SDPCONTROL(8)		FreeBSD	System Manager's Manual		 SDPCONTROL(8)

NAME
     spdcontrol	-- SDP query utility

SYNOPSIS
     spdcontrol	-h
     spdcontrol	-a address command [parameters ...]
     spdcontrol	-l [-c path] command [parameters ...]

DESCRIPTION
     The spdcontrol utility attempts to	query specified	Service	Discovery Pro-
     tocol (SDP) server.  Remote SDP servers are identified by their address.
     Connection	to the local SDP server	is made	via control socket.  The
     spdcontrol	utility	will use Service Search	Attribute Request and will
     print results to the standard output and error messages to	the standard
     error.

     The options are as	follows:

     -a	address
	     Connect to	the remote device with the specified address.  The
	     address can be specified as BD_ADDR or name.  If name was speci-
	     fied then the spdcontrol utility will attempt to resolve the name
	     via bt_gethostbyname(3).

     -c	path
	     Specify path to the control socket.  The default path is
	     /var/run/sdp.

     -h	     Display usage message and exit.

     -l	     Query the local SDP server	via the	control	socket.

     command
	     One of the	supported commands (see	below).	 Special command help
	     can be used to obtain the list of all supported commands.	To get
	     more information about specific command use help command.

     parameters
	     One or more optional space	separated command parameters.

COMMANDS
     The currently supported node commands in spdcontrol are:

	   Browse
	   Search

CAVEAT
     The spdcontrol utility only implements client side	functionality.

     The spdcontrol utility only requests the following	attributes from	the
     SDP server:

	   1.	Service	Record Handle
	   2.	Service	Class ID List
	   3.	Protocol Descriptor List
	   4.	Bluetooth Profile Descriptor List

DIAGNOSTICS
     The spdcontrol utility exits 0 on success,	and >0 if an error occurs.

SEE ALSO
     bluetooth(3), sdp(3)

AUTHORS
     Maksim Yevmenkin <m_evmenkin@yahoo.com>

FreeBSD	10.1		       September 7, 2003		  FreeBSD 10.1