-
       put/[set.[0-7|ALL|BYTE]|off.[0-7|ALL|BYTE]|reset.[0-7|ALL|BYTE]]	     |
       latch/[state.[0-7|ALL|BYTE]|reset.[0-7|ALL|BYTE]]		     |
       alarm/[hi.[0-7|ALL]|low.[0-7|ALL]|clear]				     |
       set_alarm/[hi.[0-7|ALL]|low.[0-7|ALL]]

   LED ( all )
       7E.XXXXXXXXXXXX/EDS00XX/LED/[state|control]

   relay ( all )
       7E.XXXXXXXXXXXX/EDS00XX/relay/[state|control]

FAMILY CODE
       7E

TEMPERATURE
   EDS006X/temperature
       read-only, floating-point
       Temperature for the EDS006X series of chips. In the -55C	to 125C	range,
       with 0.0636C precision. The temperature is read every second,  continu-
       ally.  Data is presented	in the specified temperature scale, Celsius by
       default.

   EDS007X/temperature
       read-only, floating-point
       Temperature for the EDS007X series of chips. Read  using	 a  wide-range
       precise	RTD sensor. Typical range is -60C to 260C with 0.15C accuracy,
       although	a range	of -200C to 850C is possible. The temperature is  read
       every  second unless a longer EDS007X/delay is given. Data is presented
       in the specified	temperature scale, Celsius by default.

   EDS007X/resistance
       read-only, floating-point
       Actual measured resistance (Ohms) of the	RTD element. Useful if the RTD
       element doesn't conform to the typical European IEC 60751 standard.

HUMIDITY
   EDS006X/humidity
       read-only, floating-point
       Relative	humidity in the	0-100 range (percent). Read every 0.2 seconds.

   EDS006X/dew_point
       read-only, floating-point
       Dew  point  computed from EDS006X/temperature and EDS006X/humidity com-
       putered every 0.2 seconds. Data is a calculated temperature and is  re-
       ported in the specified temperature scale. Default Celsius.

   EDS006X/heat_index
       read-only, floating-point
       Heat  index computed from EDS006X/temperature and EDS006X/humidity com-
       putered every 0.2 seconds. Data is a calculated temperature and is  re-
       ported in the specified temperature scale. Default Celsius.

   EDS006X/humidex
       read-only, floating-point
       Humidex	(popular  in  Canada)  computed	 from  EDS006X/temperature and
       EDS006X/humidity	computed every 0.2 seconds. Data is a percent and  re-
       ported in the 0-100 range.

LIGHT
   EDS006X/light
       read-only, unsigned integer
       Ambient light in	Lux. Measured every 0.2	seconds.

PRESSURE
   EDS006X/pressure
       read-only, floating-point
       Ambient	pressure,  measured  every  0.2	 seconds. Data in the selected
       pressure	scale (default mBar).

   EDS006X/inHg
       read-only, floating-point
       Ambient pressure, measured every	0.2 seconds. Data in the inHg scale.

VIBRATION
   EDS0070/vib_level
       read_only, unsigned integer
       Vibration registered by sensor (instantaneous value) in 0-1023 range.

   EDS0070/vib_peak
       read_only, unsigned integer
       Vibration registered by sensor (highest recent value -- slowly  decays)
       in 0-1023 range.

   EDS0070/vib_min
       read_only, unsigned integer
       Vibration registered by sensor (lowest value) in	0-1023 range.

   EDS0070/vib_max
       read_only, unsigned integer
       Vibration registered by sensor (highest value) in 0-1023	range.

CURRENT
       The EDS0080 and EDS0083 measure current in the 4-20mA range, with upper
       and threshold limits and	the ability to set an alarm and	 independently
       trigger a relay if the value is out of range.

   EDS0080/current.[0-7|ALL] EDS0083/current.[0-3|ALL]
       read-only, floating point
       Current current level. (4-20mA)

   EDS0080/max_current.[0-7|ALL] EDS0080/max_current.[0-3|ALL]
   EDS0083/min_current.[0-7|ALL] EDS0083/min_current.[0-3|ALL]
       read-only, floating point
       Maximum and minimum current readings since last alarm/clear command.

VOLTAGE
       The  EDS0082 and	EDS0085	measure	voltage	in the 0-10V range, with upper
       and threshold limits and	the ability to set an alarm and	 independently
       trigger a relay if the value is out of range.

   EDS0082/volts.[0-7|ALL] EDS0085/volts.[0-3|ALL]
       read-only, floating point
       Current voltage level. (0-10V)

   EDS0082/max_volts.[0-7|ALL] EDS0085/max_volts.[0-3|ALL]
   EDS0082/min_volts.[0-7|ALL] EDS0085/min_volts.[0-3|ALL]
       read-only, floating point
       Maximum and minimum voltage readings since last alarm/clear command.

THRESHOLD
       High  and  low range of acceptable sensor readings. Values outside this
       range will trigger an alarm if the corresponding	EDS00XX/set_alarm flag
       is set.

   EDS00XX/threshold/temp_hi EDS00XX/threshold/temp_low
       read-write, floating-point
       Threshold temperatures in the specified temperature scale. Default Cel-
       sius.

   EDS006X/threshold/humidity_hi EDS006X/threshold/humidity_low
   EDS006X/threshold/dew_point_hi EDS006X/threshold/dew_point_low
   EDS006X/threshold/heat_index_hi EDS006X/threshold/heat_index_low
   EDS006X/threshold/humidex_hi	tEDS006X/threshold/humidex_low
       read-write, floating-point
       Threshold humidity values.  Dew point and Heat index are	in the	speci-
       fied temperature	scale. Default Celsius.

   EDS006X/threshold/pressure_hi EDS006X/threshold/pressure_low
   EDS006X/threshold/inHg_hi EDS006X/threshold/inHg_low
       read-write, floating-point
       Threshold  barometric pressure values.  Pressure	is the specified pres-
       sure scale. Default mBar.

   EDS006X/threshold/light_hi EDS006X/threshold/light_low
       read-write, unsigned
       Threshold light (lux) values.

   EDS0070/threshold/vib_hi EDS0070/threshold/vib_low
       read-write, unsigned
       Vibration sensor	alarm limits in	0-1023 range.

   EDS007X/threshold/resistance_hi EDS007X/threshold/resistance_low
       read-write, floating-point
       Threshold RTD resistance	values (Ohm).

   EDS0080/threshold/current_hi.[0-7|ALL]		EDS0080/threshold/cur-
       rent_low.[0-7|ALL]
   EDS0082/threshold/volts_hi.[0-7|ALL]	EDS0082/threshold/volts_low.[0-7|ALL]
   EDS0083/threshold/current_hi.[0-3|ALL		EDS0083/threshold/cur-
       rent_low.[0-3|ALL]
   EDS0085/threshold/volts_hi.[0-3|ALL]	EDS0085/threshold/volts_low.[0-3|ALL|]
       read-write, floating-point
       Voltage or current threshold limits

SET ALARM
       Set conditional alarm to	trigger	if corresponding  flag	is  set.  Also
       must set	high and low threshold.

   EDS00XX/set_alarm/temp_hi EDS00XX/set_alarm/temp_low
   EDS006X/set_alarm/humidity_hi EDS006X/set_alarm/humidity_low
   EDS006X/set_alarm/dew_point_hi EDS006X/set_alarm/dew_point_low
   EDS006X/set_alarm/heat_index_hi EDS006X/set_alarm/heat_index_low
   EDS006X/set_alarm/humidex_hi	EDS006X/set_alarm/humidex_low
   EDS006X/set_alarm/pressure_hi EDS006X/set_alarm/pressure_low
   EDS006X/set_alarm/inHg_hi EDS006X/set_alarm/inHg_low
   EDS006X/set_alarm/light_hi EDS006X/set_alarm/light_low
   EDS0070/set_alarm/vib_hi EDS0070/set_alarm/vib_low
   EDS007X/set_alarm/resistance_hi EDS007X/set_alarm/resistance_low
   EDS0080/set_alarm/current_hi.[0-7|ALL|BYTE]		EDS0080/set_alarm/cur-
       rent_low.[0-7|ALL|BYTE]
   EDS0082/set_alarm/volts_hi.[0-7|ALL|BYTE]
       EDS0082/set_alarm/volts_low.[0-7|ALL|BYTE]
   EDS0083/set_alarm/current_hi.[0-3|ALL|BYTE]		EDS0083/set_alarm/cur-
       rent_low.[0-3|ALL|BYTE]
   EDS0085/set_alarm/volts_hi.[0-3|ALL|BYTE]
       EDS0085/set_alarm/volts_low.[0-3|ALL|BYTE]
       read-write, yes-no
       Flag  to	 set  corresponding out-of-range alarm.	"1" turns on flag, and
       "0" turns off.

ALARM
       Show or clear the out-of-range flags. When set, the device will respond
       to  a  conditional  search.  Clearing  the  flags is performed with the
       EDS00XX/alarm/clear command, not	just having the	measured value	return
       to the center range.

   EDS00XX/alarm/clear
       write-only, yes-no
       Write "1" to clear ALL the alarm	flags.

   EDS00XX/alarm/temp_hi EDS00XX/alarm/temp_low
   EDS006X/alarm/humidity_hi EDS006X/alarm/humidity_low
   EDS006X/alarm/dew_point_hi EDS006X/alarm/dew_point_low
   EDS006X/alarm/heat_index_hi EDS006X/alarm/heat_index_low
   EDS006X/alarm/humidex_hi EDS006X/alarm/humidex_low
   EDS006X/alarm/pressure_hi EDS006X/alarm/pressure_low
   EDS006X/alarm/inHg_hi EDS006X/alarm/inHg_low
   EDS006X/alarm/light_hi EDS006X/alarm/light_low
   EDS0070/alarm/vib_hi	EDS007X/alarm/vib_low
   EDS007X/alarm/resistance_hi EDS007X/alarm/resistance_low
   EDS0080/alarm/current_hi.[0-7|ALL|BYTE]		    EDS0080/alarm/cur-
       rent_low.[0-7|ALL|BYTE]
   EDS0082/alarm/volts_hi.[0-7|ALL|BYTE]
       EDS0082/alarm/volts_low.[0-7|ALL|BYTE]
   EDS0083/alarm/current_hi.[0-3|ALL|BYTE]		    EDS0083/alarm/cur-
       rent_low.[0-3|ALL|BYTE]
   EDS0085/alarm/volts_hi.[0-3|ALL|BYTE]
       EDS0085/alarm/volts_low.[0-3|ALL|BYTE]
   EDS0090/alarm/hi[0-7|ALL] EDS0090/alarm/low[0-7|ALL]
       read-only, yes-no
       Show  corresponding  out-of-range  alarm. "1" means in alarm state. Can
       only be turned off with clear

RELAY
       Optionally found	on the EDS006X and EDS007X. Can	be controlled by soft-
       ware or the alarm condition.

   EDS00XX/relay/control
       read-write, unsigned
       Set the relay control scheme:

       0      alarm control with hysteresis

       1      alarm control but	need EDS00XX/alarm/clear to unset

       2      Control with EDS00XX/relay/state

       3      Always off

   EDS00XX/relay/state
       read-write, yes-no
       Turn the	relay on or off	if the EDS00XX/relay/control is	set to 2

LED light
       Found  on the EDS006X and EDS007X. Can be controlled by software	or the
       alarm condition.

   EDS00XX/LED/control
       read-write, unsigned
       Set the LED control scheme:

       0      alarm control with hysteresis

       1      alarm control but	need EDS00XX/alarm/clear to unset

       2      Control with EDS00XX/LED/state

       3      Always off

   EDS00XX/LED/state
       read-write, yes-no
       Turn the	LED on or off if the EDS00XX/LED/control is set	to 2

COUNTER
   EDS00XX/counter/seconds
       read-only, unsigned integer
       Approximate seconds since power up.

   EDS0090/counter/pulses.0-7 |	ALL
       read-only, unsigned integer
       Pulses on each channel since power up or	reset. Channel should  be  set
       to input	( EDS0090/output/set.x =0 )

   EDS0090/counter/reset.0-7 | ALL | BYTE
       read-write, yes-no
       Clear the pulse count on	the corresponding channel.

   EDS007X/counter/samples
       read-only, unsigned integer
       Approximate samples since power up.

MEMORY
   memory
       read-write, binary
       96 bytes	of memory. Not all is writable.	Access to EDS00XX functions is
       better accomplished through the data fields, which expose all the  chip
       features.

   pages/page.0	... pages/page.2 pages/page.ALL
       read-write, binary
       Memory is split into 3 pages of 32 bytes	each. Only page	2 is writable.
       ALL is an aggregate of the pages. Each page is accessed sequentially.

   EDS008X/memory
       read-write, binary
       160 bytes of memory. Not	all is writable. Access	to  EDS008X  functions
       is  better  accomplished	 through the data fields, which	expose all the
       chip features. The EDS008X has more memory than the other chips,	 so  a
       separate	entry in the sudbirectory makes	it available.

   EDS008X/pages/page.0-4 EDS008X/pages/page.ALL
       read-write, binary
       Memory is split into 5 pages of 32 bytes	each. Only page	5 is writable.
       The EDS008X has more memory than	the other chips, so a  separate	 entry
       in  the sudbirectory makes the extra pages available.  ALL is an	aggre-
       gate of the pages. Each page is accessed	sequentially.

SUB-TYPE
   tag
       read-only, ascii
       Text description	of the device. Up to 30	characters.

   device_type
       read-only, ascii
       Device name. E.g: "EDS0071"

   device_id
       read-only, unsigned
       Number corresponding to the hexidecimal type. E.g:
       EDS0071 -> 0x0071 -> 113	in decimal

STANDARD PROPERTIES
   address
   r_address
       read-only, ascii
       The entire 64-bit unique	ID. Given as  upper  case  hexidecimal	digits
       (0-9A-F).
       address starts with the family code
       r address is the	address	in reverse order, which	is often used in other
       applications and	labeling.

   crc8
       read-only, ascii
       The 8-bit error correction portion. Uses	cyclic redundancy check.  Com-
       puted  from the preceding 56 bits of the	unique ID number. Given	as up-
       per case	hexidecimal digits (0-9A-F).

   family
       read-only, ascii
       The 8-bit family	code. Unique to	each type of device.  Given  as	 upper
       case hexidecimal	digits (0-9A-F).

   id
   r_id
       read-only, ascii
       The 48-bit middle portion of the	unique ID number. Does not include the
       family code or CRC. Given as upper case hexidecimal digits (0-9A-F).
       r id is the id in reverse order,	which is often used in other  applica-
       tions and labeling.

   locator
   r_locator
       read-only, ascii
       Uses  an	 extension  of the 1-wire design from iButtonLink company that
       associated 1-wire physical connections with a unique  1-wire  code.  If
       the  connection is behind a Link	Locator	the locator will show a	unique
       8-byte number (16 character hexidecimal)	starting with family code FE.
       If no Link Locator is between the device	and the	 master,  the  locator
       field will be all FF.
       r locator is the	locator	in reverse order.

   present (DEPRECATED)
       read-only, yes-no
       Is the device currently present on the 1-wire bus?

   type
       read-only, ascii
       Part  name  assigned by Dallas Semi. E.g.  DS2401 Alternative packaging
       (iButton	vs chip) will not be distiguished.

ALARMS
       None.

DESCRIPTION
   1-Wire
       1-wire is a wiring protocol and series of devices designed and manufac-
       tured  by  Dallas  Semiconductor, Inc. The bus is a low-power low-speed
       low-connector scheme where the data line	can also provide power.

       Each device is uniquely and unalterably	numbered  during  manufacture.
       There  are a wide variety of devices, including memory, sensors (humid-
       ity, temperature, voltage, contact, current), switches, timers and data
       loggers.	 More complex devices (like thermocouple sensors) can be built
       with these basic	devices. There are also	1-wire devices that  have  en-
       cryption	included.

       The  1-wire  scheme uses	a single bus master and	multiple slaves	on the
       same wire. The bus master initiates all communication. The  slaves  can
       be individually discovered and addressed	using their unique ID.

       Bus  masters come in a variety of configurations	including serial, par-
       allel, i2c, network or USB adapters.

   OWFS	design
       OWFS is a suite of programs that	designed to make the  1-wire  bus  and
       its  devices  easily accessible.	The underlying priciple	is to create a
       virtual filesystem, with	the unique ID being the	directory, and the in-
       dividual	 properties of the device are represented as simple files that
       can be read and written.

       Details of the individual slave or master design	are  hidden  behind  a
       consistent interface. The goal is to provide an easy set	of tools for a
       software	designer to create monitoring or control  applications.	 There
       are some	performance enhancements in the	implementation,	including data
       caching,	parallel access	to bus masters,	and aggregation	of device com-
       munication.  Still the fundemental goal has been	ease of	use, flexibil-
       ity and correctness rather than speed.

   EDS00XX Overview
       The EDS00XX sensors are a family	of devices from	Embedded Data Systems.
       Although	 provisional support for several types is included, only early
       EDS0071 has been	tested with OWFS.

       The sensors all share the same 7E family	code. They have	the same first
       memory  page layout with	a text tag property that describes them, and a
       sub-type	field giving the particular sensor. The	data properties	 shown
       in a directory listing will be specific to the sensor sub-type.

   EDS0071
       The  EDS0071  (3)  is  a	micro-processor	based 1-wire slave made	by EDS
       (Embedded Data Systams).	Is uses	a high accuracy	and extended range RTD
       sensor to accurately measure temperatures.

   Memory
       The EDS00XX sensors are read and	controlled by accessing	parts of their
       on-chip memory. Although	the raw	memory contents	 are  exposed  in  the
       memory  and  pages  fields, all the available functionality is best ac-
       cessed by the other fields. In fact, directly changing memory will con-
       fuse OWFS.

   Relay and LED
       All  the	 EDS00XX  sensors  have	an LED and optional relay. Both	can be
       controlled either directly, or when the sensors reaches an alarm	state.

ADDRESSING
       All 1-wire devices are factory assigned a unique	64-bit	address.  This
       address is of the form:

       Family Code
	      8	bits

       Address
	      48 bits

       CRC    8	bits

       Addressing under	OWFS is	in hexidecimal,	of form:

	      01.123456789ABC

       where 01	is an example 8-bit family code, and 12345678ABC is an example
       48 bit address.

       The dot is optional, and	the CRC	code can  included.  If	 included,  it
       must be correct.

DATASHEET
       EDS0064 EDS0065 EDS0066 EDS0067 EDS0068
	      https://docs.google.com/viewer?a=v&pid=explorer&chrome=true&sr-
	      cid=0B_K3iXLLAI7vN2E4NGUwMGItMzc5MS00NDNmLTljZ-
	      GYtN2NmM2Q3YWE5NmVh&hl=en

       EDS0070
	      http://www.embeddeddatasystems.com/assets/images/support-
	      Files/manuals/EN-UserMan%20%20OW-Vibration%20V01.pdf

       EDS0071 EDS0072
	      https://docs.google.com/viewer?a=v&pid=explorer&chrome=true&sr-
	      cid=0B_K3iXLLAI7vMjVhNWQzYzItZTRhMi00NGY2LWI4NTQtYjZlYT-
	      gzYzY0NmNm&hl=en

       EDS0080 EDS0083
	      https://eds.zendesk.com/attachments/token/ul-
	      npj6mvpp6yzwo/?name=EN-USERMAN+OW-IO-AIX-420+v1p0.pdf

       EDS0082 EDS0085
	      https://eds.zendesk.com/attachments/to-
	      ken/vyai6ylpw6edala/?name=EN-USERMAN+OW-IO-AIX-10V+v1p0.pdf

       EDS0090
	      8	Discrete I/O

SEE ALSO
   Programs
       owfs (1)	owhttpd	(1) owftpd (1)	owserver  (1)  owdir  (1)  owread  (1)
       owwrite (1) owpresent (1) owtap (1)

   Configuration and testing
       owfs (5)	owtap (1) owmon	(1)

   Language bindings
       owtcl (3) owperl	(3) owcapi (3)

   Clocks
       DS1427  (3)  DS1904(3)  DS1994  (3)  DS2404  (3)	DS2404S	(3) DS2415 (3)
       DS2417 (3)

   ID
       DS2401 (3) DS2411 (3) DS1990A (3)

   Memory
       DS1982 (3) DS1985 (3) DS1986 (3)	 DS1991	 (3)  DS1992  (3)  DS1993  (3)
       DS1995  (3)  DS1996  (3)	 DS2430A  (3) DS2431 (3) DS2433	(3) DS2502 (3)
       DS2506 (3) DS28E04 (3) DS28EC20 (3)

   Switches
       DS2405 (3) DS2406 (3) DS2408 (3)	DS2409 (3) DS2413 (3) DS28EA00 (3)

   Temperature
       DS1822 (3) DS1825 (3) DS1820 (3)	DS18B20	(3)  DS18S20  (3)  DS1920  (3)
       DS1921  (3) DS1821 (3) DS28EA00 (3) DS28E04 (3) EDS0064 (3) EDS0065 (3)
       EDS0066 (3) EDS0067 (3) EDS0068 (3) EDS0071 (3)	EDS0072	 (3)  MAX31826
       (3)

   Humidity
       DS1922 (3) DS2438 (3) EDS0065 (3) EDS0068 (3)

   Voltage
       DS2450 (3)

   Resistance
       DS2890 (3)

   Multifunction (current, voltage, temperature)
       DS2436  (3)  DS2437  (3)	 DS2438	 (3)  DS2751 (3) DS2755	(3) DS2756 (3)
       DS2760 (3) DS2770 (3) DS2780 (3)	DS2781 (3) DS2788 (3) DS2784 (3)

   Counter
       DS2423 (3)

   LCD Screen
       LCD (3) DS2408 (3)

   Crypto
       DS1977 (3)

   Pressure
       DS2406 (3) TAI8570 EDS0066 (3) EDS0068 (3)

   Moisture
       EEEF (3)	DS2438 (3)

AVAILABILITY
       http://www.owfs.org

AUTHOR
       Paul Alfille (paul.alfille@gmail.com)

OWFS Manpage			     2003			    EDS00xx(3)